1.2 Frequently used symbols

The following symbols will be frequently used in this User Manual as well as in the 
process of actual application.

Summary of Contents for E Series DX

Page 1: ...Eaton E Series DX 60 80kVA 3 phase input output User Manual...

Page 2: ...nd may not be reproduced even extracts unless permission granted Every care has been taken to ensure the accuracy of the information contained in the manual but no liability can be accepted for any er...

Page 3: ...ive items should be used for cleaning 7 In case of a fire hazard dry powder extinguishers should be used Using liquid fire extinguisher may result in electric shock hazard 8 Floor loading capacity sho...

Page 4: ...l quantity 3 As batteries are a potential electric shock and short circuit current danger to avoid accidents the following warnings should be observed during battery replacement 4 Do not expose batter...

Page 5: ...of the components and thus shorten the lifetime of the UPS 4 For long term storage the battery should be charged once every three months in normal temperature environment and once every two months in...

Page 6: ...m 8 3 4 Requirements of wiring cables and protect device for EDX series UPS 10 3 5 Parallel UPS installation 11 3 6 Procedures of connecting battery bank to UPS 12 Chapte r 4 Op eration 14 4 1 Single...

Page 7: ...equipment and can be adapted with accessories to suit industrial environments The EDX Series includes the following features Advanced DSP digital control technology to improves product performance an...

Page 8: ...2 1 2 Frequently used symbols The following symbols will be frequently used in this User Manual as well as in the process of actual application...

Page 9: ...ntain the following 1 UPS 2 Accessories including user manual Winpower Disc and two door keys 2 Check for transportation damage Should any damage be observed or parts found missing do not start the ma...

Page 10: ...KVA 80KVA models remove the steel brackets fixing the UPS to the pallet Then move the frame smoothly from the pallet to the ground If required the UPS can be fixed to the floor by re using the packagi...

Page 11: ...tructions The LCD panel is the interface used to operate the UPS It consists of three parts LED indicators LCD and function keys Please refer to the table below for the description of the LED indicato...

Page 12: ...led UPS information Function Keys selecting and opening menu items accessing information and changing system parameters etc Identifier Key Name Function Confirm Enter Select a menu or confirm an opera...

Page 13: ...ge from15 to 25 5 Altitude for normal UPS function should not exceed 1000m Should UPS be intended for application above 1000m progressive decrease of rated output should be applied as listed in the fo...

Page 14: ...r service engineers on site All operations should only be carried out by trained service personnel authorised by Eaton Only connect the AC 3 4W to the main input terminal 1 Ground wire should be conne...

Page 15: ...allation of the bypass input switch is carried out by the customer service engineers 1 Ground wire should be connected to the UPS ground terminal 2 Connect the AC input cable to the terminal block and...

Page 16: ...WG 35mm2 EDX 80KVA 80kVA 64kW 1AWG 35mm2 1AWG 35mm2 0AWG 50mm2 1AWG 35mm2 0AWG 50mm2 Machine Model AC input breaker Bypass input breaker Battery switch N wire switch AC input fuse Battery input fuse E...

Page 17: ...een UPS units should be a minimum of 10cm input wiring for each set of UPS should follow the requirements for that of single unit Each UPS input output should be connected to the same input switchboar...

Page 18: ...no voltages present on the input and output terminals and there is no voltage output of the external battery socket 2 Turn off the battery breaker 3 Remove the panel on the terminal bay and connect N...

Page 19: ...13 Remark Battery connection and replacement should be operated with the system shutdown by qualified personnel...

Page 20: ...terminal block are connected with those on the output of the battery bank 3 Switch on input breaker on the UPS and fans will start to rotate UPS will commence self diagnostics 4 Main menu can be acces...

Page 21: ...n to obtain the below information information 7 Press again to obtain the below 8 Press again to obtain the below information information 3 Press ESC to access information 4 Press to obtain the below...

Page 22: ...n warning occurs will appear at the same position as illustrated in the below picture with battery mode as an example 9 Press again to obtain the below 10 Press again to obtain the below information i...

Page 23: ...17 3 Select Yes Confirm to switch on 4 Normal Switch on the machine 5 Battery power supply switch off line input breaker 5 Switch off action press ESC to exit above picture...

Page 24: ...1 Switch off picture 2 If it is in single machine mode the following will appear 3 If it is in parallel machine mode the 4 Press ENTER following will appear 5 Select Yes Confirm to switch off the mach...

Page 25: ...n a multi module parallel system select single machine switch off if switch off is intended for the entire multi module parallel system select parallel machine switch off 6 Help 1 Help picture 2 Press...

Page 26: ...re You are able to access Setting picture by using user combination default 1234 subject to personal modification so as to set the following programs 1 Setting picture bypass power supply 2 Press 3 In...

Page 27: ...allel UPS operation EDX Series is capable of direct parallel connection customers can add additional machines on line to realise power redundancy Follow single machine operation instructions for gener...

Page 28: ...e all UPSs will transfer to INV mode Turn off when turn off is conducted under INV mode all UPSs will simultaneously turn off inverter and then transfer to the bypass mode if the UPSs are turned off o...

Page 29: ...parallel configuration 6 sets of UPS in parallel for 60KVA 80KVA models 3 EXT BATTERY TEMP PROBE temperature interface for external battery cabinet capable of battery temperature supervision so as to...

Page 30: ...tput EPO external wiring diagram 7 SERVICE Interface available only to Eaton service personnel and not open to users 8 Standard RS232 Interface applicable to WinPower management software See Appendix...

Page 31: ...25 RS485 PORT Pin Description I O 3 RXDA Input 4 RXDB Input 5 TXDB Output 6 TXDA Output RS232 PORT Pin Description I O 2 TXD Output 3 RXD Intput 5 GND Output...

Page 32: ...ing other devices connected to the power system It is recommended to connect the transformer to the input or output according to special application requirements 26 6 2 Temperature Sensor Increased ba...

Page 33: ...27 IP21 Option...

Page 34: ...to battery replacement switch off UPS and remove it from AC power B Take off metallic articles such as rings and watches C Use screw drivers equipped with insulated handles and do not place tools or...

Page 35: ...Loading level shall be less than the nominal power capacity Mains out of tolerance Check that the input wiring and input voltage are normal Battery disconnected Check the battery breaker and the batte...

Page 36: ...output should be 0 1 of nominal Overload time 10min 110 Load 125 1min 125 Load 150 Efficiency Double conversion mode Up to 94 ECO mode Up to 98 Operating Environment Ambient temperature 0 40 Storage t...

Page 37: ...ry 2 min One beep every 2 min Fault One flash every 4 sec One beep every 4 sec Overload One flash every 1 sec One beep every 1 sec 3 Line Mode Normal None Fault One flash every 4 sec One beep every 4...

Page 38: ...ry 1 sec Overload One flash every 1 sec One beep every 1 sec 6 Fault Mode Normal Long light Long beep 7 Converter Mode Normal None None Fault One flash every 4 sec One beep every 4 sec 8 ECO Mode Norm...

Page 39: ...614 03807 01...