background image

400W

400W

C

LAM

P

respondin

g to the European Reg

.  n. 

244

/20

09

EF

FIC

IEN

CY CLASS

 

HALOGEN FLOODLIGHT

62624 (500W, 220-240V~50Hz)
62611 (500W, 220-240V~50Hz)

INSTRUCTION

Important safety information

This appliance is only suitable for outdoor use.

Electricul Safety

This floodlight must be earthed. Users are urged to follow the instructions below. Take care that the wires in 

the terminals are firmly secured and check that the power supply lid is well clamped in the cable gland. Never 

connect the yellow/green wire to terminals not marked with the earth symbol. Connect all electrical connec-

tions and wiring properly. Any faults discovered must be corrected immediately before the floodlight is used. 

Electrical connections and wiring must always be carried out by qualified staff. During use make sure that all

electrical wiring is well away from sharp tools or other objects or any other hazard, including wet floors, che-

micals, solvents, etc. Check that the floodlight is in a safe place with its support stable and on a firm surface. 

The light cannot be directed pointing downwards. If the glass in the unit breaks, replace it immediately, and 

use only original spare parts.

N.B.: Always make sure that the mains voltage is the same as the rated voltage of the floodlight. The 

floodlight’s power supply socket must be protected by a fuse.

WARNING:

The floodlight becomes very hot during operation; after switching off, wait for it to 

cool to ambient temperature. Make sure that the floodlight is placed at a safe distance 

from any inflammable material and/or surface and there is sufficient ventilation to 

ensure heat dispersal.

Assembly instructions

Fit the base into the support (G) so that the holes in the two are aligned. Tighten the fixing screw (D). To 

change the floodlight’s direction, simply undo the fixing screw (D) and tilt the floodlight into the position 

required. Then retighten the screw (D).

Fitting the lamp

Disconnect the power supply before fitting or replacing the halogen lamp. To fit the lamp supplied, undo the 

screw (B) and open the front cover. The lamp is fitted by means of sprung fixtures at each end. Fit the lamp 

into the support carefully, ensuring that contact is made at both ends. Take care not to touch the lamp with 

bare hands; if this occurs, clean the lamp with alcohol. Close the front cover and retighten the retainer screw 

(B). DO NOT OVER-TIGHTEN AS THIS MAY DAMAGE THE GLASS.

Specification

220V-240V~50Hz

Rated power: max. 500W

Degree of protection: IP 54

Halogen lamp: junction R7s length 118 mm cod. 62603

Power supply lead: H07RN-F 3Gx1,0 length 3m

Tempered glass: 178x140x5mm4 cod. 62604

MADE IN CHINA

IMT1004

Parts Identification

A

 Handle

B

  Glass retainer screw

C

  Safety grille

D

 Fixing screw

E

 Base

D

 Power supply cable

G

 Support

Wiring System

A

C

B

F

G

D

E

Reviews: