49
EATON
Heavy-Duty Series 2 Hydrostatic Pumps Parts and Repair E-PUPI-TS004-E October 2004
System Operating Hot
Troubleshooting
Fill to
Proper
Level
Replace
Transmission
(Pump & Motor)
Repair
or
Replace
Replace
Repair
or
Replace
Repair
or
Replace
Repair
or
Replace
Repair
or
Replace
Repair
or
Replace
Inspect Charge
Relief Valve
(At Pump)
Low in
Forward
or Reverse
Low in
Neutral,Forward
or Reverse
Inspect
Inlet
Filter
11
Inspect Motor
By−Pass Valve
(if Used)
10
Check Oil
Level in
Reservoir
7
Inspect
Charge
Pump
15
Ok
Below Level
Clean
Inspect
Heat
Exchanger
8
Clogged
Ok
Defective
Inspect Heat
Exchanger By−Pass
Valve (if Used)
9
Ok
Defective
Ok
Check
Charge
Pressure
Inspect Charge
Relief Valve
(At Motor)
14
Defective
Ok
Clogged
Ok
Inspect
IPOR Valve
(if Used)
Ok
Defective
Ok
Ok
Defective
Defective
13
Ok
16
Inspect
System Relief
Valves
4
Repair
or
Replace
Defective
Fault-Logic Tables