INSTALLATION

1.

   This fixture can be installed directly to a flat surface  

 

 

 

    or as a pendant with a 1/2 inch conduit fitting.  

 

 

 

    Splice connections can be made inside the fixture  

 

 

 

    housing. To gain access to the fixture housing  

 

 

 

    remove fixture back plate by removing the 4 #6 - 32  

 

 

 

    stainless steel screws on the back plate (Fig. 1).

2. 

  To wire the fixture connect the white supply wire to  

 

the white fixture wire using the included wire nut.  

 

Connect the black supply wire to the black fixture 

 

wire using included wire nut. Connect the supply  

 

ground wire to the fixture ground wire using included  

 

wire nut.

3. 

  If using the fixture housing for splice connections  

 

replace the fixture back plate using the Qty 4 #6-32  

 

stainless steel screws (Fig. 3). 

4. 

  Mount housing to either 1/2 in. hanging conduit 

or to a surface using the two tabs and mounting 

screws (sold separately).

5.  

Apply silicone caulk around the base of the housing 

or around the conduit to provide a watertight seal 

against rain and moisture.

NOTE:

 If you remove one of the 4 conduit plugs and use  

an alternate conduit location add thread sealing tape to  
plug to ensure water tight seal in new plug location.  
Ensure any unused conduit opening has a conduit plug.

CARE AND MAINTENANCE

1. 

 

Turn off power at main fuse or circuit breaker 

before installing or servicing.

2. 

  Loosen wire guard set screw using M2 allen  

 wrench.

3. 

  Rotate wire guard counter clockwise to remove wire  

 

guard (B) (Fig. 2).

4. 

  Rotate lens counter clockwise to remove glass  

 

lens (C).

5. 

  Remove any dirt/debri from lens and clean lens with  

 

glass cleaner or soap and water.

6. 

  Remove any water/residue from lens with dry cloth.

7. 

  Replace glass lens.

8. 

  Replace wire guard.

9. 

  Tighten wire guard set screw.

NOTE:

 If lens is replaced, use only tempered safety 

glass of equal thickness per UL requirements.

PACKAGING CONTENTS/CONTENIDO DEL PAQUETE/ CONTENU DE L’EMBALLAGE

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•  Flat head screwdriver
•  Mounting screws
•  Weatherproof silicone caulk

IMPORTANT SAFETY INSTRUCTIONS

  When using product, basic precautions should always be followed, including the following:

•  Heed all warnings, including below warnings AND those included on product

 NOTE:

 Failure to follow instructions may result in improper operation or void the warranty. 

 
 

•  Read and follow these instructions
•  cULus Listed for wet location use
•  Disconnect at fuse or circuit breaker before installing or servicing
•  Edges may cut. Handle with care

CAUTION

•  Connect fixture to a 120 - 277V, 50-60 Hz power source. Any other connection      

            voids the warranty

•  Fixture should be installed by persons with experience in household wiring or by a 

qualified electrician. The electrical system, and the method of electrically connecting 

the fixture to it, must be in accordance with the National Electrical Code and local 

building codes

•  For wall or ceiling mount application
•  FOR SUPPLY CONNECTIONS, USE WIRE RATED FOR AT LEAST 75°C

•  This device complies with Part 15 of the FCC Rules. Operation is subject to the  

following two conditions: (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference that may cause 

undesired operation   
     

WARNING: FCC Regulations state that any unauthorized changes or  

modifications to this equipment not expressly approved by the manufacturer 
could void the user’s authorization to operate this equipment.

 

SAVE THESE INSTRUCTIONS AND WARNINGS

WARNING: Risk of electric shock. Disconnect power at fuse or circuit breaker before 

installing or servicing.
NOTE:

 Make certain that the fixture is connected to a 120 - 277V power source.  

 

UL-approved wire connectors should be used. Be sure no loose strands of wire are sticking 

out from under your wire connectors.

VT1730

VT1730IH

A.

  Fixture housing

 Luminaria
  Boîtier du luminaire

 

ENGLISH

B.

 Guard

  Protección
 

Protecteur

C.

  Glass lens 

  Lente de vidrio
  Lentille en verre 

Fig. 1

WARNING

D.

  Wire Connectors

  Raccords de fils
  Conectores del cable

Fig. 2

1/2 inch threaded

conduit openings

Guard

set

screw

Fig. 3

1. Remove

set screw
2. Remove

wire guard

3. Remove

glass lens

Summary of Contents for HALO VT1730

Page 1: ...RED Purchase separately Phillips screwdriver Flat head screwdriver Mounting screws Weatherproof silicone caulk IMPORTANT SAFETY INSTRUCTIONS When using product basic precautions should always be followed including the following Heed all warnings including below warnings AND those included on product NOTE Failure to follow instructions may result in improper operation or void the warranty Read and ...

Page 2: ...accordement annule la garantie Le luminaire doit être installé par des personnes ayant l expérience du câblage domestique ou par un électricien qualifié Le système électrique et la méthode de raccordement électrique du luminaire doivent être conformes au Code national de l électricité et aux Codes du bâtiment locaux Pour un montage mural ou au plafond POUR LES CONNEXIONS D ALIMENTATION UTILISEZ UN...

Page 3: ...ignalé immédiatement au transporteur effectuant la livraison et une réclamation doit être adressée à ce dernier La reproduction de ce document est strictement interdite sans l autorisation préalable par écrit de Eaton a reproduction de ce document est strictement interdite sans l autorisation préalable par écrit de Eaton Pour assistance appelez le 1 800 334 6871 ou envoyez nous un courriel à consu...

Page 4: ... instalados o utilizados junto con los productos Eaton Los daños del producto causados por bombillas de reemplazo corrosión o decoloración de los componentes de latón no están cubiertos por esta garantía LIMITACIÓN DE RESPONSABILIDAD EATON NO SERÁ RESPONSABLE LEGAL EN NINGÚN CASO DE DAÑOS INDIRECTOS ACCIDENTALES O RESULTANTES SIN IMPORTAR LA ACCIÓN LEGAL YA SEA POR CONTRATO RESPONSABILDIAD ESTRICT...

Reviews: