Eaton 5S 850 Installation And User Manual Download Page 9

9

614-06819-00

(For further information, visit the www.powerquality.eaton.com site or contact after-sales support.)

  Problem

Diagnostic

Solution

1

• 

The battery backup outlets 

19

 

are not supplied with power.

• 

Button

 

6

 

is not lighted on.

• 

Press button

 

6

 

and check that 

it turns green.

2

• 

The connected devices are not 

supplied when AC power fails.

• 

The devices are not connected 

to the battery backup outlets 

19

.

• 

Connect the devices to the 

battery backup outlets 

19

.

3

• 

AC power is available, but the 

UPS operates on battery power.

• 

Circuit breaker 

20

, located 

under the UPS, has been tripped 

by an overload on the UPS 

output.

• 

Disconnect excess equipment 

and reset the circuit breaker 

20

 

by pressing the corresponding 

button.

4

• 

Green button

 

6

 

flashes and 

audio alarm beeps every 3 

seconds.

• 

The UPS battery backup outlets 

19

 are overloaded.

• 

Disconnect excess equipment 

connected to the battery backup 

outlets 

19

 .

5

• 

Fault sign 

12

 appear on the 

LCD panel and audio alarm beep 

continuously.

• 

A fault has occurred on the UPS. 

The battery backup outlets 

19

 are 

no longer supplied.

• 

Call after-sales support.

6

• 

EcoControl outlets keep powered 

when main application (Master 

outlet) is stopped.

• 

EcoControl function is not 

activated or not properly set.

• 

Activate or set properly 

EcoControl function using the 

software provided with the 

product.

8. Troubleshooting

AC-power disturbance 

• 

 If AC power is disturbed or fails, the UPS continues to operate on battery power.  

Button 

6

 flashes green. In normal mode, the audio alarm beeps every ten seconds, 

then every three seconds when the end of battery backup time is near. In silent mode 

(see the section on settings), the audio alarm simply beeps once when the UPS 

transfers to battery power.

• 

 If the power outage lasts longer than the battery backup time, the UPS shuts down 

and automatically restarts when power is restored. Following a complete discharge, a 

few hours are required to recharge the battery back to full backup time.

• 

 To save battery power, it is possible to press button 

6

 to cut the supply of power to 

the devices connected to the battery backup outlets.

Lightning protection: 

All outlets, whether backed up or simply filtered, include surge protection, whatever the 

position of button 

6

.

Shutdown of the battery backup outlets 19 

Press button 

6

 for more than two seconds.

Summary of Contents for 5S 850

Page 1: ...Installation and user manual EATON 5S 850 1200 1600 ...

Page 2: ... 614 06819 00 2 3 1 5 EATON 5S Packaging l Before installing the Eaton 5S read the booklet 3 containing the safety instructions to be respected Then follow the instructions given in this manual 2 Caution ...

Page 3: ...3 614 06819 00 Quick start B C A 1200 1600 850 D ...

Page 4: ...e life is reduced by 50 for every ten degrees above 25 C The battery elements must be replaced exclusively by qualified personnel risk of electrocution with new elements approved by Eaton to ensure correct operation of the UPS The battery must be disposed of in accordance with applicable regulations To remove the battery elements shut down the UPS button 6 OFF remove the power cord and proceed as ...

Page 5: ...max 7 3 A max Leakage current 0 4 mA Input protection 10 A resettable circuit breaker Transfer time 5 ms typical Telephone surge protection Tel ISDN ADSL Ethernet Sealed lead acid battery 12 V 9 Ah 2 x 12 V 7 Ah 2 x 12 V 9 Ah Automatic battery test Once a week Average battery life 4 years typical depending on temperature and amount of discharge cycles Operating temperature 0 to 35 C Storage temper...

Page 6: ...UPS can be installed in horizontal vertical position or placed in Rack 2U optional kit 2 Description AVR Min Hz kVA kW 6 7 8 6 ON OFF button for the battery backup outlets 7 Scroll down 8 Mute alarm LCD 16 15 14 17 11 10 9 12 13 9 UPS ON 10 AVR mode 11 Battery mode 12 Internal fault 13 Output load level 14 Battery level 15 Input measurements 16 Output measurements 17 Measuring unit Outlets 20 19 1...

Page 7: ...Register for the warranty on powerquality eaton com 4 Master and EcoControl outlets operating procedure In order to limit energy consumption of peripherals scanner printer in standby mode the Eaton 5S is equipped with EcoControl outlets that are dependent on the Master outlet When the main application supplied by the Master outlet computer is shut down the EcoControl outlets are automatically deac...

Page 8: ...Filtered outlets 18 without battery backup Equipment connected to these outlets is supplied as soon as the AC cord 4 is plugged in They are not affected by button 6 Battery backup outlets 19 Equipment connected to these outlets is supplied as soon as button 6 turns green see figure D These outlets can be turned on even if the UPS is not connected to AC power button 6 flashes 6 UPS setting through ...

Page 9: ...er supplied Call after sales support 6 EcoControl outlets keep powered when main application Master outlet is stopped EcoControl function is not activated or not properly set Activate or set properly EcoControl function using the software provided with the product 8 Troubleshooting AC power disturbance If AC power is disturbed or fails the UPS continues to operate on battery power Button 6 flashes...

Page 10: ......

Reviews: