easy800/MFD control
commands
226
09/10 MN05013007Z-EN
Table 140:
Operand overview
Table 141:
Index 0 – Bit IO
Table 142:
Index 1 - Mode
Index
(hex)
Operand
Read
ing
Writing
00
Bit IO,
x
01
Mode,
x
02
Input value:
Operand to be converted
I1
x
c
1)
03
Output value:
contains the conversion
result
QV
x
1) The value can only be written if it is assigned to a constant in
the program.
h
The data for index 2 and 3 is transferred as a 32-bit value
in Intel format (Data 1 – Low Byte to Data 2 – High Byte).
Bit 7
6
5
4
3
2
1
0
FB output Data 3
–
–
–
–
–
–
–
EN
1)
1) Activates the function block on status 1.
Data 1
(hex)
00
BCD
Converts a BCD-coded decimal value to an
integer value
01
BIN
Converts an integer value to a BCD coded
decimal value