background image

DRAFT - 07 March 2016

MTL GECMA WS display modules

Modular high-resolution display panels for
MTL GECMA work stations

September 2016
INM MTL GECMA WS display rev 2

Instruction manual

MTL HMI and visualisation

Summary of Contents for Crouse-Hinds MTL GECMA WS Series

Page 1: ...FT 07 March 2016 MTL GECMA WS display modules Modular high resolution display panels for MTL GECMA work stations September 2016 INM MTL GECMA WS display rev 2 Instruction manual MTL HMI and visualisat...

Page 2: ...s electronic GmbH Heinrich Hertz Strasse 12 50170 Kerpen Germany Tel 49 2273 9812 0 Fax 49 2273 9812 100 info gecma com www gecma com Technical developments The given data is only intended as a produc...

Page 3: ...Mounting 12 6 3 Electrical installation 12 6 3 1 Electrical DC power 13 6 3 2 Video signal 13 6 3 3 Touch screen interface connection 14 6 3 4 Data connection 14 7 POWER UP 14 7 1 Brightness Regulati...

Page 4: ...WARNING Failure to comply with these instructions can endanger the lives or health of personnel and risk damage to the plant and the environment WARNING Failure to comply with these instructions can e...

Page 5: ...errors and mistakes in these operating instructions Should you have any queries or questions please do not hesitate to contact us 3 5 ATEX safety Instructions The following information is in accordan...

Page 6: ...am Read also the Special Conditions for Safe Use below for any additional or more specific information Special conditions of safe use for Zone 1 and 2 applications a The MTL GECMA WS Display Module sh...

Page 7: ...ng instructions may invalidate any warranty The MTL GECMA 19 22 and 24 WS display modules may be used in Safe Area Zone 1 and or Zone 2 applications corresponding to the Ex marking Modifications and c...

Page 8: ...times to the operating personnel Servicing maintenance work or repairs not described in this manual must not be performed without prior agreement with the manufacturer Avoid using aggressive acids or...

Page 9: ...gital video interface DVI signal from a PC in the safe area or local COMs unit dependent on which COMs version is being used A MTL GECMA WS display module MUST be powered from a MTL GECMA WS power sup...

Page 10: ...9 lower resolutions are interpolated 1920 x 1200 16 10 lower resolutions are interpolated Protection IP20 IP66 from the front Front Panel Anodised aluminium Dimensions mm WxHxD 610 x 628 x 130 710 x...

Page 11: ...potentially explosive atmospheres WARNING All earthing connections must be connected or wired prior to commissioning The connection points are labelled with the symbol shown here on the right 6 2 Mech...

Page 12: ...fully into position Fit any backing brackets supplied then begin fitting the securing screws NOTE The mounting method is different for the MTL GECMA 22 WS display panel as this unit uses additional b...

Page 13: ...iagram Colour code Pin assignment Function Yellow 22V DC Output Orange 22V DC Output Red 5V Output Black 0V Output Brown 22V DC Input Fused 3 Tighten the cable gland nut to the recommended torque to e...

Page 14: ...on manual 7 POWER UP Before switching on the system check again to make sure everything is mounted connected and installed as prescribed so as to ensure safe operation of the terminal We recommend tha...

Page 15: ...module from a fully equipped terminal requires the initial removal of the MTL GECMA WS PSU module and the MTL GECMA COM module both of which are mounted on the rear of the display module The followin...

Page 16: ...n all internal wiring has been disconnected loosen the cable gland securing nut for each of the three cables entering the PSU i e Power Display and Comms and withdraw each of the cables from the PSU h...

Page 17: ...g device such as mouse trackball RS232 connection for devices with serial interface 1 Refer to the diagram showing the connectors and disconnect the LVDS Video signal cable that goes to the display an...

Page 18: ...s of damage or mishandling as it could compromise the Ex certification of the unit IMPORTANT It is recommended that an additional person assists with the fitting of the display module to the enclosure...

Page 19: ...aining clips which will click into place when the connector is fully seated 5 Re connect the LVDS Video Signal cable into the J302 socket and re attach its earth cable to the LVDS Signal earth stud to...

Page 20: ...he middle M16 cable gland of the PSU allowing sufficient length to make the connection to the spring terminals marked Display inside the module Connector Colour code Pin assignment Function Display Ye...

Page 21: ...en all three cable gland nuts to ensure a firm grip on the incoming cables Confirm that all tools have been removed and no other loose items are left inside the enclosure before closing and locking th...

Page 22: ...eGalaxTouch_5 12 0 12204 Release131204 Newer versions of the driver are available from the manufacturer s homepage but they are not yet approved by GECMA Engineering This Driver is suitable for both...

Page 23: ...om the display can be plugged into the COMs unit before the Driver is installed NOTE The person installing the driver will require Administrator rights Check with your local IT Support before attempti...

Page 24: ...2016 INM MTL GECMA WS display rev 2 24 In the Installation Window proceed with the NEXT Button Accept terms and conditions and click Next again Uncheck the Install PS 2 interface driver option and pro...

Page 25: ...proceed with Next For the Setup Type choose the None option for the 4 point calibration NOTE The Controller is factory calibrated and the data is stored on it When the driver is installed the control...

Page 26: ...display must now be plugged into the COMs unit if not already plugged in then click OK If you require a Multi Monitor system then do not change the default setting just click the Next Button otherwis...

Page 27: ...WS display rev 2 27 Specify the Program Folder name and click Next Uncheck the Shortcut checkbox if you don t want to have a Desktop Shortcut If you want a Start Menu shortcut to the Galaxy Driver acc...

Page 28: ...e wait till it is finished Windows should now display that the new device has been recognized Normally theTouchscreen should now work as expected and you can finish here But if you think a new calibra...

Page 29: ...xTouch program If you chose the option the shortcut icon shown below will be on your desktop When the program opens it shows the connected controllers In the Tools Register you can start a new calibra...

Page 30: ...of the circles for some seconds with a pen or something similar Afterwards you should see a window for the positive calibration result Press the center of the circle for some seconds with a pen or so...

Page 31: ...heck that all the corners of the screen have been reached during the calibration process Check also that the controller is using the correct driver it should use the eGalaxTouch driver and not Windows...

Page 32: ...DRN BY 2 Iss SolidWorks A3 Eaton s Crouse Hinds Division GeCma Components electronic GmbH Heinrich Hertz Str 12 D 50170 Kerpen Telephone 49 0 2273 9812 0 Web www gecma com Title F E D C B A Scale 1 5...

Page 33: ...49 0 2273 9812 0 Web www gecma com Title F E D C B A Scale 1 5 Drg No Third Angle Projection Do Not Scale Dimensions in mm Sheet 1 of 1 10104808 1 2 3 4 5 6 7 8 3 6 4 7 2 1 5 8 E A C B F D Material Cu...

Page 34: ...49 0 2273 9812 0 Web www gecma com Title F E D C B A Scale 1 5 Drg No Third Angle Projection Do Not Scale Dimensions in mm Sheet 1 of 1 10104562 1 2 3 4 5 6 7 8 3 6 4 7 2 1 5 8 E A C B F D Material C...

Page 35: ...ve two emails A confirmation email IMPORTANT Please check your junk mailbox An email with the RMA number to be used this will be sent to you as soon as possible Please make the RMA number clearly visi...

Page 36: ...com INDIA MTL India No 36 Nehru Street Off Old Mahabalipuram Road Sholinganallur Chennai 600 119 India Tel 91 0 44 24501660 24501857 Fax 91 0 44 24501463 E mail mtlindiasales eaton com ITALY MTL Itali...

Reviews: