DS7 soft starters use phase control for controlling the voltage of the supply
network smoothly from an adjustable start value up to 100 % of the rated
value U
LN
. This voltage control enables the inrush current of a three-phase
asynchronous motor to be limited and its starting torque to be considerably
reduced. This enables a smooth and jerk-free increase in torque, adjusted to
the load behavior of the machine.
Figure 10: Function chart
a
Mains supply voltage U
LN
3 × 200 V bis 3 × 480 V
b
Antiparallel thyristors in two phases with bypass contact for controlling the motor voltage
c
Output voltage U
2
: three-phase, from an adjustable start voltage to 100% mains voltage with the use of a
ramp function at a constant line frequency
Output current I
2N
: 4 - 200 A at a maximum ambient air temperature of +40 °C
Rated motor shaft output P
2
: 1.5 - 110 kW with 400 or 3 - 150 HP with 480 V
d
Controller card for controlling the power section
This is used to initiate control commands and set the parameters.
e
SmartWire-DT interface (optional) for configuring parameters and for control and monitoring
→
The following limitations apply to single-phase AC motors:
①
U
LN
: 1 x 200 - 240 V
③
Output current I
2N
: 4 - 32 A
Rated motor shaft output P
2
with 230 V: 0.37 - 4 kW or 1/3 - 5 HP
①
②
③
④
⑤
M
3 ∼
Summary of Contents for DS7 Series
Page 1: ...Manual DS7 Soft starter 09 16 MN03901001Z EN...
Page 4: ...II...
Page 36: ...1 Device series DS7 1 14 Function 32 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Page 96: ...3 Installation 3 6 Insulation test 92 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...
Page 188: ...8 SmartWire DT 8 9 Programming 184 DS7 Soft starter 09 16 MN03901001Z EN www eaton com...