ea
s
ySafety internal
618
02/16 MN05013001Z EN
Diagnostics-/-Error codes
Table 31:
Diagnostic /Failure code, sorted by status number
Status number
Plain text
Hexadecimal (0–F)
decimal (0-9)
0000
0000
No Enable.
2001
8193
Enable issued; waiting for first (or only) input.
2002
8194
Waiting for second input.
2003
8195
Waiting for rising edge at Reset.
2004
8196
Waiting for falling edge at Reset.
2005
8197
Only one channel has been opened.
2007
8199
Waiting until feedback circuit closed.
2009
8201
Measurement started.
200A
8202
Operating mode can be selected.
200B
8203
Waiting for decreasing trigger signal; output not
active.
200C
8204
timing element running, output not active.
200D
8205
Timer stopped; output not active.
200E
8206
Waiting for inputs during startup testing.
2011
8209
Foot switch not operated (position 1).
2012
8210
Enable switch in OFF position
2013
8211
Foot switch in panic position (position 3).
2014
8212
Undefined foot switch position
2015
8213
Waiting for activation of guard locking.
2016
8214
Two-hand pushbutton in normal position.
2017
8215
Two-hand pushbutton 1: undefined position.
2018
8216
Two-hand pushbutton 2: undefined position.
201A
8218
Activate test signals
201B
8219
Check test signals T1 and T2 Off
Summary of Contents for easySafety