4 Operation
4.2 Commissioning
DS7 Soft starter
09/16 MN03901001Z-EN
www.eaton.com
95
4.2 Commissioning
The factory settings for DS7-34… soft starters are configured in such a way
as to allow a suitably rated 4-pole standard motor to be run in typical soft
starter applications without the need for any additional adjustments.
In addition, soft starters belonging to the DS7-34D… series also feature a
1-0-A switch that can be used to manually switch the soft starter on and off.
The 1-0-A switch’s positions have the following functions:
•
1: DS7-SWD = ON
•
0: DS7-SWD = OFF
•
A: Control via SmartWire-DT (PNU 928.0) or via control signal terminals /
potentiometers
The 1-0-A switch can be used for starting and stopping the motor only if soft
starter DS7-34D... is supplied with 24 V DC through the SmartWire-DT ribbon
cable or the control signal terminals U
s
.
NOTICE
Make sure that there is no danger in starting the motor.
Disconnect the driven machine if there is a danger in an
incorrect operating state.
NOTICE
Before switching on the soft starter, check whether the
permissible ambient conditions have not been exceeded and
that there is no moisture inside the device. Storing the soft
starter in a cool place for example may cause moisture to occur.
If moisture has penetrated the device, ensure that it is
completely dried.
NOTICE
The electrical installation and commissioning must only be
carried out by suitably qualified personnel.
The user is responsible for ensuring suitable earthing and cable
protection for the incoming unit in accordance with local and
national regulations.
The motor must be protected from overloads!
→
For more information on the DS7-SWD’s 1-0-A switch, see
Summary of Contents for DS7 Series
Page 1: ...Manual DS7 Soft starter 09 16 MN03901001Z EN...
Page 4: ...II...
Page 36: ...1 Device series DS7 1 14 Function 32 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Page 96: ...3 Installation 3 6 Insulation test 92 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Page 188: ...8 SmartWire DT 8 9 Programming 184 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...