Periodic maintenance requirement

Periodic maintenance is required to ensure sensors perform to expectation, given the range of possible 

operating conditions they can face. Semiannually, a standard 4130 steel target in the size shown in 

the table below should be used to verify the “Maximum Sensing Distance” for every sensor. See the 

table below for standard target sizes and rated maximum sensing distances. This measurement must 

also consider the temperature in the sensing environment and account for the possibility of up to 10% 

temperature drift as shown in the table below. Any sensor that fails this periodic Maximum Sensing 

Distance test should be immediately replaced.

Specifications

AC 2-wire

DC 4-wire

Small (0.5 inch)

Large (1.0 inch)

Large (1.5 inch)

Small (0.5 inch)

Large (1.0 inch)

Large (1.5 inch)

Operating voltage

65–130 Vac 60 Hz

10–30 Vdc

Load current (resistive)

1.25 A rms

250 mA

Load current (inductive)

Make: 10 A rms for 3 cycles

Break: 1.25 A rms

250 mA 

0.10 A lamp load

Burden current/burden resistor

Burden resistor may be required for some 2-wire input applications 

(example: PLC use)

<50 mA

Minimum load

15 mA rms

N/A

Off-state leakage

<4 mA

<300 uA at 35 Vdc

Voltage drop

<4 Vac

<1.5 Vdc

Cable

MIL-C-24643/43, type LS2SJ-16 2 conductor w/shield

20-foot length

MIL-C-24643/43, type LS4SJ-20 4 conductor w/shield

20-foot length

Circuit protection

Overload protection to 6 A rms

Overload, short circuit, reverse polarity

Dielectric withstand

1000 Vac between case and each conductor

>60 seconds, <1.5 mA

250 Vdc between case and each conductor

>60 seconds, <0.75 mA

Outputs

Normally open or normally closed (by model)

1 x normally open, 1 x normally closed

Standard target size (4130 steel)

3 inch square,

0.062 thick

4 inch square,

0.062 thick

4 inch square,

0.062 thick

3 inch square,

0.062 thick

4 inch square,

0.062 thick

4 inch square,

0.062 thick

Head-on sensing range

0.5 ± 0.05 inch

1.0 + 0.22 inch  

– 0.08 inch

1.5 + 0.50 inch  

– 0.12 inch

0.5 ± 0.05 inch

1.0 + 0.22 inch  

– 0.08 inch

1.5 + 0.50 inch  

– 0.12 inch

Hysteresis

5–20%

5–30%

5–40%

5–20%

5–30%

5–40%

Weight

<5 lb

<6 lb

<6 lb

<5 lb

<6 lb

<6 lb

Response time

<50 msec

Switch stabilization

<500 msec

Operating temperature

–20 to 70 °C (–4 to 158 °F)

EMC

MIL-STD-461G (RS103 at 200 V/m) above deck usage (see Note)

Enclosure rating

NEMA 4, 4X, 6, 6P IP67, IP68

Approvals

MIL-PRF-24711B

Indicator LED (selected models)

Target present - LED on, target absent - LED off, internal fault - slow blink, external fault - fast blink

Vibration

MIL-STD-167-1, Type 1

Shock

MIL-S-901, Grade A, Type A, Class I lightweight equipment

Humidity

MIL-STD-202, Method 103B, test condition B

Materials of construction

316 stainless steel base, PA66 cover

Patents

Covered by US patent 7,296,485 and EU patent 1728058 B1. Other patents pending.

ote: 

N

All units referenced in this document meet the requirements of MIL-STD-461G CS114 with the exception of DC 

models under certain specific conditions. DC models meet the requirements of the bulk cable injection test under all 

conditions, above and below deck, but do not meet the requirements when the power conductor is tested individually 

above deck, outside of a shielded junction box, over the 2 MHz–30 MHz frequency range.

Summary of Contents for E56M

Page 1: ...NC on DC models and output fault status indicator LEDs on applicable models Sensors are available in four wire DC and two wire AC versions Basic operation A proximity sensor generates a sensing field in the vicinity of the face of the sensor When a metal object enters this field it disturbs the field in a way that is recognized by a detector circuit which then energizes the sensor output E56 High ...

Page 2: ...es and 4130 steel target material Sensing range will decrease if a target is used that is smaller than the standard target size See the table below for standard target sizes for each size sensor Sensor type Sensor size baseplate Standard target size Small 4 0 inches 3 x 3 inches 0 062 inch thick Large 1 0 inch range 5 0 inches 4 x 4 inches 0 062 inch thick Large 1 5 inch range 5 0 inches 4 x 4 inc...

Page 3: ...e Protection features Built in overload and short circuit protection prevents damage to sensors when the load current exceeds a safe level and DC models are additionally protected against reverse polarity Protection levels are shown in the specification table in this manual For sensor versions with LEDs the LED indicator will flash if the overload or short condition persists and the cycle will rep...

Page 4: ...S4SJ 20 4 conductor w shield 20 foot length Circuit protection Overload protection to 6 A rms Overload short circuit reverse polarity Dielectric withstand 1000 Vac between case and each conductor 60 seconds 1 5 mA 250 Vdc between case and each conductor 60 seconds 0 75 mA Outputs Normally open or normally closed by model 1 x normally open 1 x normally closed Standard target size 4130 steel 3 inch ...

Reviews: