8
ENGLISH
6. Operation
Battery charge
The UPS charges the battery as soon as it is connected to the AC outlet, whether button
6
ispressedornot.Whenusedforthefirsttime,thebatterywillonlyprovideits
maximum performance after it has been charged for 8 hours. It is recommended that
the UPS be permanently connected to the AC power supply to ensure the best possible
performance.
Switching-on the UPS
Press button
6
for about 1 second.
Surge protection outlets 18
without battery backup
Equipment connected to these outlets is supplied as soon as the AC cord
4
is plugged
in. They are not affected by button
6
.
Battery backup outlets
19
Equipment connected to these outlets is supplied as soon as button
6
turns green
(seefigureD).
These outlets can be turned on even if the UPS is not connected to AC power
(button
6
flashes).
5. UPS setting through the LCD
l
LCD shut off if no activity for 3 minutes.
5s
2s
2s
2s
2s
(165 - 264 V)
Output voltage
Input voltage
tolerance
EcoControl
Alarm
(150 - 284 V)
Release scroll down button to select menu
Save the new value
10s
5s
5s
Example of setting
Скачано
с
сайта
интернет
магазина
https://axiomplus.com.ua/