background image

 

 

 

 

 

 

TECHNICAL 
DOCUMENTATION

 

 

 

 

NON-CONTRACTUAL PICTURES | DOC. VERSION 19012021

 

Opening the charging station and any changes to the configuration must be done by a qualified electrician and must comply with local regulations 
and laws for safety in the use of electricity. Failure to comply with the regulations in this manual will result in the end the warranty period.  

 

 

Summary of Contents for GREEN MOTION RANGE XT66

Page 1: ...the charging station and any changes to the configuration must be done by a qualified electrician and must comply with local regulations and laws for safety in the use of electricity Failure to comply with the regulations in this manual will result in the end the warranty period ...

Page 2: ...2 3 Wiring 10 3 COMMISSIONING 12 3 1 Opening the Range XT 66 housing 12 3 2 Electrical connection 13 3 3 Charging station configuration 14 3 4 Emobility Cockpit connection 15 4 USAGE OF THE STATION 18 4 1 Description of the station 18 4 2 Sockets and Cables 19 4 3 Charging states 19 5 MAINTENANCE 22 5 1 Troubleshooting 22 5 2 Cleaning or replacing the filters 23 5 3 Support 24 ...

Page 3: ... of access RFID App SMS Scan Charge Network interface Ethernet cable 3G 4G 5G Remote management Software management system eMobility Cockpit online ENVIRONMENTAL Operating temperature 25 C to 45 C Altitude Up to 2000 m 6500 ft Setting Floor mount Humidity 95 relative humidity MECHANICAL Dimensions 1705 x 833 x 263mm Weight 180 kg Housing material Stainless steel Cooling Fan cooling Cable length 5 ...

Page 4: ...essary take precautions to have a free air flow and to prevent snow or objects from blocking the inlet and outlet The cable support shall be mounted at a height comprised between 1 and 1 1m from the ground level for optimal accessibility It can be mounted freely to the right or the left side of the charging station depending upon site configuration and user preferences considered the 300mm free sp...

Page 5: ...RANGEXT 66 TECHNICAL DOCUMENTATION Page 5 Front view Bottom view ...

Page 6: ...g Fix the column on the concrete base with 4 threaded rods M10 according to the following diagram Do not forget the flat washers Concrete base 800 x 450 x 250 mm The Ethernet cable must come out at least 2 meters from the concrete base Fixation point Electrical cable ...

Page 7: ...RANGEXT 66 TECHNICAL DOCUMENTATION Page 7 Fixation point can be accessed via a removal trap door on the sheet metal casing Fixation point ...

Page 8: ...RANGEXT 66 TECHNICAL DOCUMENTATION Page 8 Lifting Anchor ...

Page 9: ...ble information on the placement of the Range XT 66 charging stations with respect to parking spaces Optimal placement As show in the figure here below we recommend installing the Range XT 66 front and center of the parking space and each charging station should serve one parking space Range XT 66 Range XT 66 Range XT 66 Range XT 66 Range XT 22 Range XT 66 Range XT 22 1 2 3 Range XT11 22 Range XT1...

Page 10: ...to the Mains Grid there is no need of Earth Fault Current Breaker 1 These sections must be re assessed by the installer according to the length 2 The Installer must define the types of Circuit breaker The circuit breakers at panel of 125 A and the power cable minimal cross sections 50 mm2 are overvalued in order to ensure the functioning of the charging station with a temperature increase NOTE FOR...

Page 11: ...RANGEXT 66 TECHNICAL DOCUMENTATION Page 11 Circuit diagram Connection Diagram ...

Page 12: ...x can lead to electric shock hazards Please make sure to carefully read instructions In case of a doubt please immediately contact Green Motion support 3 1 Opening the Range XT 66 housing Use a M3 Imbus screwdriver to unscrew the 6 screws located on the top and the bottom right side of the Range XT front door The front door can be opened sideway The screw torque shall not exceed 3 nm Electric shoc...

Page 13: ... station In any case working under voltage shall be avoided The electrical cable must reach the terminal from the left The electrical cable and the communication cable can be introduced into the Range XT housing from the bottom left side 1 The electrical connection is made on the power supply terminals located at the bottom left of the charger Please measure the rotating field and the line voltage...

Page 14: ...GMCU MPb board The board is located on the door of the converter enclose in front of the screen JP1 CAN Termination 66kW configuration shall only be used on 66kW chargers S2 OFF ON 1 Offline Online Offline Online 2 RFID Reader No Yes 3 CAN slave No Yes 4 AC DC AC DC 5 CCS Combo No Yes 6 CHAdeMO No Yes 7 DC 66kW No 66kW 8 AC T23 No Yes JP1 S2 ...

Page 15: ... router is located on the Range XT door Router Configuration The configuration is performed on the Green Motion Manufacturing Plan Teltonika RUTX09 modem router configuration Default settings IP 192 168 1 1 User admin Password admin01 The router requires a password change during the first start Please contact Green Motion SA support for the password ...

Page 16: ... 168 52 1 If a step by step configuration menu Setup Wizard appears you must ignore it and go directly to the menus described below Go to the Network WAN menu Activate and edit the MOB1S1A1 network If necessary enter the APN and the PIN code of the SIM card APN shared m2m ch Press Save Apply Please contact Green Motion SA support for the password ...

Page 17: ...pears it must be closed Go to the Network WAN menu Activate the WAN network and deactivate the other networks Press Save Apply o Authorize the management of the router from the WAN Only if in a private network Go to System Administration Access control Check Enable Remote HTTP and Enable Remote HTTPS Please contact Green Motion SA support for the password ...

Page 18: ...en display 3 RFID reader 4 LED display 5 Emergency stop button To start a charge simply connect the car to the appropriate socket To switch on the Model either via the button offline charging station via the RFID card offline and online via the mobile app online stations only or via a SMS online stations only Ç Ç ...

Page 19: ...When you have authenticated on the Range XT 44 for the CHAdeMO plug you must select the plug icon on the screen it is mandatory Plug type icon shows as below CCS EU CHAdeMO 4 3 Charging states Button indicator Button Status display Comments No light Not powered or start up stage Green light on Ready to be use or need user interaction Blue light on Charge initialization vehicle charging or charge f...

Page 20: ...ments Green light on Ready to be use Flashing green light Start up stage Breathing green light Waiting for user interaction Flashing blue light Charge start up stage Breathing blue light Vehicle in charge Blue light on Vehicle charged Red light on Error in charging No light Stopped or not powered 50 of charge 100 of charge 50 100 ...

Page 21: ... to operate In this section you will find the information to start your experience LED Display status display Splash screen Touch the screen to wake up Authentication screen Before any operation please ensure that the 4G sign is colored in blue If bar graph is RED there is no connection to the server By touching the Flag you can choose your language Present the RFID badge on the RFID reader to ini...

Page 22: ...arging station visual indicators are red Try to disconnect the car from the charging station and retry Check the emergency button it should be pull out Antenna bar graph is red Check that the connection of the Range XT to the backend is available network is available Authentication refused Check that you are a recognize and authorized user subscribed to the charging point operator database Check t...

Page 23: ...filters are checked on a yearly basis to ensure they are not obstructed and working properly In case of obstruction filters need to be replaced immediately Filters can be replaced They are accessible as described below Using a 2 5 mm hex key remove the 2 screws attaching each filter cartridge to the unit The filters are located inside the filter cartridge Contact Green Motion support for spare fil...

Page 24: ...pport is available Monday to Friday from 08 00 to 12 00 and from 13 00 to 17 00 16 00 on Friday CET Email support greenmotion ch Tel 41 21 544 04 46 Green Motion Ltd Chemin de Maillefer 61 1052 Le Mont sur Lausanne Switzerland GreenMotionEV com info greenmotion ch 41 0 21 544 04 44 ...

Reviews: