Eaton ELC-CADNET Instruction Sheet Download Page 5

- 4 - 

Environment   

Operation: 0°C ~ 55°C (temperature), 50 ~ 95% (humidity), 
pollution degree 2;   
Storage: -25°C ~ 70°C (temperature), 5 ~ 95% (humidity) 

Vibration/ Shock 
Resistance 

Standard: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & 
IEC 68-2-27 (TEST Ea) 

Certificates 

 

 

 Installation 

How to connect extension modules to the ELC-CADNET: 

1.  Adjust the extension clip on the right side of the ELC-CADNET. 

2.  Line up the extension port of the ELC-CADNET with extension module 

and connect them as the figure shown below. Fasten the extension clip. 

3.  The  colors  on  the  pins  on  the  DeviceNet  connection  port  match  the 

colors of the DeviceNet cable. Make sure you connect the cable to the 
right pins. 

E

L

C

-

C

A

D

N

E

T

E

L

C

-A

N

0

6

A

A

N

N

E

L

C

-

A

N

0

4

A

N

N

N

L

N

24V

0V

ELC-

PS01

 

E

L

C

-A

N

0

6

A

A

N

N

E

L

C

-

A

N

0

4

A

N

N

N

E

L

C

-

C

A

D

N

E

T

 

 Configuration 

1. The  DeviceNet  master  sends  the  output  data  to  the  ELC-CADNET, 

which in turn sends it to the output modules. 

2. ELC-CADNET  sends  the  input  data  from  the  input  modules  to  the 

DeviceNet master. 

Connection Example: 

DeviceNet

ELC-PV28

ELC-CODNETM

ELC-CO DNETM

ELC-PV28

RU N

STOP

Master

E

L

C

-A

N

0

2

N

A

N

N

E

L

C

-E

X

0

8

N

N

S

N

E

L

C

-E

X

1

6

N

N

D

R

E

L

C

-C

A

D

N

E

T

E

L

C

-A

N

0

4

A

N

N

N

E

L

C

-T

C

0

4

A

N

N

N

E

L

C

-P

T

0

4

A

N

N

N

 

Summary of Contents for ELC-CADNET

Page 1: ...Eaton Logic Controller DeviceNet Distributed I O Adapter Module INSTRUCTION SHEET Applicable Distributed I O Adapter Module ELC CADNET IL05004007E 002 1214120 02 2010 12 10 5011697801 ECD1...

Page 2: ...dust humidity and vibration DO NOT disconnect equipment unless power has been switched off or the area is known to be non hazardous DO NOT connect AC power to any of the DC input output terminals as i...

Page 3: ...N_L Blue Signal 3 SHIELD Shielded cable 4 CAN_H White Signal 5 V Red 24VDC Address Setup Switch Settings Description 9 1 6 4 5 0 0 9 1 3 2 7 8 2 5 6 4 3 7 8 00 63 Valid DeviceNet node address 64 99 In...

Page 4: ...ud rate 125kbps 250kbps 500kbps RS 485 Communication Port Type Removable 3 pin connector Transmission cable 2 twisted isolation cables Transmission speed 1 200 2 400 4 800 9 600 19 200 38 400 57 600 1...

Page 5: ...ow Fasten the extension clip 3 The colors on the pins on the DeviceNet connection port match the colors of the DeviceNet cable Make sure you connect the cable to the right pins E LC C AD N E T E LC A...

Page 6: ...byte of the contents of CH1 for the ELC AN04ANNN D6033H High byte of the contents of CH2 for the ELC AN04ANNN D6033L Low byte of the contents of CH2 for the ELC AN04ANNN D6034H High byte of the conten...

Page 7: ...CADNET Slave ELC CODNETM Digital Analog Extension Module D6282H ELC CADNET control word High byte of the control word in ELC CADNET D6282L Low byte of the control word in ELC CADNET D6283H Analog Exte...

Page 8: ...D6040L Low byte of the contents of CH4 for the ELC TC04ANNN D6041H High byte of the contents of CH1 for the ELC PT04ANNN D6041L Low byte of the contents of CH1 for the ELC PT04ANNN D6042H High byte o...

Page 9: ...eNet specification 3 Check if the data rates for all devices on the network are the same 4 Check if the node address of ELC CADNET is a valid address 5 Check that there is proper network power 24vdc a...

Page 10: ...or low voltage is detected by ELC CADNET 1 Check the power of ELC CADNET 2 Acquire relevant diagnosis information from the DNetConfig software Red light on Fatal error occurred due to invalid configu...

Reviews: