5.13 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
5.12 Max. time to wait until “0” is displayed
(frequency meter)
This parameter indicates how long it takes, when
measuring is active, until “0” is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
6. Technical data
Supply voltage
DC power supply:
10 – 30V DC/max. 40 mA
with inverse-polarity protection
Display:
6 digits, red 7 segment
LED display, height 8 mm
[0.31 in.]
Data retention:
EEPROM
Polarity of the inputs:
Programmable, npn or pnp
(sinking or sourcing) for all
inputs
Input resistance:
appr. 5 k
Ω
5.8 Multiplying factor
(frequency meter)
It can be set from 00.0001
up to 99.9999.
“0“ is not accepted!
It can be set from 00.0001
up to 99.9999.
“0“ is not accepted!
5.9 Dividing factor
(frequency meter)
The decimal point defines
the resolution in the select-
ed measuring range 1/min
or 1/sec
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
5.10 Decimal point
(frequency meter)
5.11 Display mode
(frequency meter)
Value conversion and
display in 1/s
Value conversion and
display in 1/min