Installation Instructions

Model # ONW-D-1001-MV-W

Model # ONW-D-1001-MV-V

Model # ONW-D-1001-MV-LA

Model # ONW-D-1001-MV-G

Model # ONW-D-1001-MV-B

NeoSwitch Dual Technology Single Relay

Occupancy Sensing Wall Switch

(Ground Required)

•  Read all instructions on both sides of this  

sheet first

•  Install in accordance with ALL local codes
•  For indoor use only

General Information  

Technology:

 Passive Infrared (PIR) and Ultrasonic (US)

Electrical Ratings:

120 VAC:

•  Incandescent/Tungsten –  

Max. load: 6.7 amps, 800W, 50/60 Hz

•  Fluorescent/Ballast –  

Max. load: 10 amps, 1200W, 50/60 Hz

Motor Load: ¼ HP @ 125 VAC
277 VAC:

•  Fluorescent/Ballast –  

Max. load: 9.8 amps, 2700W, 50/60 Hz

Ballast Compatibility:

 Compatible with magnetic and 

electronic ballasts

No Minimum Load Requirement
Time Delays:

 Self-Adjusting, 15 seconds/test (10 min 

Auto), Selectable 5, 15, 30 minutes

Coverage:

 Major motion – 1000 sq. ft. 

 

Minor motion – 300 sq. ft.

Light Level Sensing:

 0 to 200 foot-candles

Operating Environment:

•  Temperature: 32° F – 104° F (0° C – 40° C)
•  Relative Humidity: 20% to 90% non-condensing

Housing:

 Durable, injection molded housing. ABS resin 

complies with UL 94VO.

Size:

•  Mounting Plate/Strap Dimensions: 

4.195" H x 1.732" W (106.553 mm x 44 mm)

•  Product Housing Dimensions: 2.618" H x 1.752" 

W x 1.9" D (66.5 mm x 44.5 mm x 48.26 mm)

LED Indicators:

 Red LED indicates PIR detection; 

Green LED indicates Ultrasonic detection.

Specifications  

Description  

Coverage  

The ONW-D-1001-MV Occupancy Sensing Wall Switch is a Passive Infrared (PIR) and Ultrasonic (US) motion 

sensing lighting control and conventional wall switch all-in-one, used for energy savings and convenience.

The sensor combines PIR and US technologies to monitor a room for occupancy.

PIR Technology

The sensor’s segmented lens divides the field of view into sensor zones, and detects the changes in temperature 

that are created when a person, or part of a person as small as a hand, passes into or out of a sensor zone.

US Technology

The sensor produces a low intensity, inaudible sound. It detects occupancy from changes in the acoustic waves 

caused by motion, such as reaching for a telephone, turning a page in a book, walking into a room, turning in a 
swivel chair, etc. The sensor does not respond to audible sound.

Dual Technology sensors ensure the greatest sensitivity and coverage for tough applications thus saving additional 

energy. PIR is used to turn the lights ON and then either or both technologies are used to keep the lights ON.

The ONW-D-1001-MV allows the control of one load with one occupancy sensor switch.
The sensor can be configured to enhance energy savings by setting the unit for Manual ON operation.
In Automatic ON Mode, the lights turn ON automatically when a person enters the room. In Manual ON Mode, the 

lights are turned ON by pressing the universally recognized light icon pushbutton. In either mode, the lights stay ON 
as long as the sensor detects motion in the room. When the room is vacated, the lights turn OFF automatically after a 
preset time delay interval.

The sensor includes self-adaptive technology that continually adjusts to conditions by adjusting sensitivity and time 

delay in real-time. By adjusting sensitivity and time delay automatically, the sensor is maximizing the potential energy 
savings that are available in the particular application.

The Daylighting feature prevents lights from turning ON, when the room is adequately illuminated by natural light.
Walk-Through feature maximizes energy savings by not leaving the lights ON after a momentary occupancy. The 

sensor will switch the lights ON when it detects a person entering the area. If the sensor does not continue to detect 
motion 20 seconds following the initial activation, it will automatically go to a shorter 2 minute time delay.

ON/OFF Button Disable Option – When selected this option disables the ON/OFF button(s) and sensor becomes 

automatic only control.

The ONW-D-1001-MV is designed for offices up to 300 square feet.

Location  

When installing the ONW-D-1001-MV in a new junction box, choose the switch location carefully to provide optimum 

coverage of the occupied area. When replacing an existing wall switch, bear in mind that there must be a clear line-
of-sight between the sensor and the area to be covered. Avoid pointing the ONW-D-1001-MV directly into the hallway 
where it may detect passers-by.

Installation  

Wiring  

CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned 

OFF at the branch circuit breaker. According to NEC  240-83(d), if the branch circuit breaker is used as the 

main switch for a fluorescent lighting circuit, the circuit breaker should be marked “SWD.” All installations 

should be in compliance with the National Electric Code and all state and local codes.

NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is 

shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the 

effects of cycling.

1. Make sure power is turned OFF at the branch circuit breaker.

2. Wire units as shown in wiring diagrams per applicable voltage requirements. (Use twist-on wire connectors for 

all connections.)

3. Mount unit to wall box.

4. Turn power back ON at the branch circuit breaker and wait 2 minutes for the unit to stabilize.

5. Make necessary adjustments. (See Checkout and Adjustments section)

6. Install wall switch plate.

LOAD

120/277 VAC

BLACK

BLUE

NEUTRAL

GROUND

GREEN

Wiring Diagram 1:

120/277 VAC single level

single circuit wiring diagram

LOAD 1

120/277 VAC

BLACK

BLUE

NEUTRAL

GROUND

GREEN

LOAD 2

A/B SWITCHING USING TOGGLE 

SWITCH TO TURN OFF SECOND LOAD

Wiring Diagram 2:

120/277 VAC single level 

switch dual level wiring using a 

toggle switch wiring diagram

,

36

8

,

Minor Motion, IR

Major Motion, IR

20

,

Maximum coverage area may

vary somewhat according to room

shape and the presence of obstacles.

The NEMA WD 7 Guide and robotic

method were utilized to verify

coverage patterns.

Minor Motion, Ultrasonic

Major Motion, Ultrasonic

,

10

8

,

,

15

20

,

P/N 9850-000323-01

The ONW-D-1001-MV can be installed in any standard single gang box. It may be 

installed in the same manner as an ordinary wall switch.

•  Wire the ONW-D-1001-MV as described in the wiring section
•  Mount the ONW-D-1001-MV in the junction box