2
Fig. 1
F
F
D
A
INSTALLING THE BULB
1.
Screw the bulb (C) securely into socket.
2.
Back the bulb (C) out one or two turns, then screw bulb (C) back to insure proper position
in socket.
3.
Turn power back ON.
TROUBLESHOOTING
Problem
Cause / Solution
Light Does
Not Come On
Or Light Comes
On For Only A
Few Seconds
No power to the fixture.
• Check if circuit breaker tripped.
• Confirm wall switch is ON.
Bulb is not seated properly.
• Refer to “Installing Your Bulb” instructions.
Bulb is faulty.
• Replace bulb.
Sensor is not working properly.
• Check if light is being reflected into the sensor, causing the
fixture to turn OFF.
Wiring to the unit is loose.
• Confirm wiring is properly secured.
Caution: Turn off power before checking.
Light Does Not
Shut Off During
Daytime
Light sensor is not receiving enough light to trigger switch.
• Shine a flashlight into the light sensor for 2-3 minutes. The
fixture should switch OFF after two minutes This means the
sensor is not receiving enough light.
Light Cycles
On and Off
Light sensor is receiving too much reflected light.
• Cover light sensor with a piece of black electrical tape. The
fixture should turn ON after a slight delay. This means that
extraneous or reflected light from the fixture is causing the
sensor to turn the unit OFF. Install fixture where there is no
reflective light.
Bulb is faulty.
• Replace bulb.
2-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Eaton warrants to customers that, for a period of two years from the date of purchase,
Eaton products will be free from defects in materials and workmanship. The obligation of
Eaton under this warranty is expressly limited to the provision of replacement products.
This warranty is extended only to the original purchaser of the product. A purchaser’s receipt
or other proof of date of original purchase acceptable to Eaton. This is required before
warranty performance shall be rendered. This warranty does not apply to Eaton products that
have been altered or repaired that have been subjected to neglect, abuse, misuse or accident
(including shipping damages). This warranty does not apply to products not manufactured by
Eaton which have been supplied, installed, and/or used in conjunction with Eaton products.
Damage to the product caused by replacement bulbs or corrosion or discoloration of brass
components are not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL EATON BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT,
STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL
THE LIABILITY OF EATON FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED
WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR
MODIFICATION OF EATON PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE,
EXCEED THE PURCHASE PRICE OF EATON PRODUCTS GIVING RISE TO A CLAIM. NO LABOR
CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
To obtain warranty service, please contact Eaton, at 1-800-334-6871, press option 2 for
Customer Service, or via e-mail [email protected] and include the following
information:
• Name, address and telephone number
• Date and place of purchase
• Catalog and quantity purchase
• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number issued
by the Company and must be returned freight prepaid. Any product received without a Return
Goods Authorization Number from the Company will be refused. Eaton is not responsible for
merchandise damaged in transit. Repaired or replaced products shall be subject to the terms
of this warranty and are inspected when packed. Evident or concealed damage that is made
in transit should be reported at once to the carrier making the delivery and a claim filed with
them.
Reproductions of this document without prior written approval of Eaton are strictly prohibited.
For assistance, call 1-800-334-6871 or e-mail us at [email protected]
Printed in China
ARTICLES REQUIS
(à acheter séparément)
• Tournevis cruciforme
• Clé à molette
• Perceuse avec foret de 4,8 mm (3/16 po)
• Conduit souple de 12,7 mm (1/2 po) de diamètre (la longueur est selon l’installation)
• Raccords de conduit de 12,7 mm (1/2 po)
• Capuchons de connexion
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ
Lorsque vous utilisez le produit, suivez toujours les consignes de sécurité suivantes :
• Veuillez lire et suivre ces directives.
• Respectez tous les avertissements,
• y compris les avertissements ci-dessous ET ceux inclus sur le produit.
• Veuillez conserver ces directives et ces avertissements.
• Pour utilisation à l’extérieur seulement.
• Homologué C-UL US pour utilisation à des endroits mouillés.
• Couper le courant et laisser le luminaire refroidir avant de changer l’ampoule ou de
toucher le luminaire.
• Les bords peuvent être coupants. Manipulez avec précaution.
REMARQUE : Les ampoules contiennent du mercure. Jetez en respectant les lois lo-
cales, provinciales ou fédérales. Pour obtenir plus de détails, visitez le site : www.
lamprecycle.org.
PRÉCAUTION
• Raccorder l’appareil d’éclairage à une alimentation 120 V, 60 Hz. Toute autre
connexion annule la garantie.
• L’appareil d’éclairage doit être installé par un électricien ou une personne chevronnée
en câblage domestique. Le système électrique et la méthode de connexion électrique
de l’appareil d’éclairage doivent être conformes au Code national de l’électricité et aux
codes locaux du bâtiment.
• Utilisez toujours une ampoule de même type et de même puissance que celle qui
est comprise avec le dispositif. L’utilisation d’une ampoule inadéquate annulera
la garantie.
• Si le luminaire est installé à l’envers, cela peut engendrer une surchauffe ou une ac
cumulation d’eau. Installez-le à l’endroit.
• FILS D’ALIMENTATION DE 90˚C MINIMUM.
• Cet appareil est conforme au chapitre 18 des règlements FCC.
MHz./Ce produit peut produire des interférences à l’équipement radio et ne doit pas
être installée près de l’équipement de communication navale de sécurité, des bateaux
sur l’eau ou autres équipements nautiques vitaux ou équipements de communications
utilisant une fréquence de 0,45 à 30 MHz.
MONTAGE DU LUMINAIRE
REMARQUE
: Ce luminaire a été conçu pour être
connecté par conduit à une boîte de jonction en métal à l’épreuve des intempéries
(non inclus) bien installée et mise à la terre correctement. Tous les connecteurs,
conduits et boîtes de jonction (non inclus) doivent être homologués pour les
endroits mouillés.
1.
À l’aide de la matrice sur la boîte, marquer et percer
les trous de montage.
Remarque :
Fixez le luminaire en position verticale.
2.
Installer les deux vis de montage (E) du bas en
premier en laissant assez de place entre les vis
de montage et la surface pour le montage
du luminaire.
3.
Visser la vis de montage (E) supérieure dans l’avant
trou et retirer la vis. Cela fera un filetage
dans le trou et facilitera l’installation du luminaire.
4.
Sortez le cache d’accès (D) du sac de pièces.
5.
Installer le premier connecteur de conduit et le
conduit (non inclus) dans le couvercle d’accès (D).
6.
Faites passer les fils d’alimentation dans le conduit
et effectuez le câblage comme indiqué dans la
section « Câblage du luminaire ».
7.
Fixer le couvercle d’accès (D) au luminaire (A)
à l’aide des vis de montage du couvercle d’accès
(F) (Fig. 1).
Remarque :
Assurez-vous que l’ensemble du câblage est dans le
bras avant de resserrer les vis du cache d’accès (F).
8.
À l’aide des trois vis de montage (E) fournies,
fixer le boîtier (A) à la surface de montage.
FRANÇAIS
AVERTISSEMENT