1. When to change the HAYFLOW filter element?

Fluid through the filter medium creates a pressure drop across the system. This 
pressure increases as the element continues to trap contamination from the flow 
system. The pressure drop is the best indication of when to change the HAYFLOW 
element. 
Under normal circumstances and unless otherwise indicated on the datasheet, the
recommended maximum pressure drop should not exceed 2.5 bar (36 psi). The
optimal pressure drop and the frequency of element change-out can only be
determined by experience with each process. 

Tel.: +49/(0) 2486 809 400
Tel.: +33/(0) 4 72 78 84 50
Tel.: +44/(0) 1206 848 350 
Tel.: 0800 29 36 89 
Tel.: 800 78 58 83 
Tel.: 0800 77 0 22 
Tel.: 800 2 42 98 
Tel.: 0800022 27 03 
Tel.: 90098 49 15 
Tel.: +49/(0) 2486 809 470 
Tel.: +27/(0) 11 791 4331 

Fax: +49/(0) 2486 809 500
Fax: +33/(0) 4 78 74 43 07
Fax: +44/(0) 1206 848 359 
Fax: 0800 29 36 90 
Fax: 800 78 58 84 
Fax: 0800 77 0 23 
Fax. 800 2 42 99 
Fax: 0800 0 22 26 95 
Fax: 900 98 49 15 
Fax: +49/(0) 2486 809 570 
Fax: +27/(0) 11 791 0583 

Customer Service:

 

Germany 
France 
UK 
Austria 
Italy 
Belgium 
Luxembourg 
Netherlands 
Spain 
Export 
South Africa 

Tel.: +49/(0) 2486 809 0
Fax: +49/(0) 2486 809 800 
[email protected] 

www.filtration.eaton.com 

Headquarters EUROPE, MIDDLE EAST and 
AFRICA  
Eaton Filtration GmbH 

Auf der Heide 2 
D-53947 Nettersheim, Germany 

For further info or questions, please contact your Eaton Filtration representative. 

3. Starting up again 

Close the filter housing and start up the filtration process following the installation 
instructions supplied with the housing. 

Photo 4: 

Push the element with the instal-
lation tool down to the bottom of 
 the basket. 

Photo 1: 

Taking out the element. 

Photo 2: 

The lifting tool: Lifting 
up the basket. 

Photo 3: 

Insert the HAYFLOW installation 
tool in the element. 

2. Installing a new HAYFLOW filter element

 

 Preparing the housing 

 

1.  The filter housing has to be opened according to the installation and maintenance 
     instructions delivered together with the specific housing. 
2. Remove the used filter element from the basket (Photo 1). The element can be
  easily lifted from the basket by the handles of the SENTINEL

®

ring, at the cut 

 

handle in the centre sleeve or at both. Dispose of in an appropriate manner. 

3.  Clean the housing/basket if necessary, paying special attention to the O-rings and 
  sealing surfaces. With another tool the basket can be lifted up from the housing
 

until it can be taken out by hand (photo 2). Do not use this tool to carry the basket

 around. 
4.  Replace O-Rings of the housing when deformed or damaged with new O-Rings of 
 

 the correct material. 

 

 Installing your new HAYFLOW element 

 

1. Remove the label. Note: the label contains the batch and product code numbers
 

and should be retained as a reference. 

2. Insert the HAYFLOW installation tool into the element (photo 3) and push the 
 

installation tool down to the bottom of the element. 

3. Install the element with help of the installation tool into the basket. Push it down
 

until it sits at the bottom (photo 4). 

4. Remove the installation tool by pulling it out. 
5. Check that the SENTINEL ring sits properly on the machined seat (photo 5). 
6. See that every basket is fitted with a new filter element.