background image

1

General instructions for Multiplate couplinG

   E-MEQD-II003-E   December 2020   www.eaton.com

1.0 INTRODUCTION

This document illustrates operating instructions for Eaton’s Multi-FF series Multiplate quick disconnect coupling. This user 

manual also provides guidance about preventive maintenance of Multiplate coupling and steps for servicing in case of 

malfunction.

2.0 

SAFETY INSTRUCTIONS

 

It is recommended to wear hand-gloves while making connection or disconnection of Eaton’s Multi-FF device.

 

Hold top plate / movable plate on hose lines or on to a surface perpendicular to handle strips, to avoid finger 

entrapment during engagement with fixed plate.

 

Once two plates / sub-systems are engaged, remove your hand off the plate and only rotate the handle. Do not put 

hand/fingers in between 2 plates.

 

Ensure that fingers are not entrapped in between bottom/fixed plate and handle of the device during operation

 

Ensure absence of pressure inside the Multi-FF before initiating disconnection of system or carrying out any 

maintenance work.

3.0 

OPERATING CONDITIONS 

This section covers general operating conditions to obtain long life of multiplate coupling without unpredicted failure.  

It is advisable to use multi plate coupling under same operation conditions.
The allowed operating temperature lies between -20°C to 100°C. This is operating temperature of multiplate coupling 

assembly and subjected to change based on seal material configuration of Coupling half. The permitted storage 

temperature lies b10°C and +35°C.
The maximum operating relative air humidity should not exceed 75%. Similarly, it should not exceed 60% for storage.
Dust & vibration free environment will ensure correct functionality of multiplate coupling.
Maximum operating pressure for multiplate coupling is as follow. These are tested at 1:4 times operating pressure and it 

is advisable that system pressure for continuous service shall not exceed maximum operating pressure recommended 

below.

Multiff part 

number

no. of 

coupling 

ports

coupling 

body size

Max. operating 

pressure

4MFC-10CUP15LS11

4

ISO 10

250 bar

4MFCE1-12CUP15L

4

ISO 12

350 bar

4MFC-12CUP15L

4

ISO 12

350 bar

4MFC-1015L

4

ISO 10

350 bar

4MFCE1-1015L

4

ISO 10

350 bar

6MFC-1015L

6

ISO 10

350 bar

User Manual

Summary of Contents for 4MFC-1015L

Page 1: ...General instructions for Multiplate coupling User Manual ...

Page 2: ...ii General instructions for Multiplate coupling E MEQD II003 E December 2020 www eaton com ...

Page 3: ...anual Contents 1 0 INTRODUCTION 1 2 0 SAFETY INSTRUCTIONS 1 3 0 OPERATING CONDITIONS 1 4 0 DURABILITY AND LIFETIME 2 5 0 MAINTENANCE 2 6 0 PRODUCT DESCRIPTION 3 7 0 INSTALLATION 4 8 0 SERVICING 4 8 1 SOCKET HALF REPLACEMENT 4 8 2 PLUG HALF REPLACEMENT 5 8 3 REPLACEMENT PART NUMBERS 6 9 0 OPERATING 6 ...

Page 4: ...enance work 3 0 OPERATING CONDITIONS This section covers general operating conditions to obtain long life of multiplate coupling without unpredicted failure It is advisable to use multi plate coupling under same operation conditions The allowed operating temperature lies between 20 C to 100 C This is operating temperature of multiplate coupling assembly and subjected to change based on seal materi...

Page 5: ...NANCE Components must be maintained after every 12 months storage period for the purpose of monitoring and repairs Replacement with original parts will ensure correct functionality Clean your quick coupling system once a week or every 50 coupling decoupling cycles To do this use the usual cleaning agents such as dry ice After doing so lubrication must be carried out Apply solid lubricant grease af...

Page 6: ...n of 2 or more QDC s in a single operation Briefly this system would have two pre assembled sub systems one comprising of male halves plugs and other one having equal number of female socket halves with centralized locking mechanism These two sub systems when guided together with the help of handle operated mechanism will connect all QDC s together and open the internal flow path Figure 2 Multipla...

Page 7: ...d details 8 0 SERVICING Key components of Eaton s Multi FF can be easily serviced and replaced upon malfunction Following sections and figures illustrates step by step guide for replacing these components with use of standard tools 8 1 SOCKET HALF REPLACEMENT Figure 3 Socket female half assembly on fixed plate Socket female half assembly on fixed plate comprises of 2 sub components 1 Socket Female...

Page 8: ...ction of coupling and rotate in clockwise direction to apply torque as per below chart Coupling series Coupling size Coupling half Torque in N m FF ISO 16028 ISO 6 Socket 60 FF ISO 16028 ISO 10 Socket 60 FF ISO 16028 ISO 12 Socket 90 FF ISO 16028 ISO 16 Socket 90 FF ISO 16028 ISO 19 Socket 100 FF ISO 16028 All Plug 30 8 2 PLUG HALF REPLACEMENT Figure 4 Plug male half assembly on movable plate Plug...

Page 9: ...correct parts for replacement Other end connections are also available upon request for plug and socket coupling assemblies MultiFF Part number Plug coupling Socket coupling Dust cap seal 4MFC 10CUP15LS11 10FFPCUP12LS21 10FFS15LS21 4MFS21 10S11 4MFCE1 12CUP15L 12FFPCUP15LS21 12FFS15LS21 4MFS21 12 4MFC 12CUP15L 12FFPCUP15LS21 12FFS15LS21 4MFS21 12 4MFC 1015L 10FFP15LS21 10FFS15LS21 4MFS21 10 4MFCE1...

Page 10: ...e that system pressure is bled off to tank by switching to correct direction control valve position and attachment on equipment is grounded properly Disconnection of Multi FF coupling under pressure is not recommended 2 After ensuring step 1 points push the Red push button mounted on side face of fixed plate 3 With red button still pushed inside rotate the handle in clockwise direction through 130...

Page 11: ...8 General instructions for Multiplate coupling E MEQD II003 E December 2020 www eaton com User Manual Notes ...

Page 12: ...Eaton EMEA Headquarters Route de la Longeraie 7 1110 Morges Switzerland Eaton eu 2020 Eaton All Rights Reserved Publication No E MEQD II003 E December 2020 ...

Reviews: