Instruction  Leaflet  

IL29C203J

Effective October 2011

Installation Instructions for Motor Operator for

 

L-Frame and MDL-Frame Circuit Breakers and

 

Molded Case Switches

The instructions  for installation, testing , maintenance,  or repair 

herein are provided for the use  of the product in general commercial  

applications  and may not be appropriate for use  in nuclear  applica-

tions.  Additional instructions  may be available upon specific  request  

to replace,  amend,  or supplement  these  instructions  to qualify them 

for use  with the product in saf ety-related  applications  in a nuclear  

facility.
This Instr uction Booklet is published solely  for information purposes  

and should not be considered  all-inclusive.  If further information is 

required,  you should consult  an authorized Eaton  sales  represent a-

tive.
The sale  of the product shown in this literature is subject  to the 

terms  and conditions  outlined in appropriate Eaton  selling policies  

or other contractual agreement  between  the parties . This literature 

is not intended to and does  not enlarge or add to any such contract . 

The sole  source  governing the rights and remedies  of any purchaser  

of this equipment  is the contract  between  the purchaser  and Eaton .

NO  WARRANTIES,  EXPRESSED  OR  IMPLIED , INCLUDING  

WARRANTIES  OF  FITNESS  FOR  A PARTICULAR  PURPOSE  OR  

MER CHANTABILITY,  OR  WARRANTIES  ARISING  FR OM  COUR SE  

OF  DEALING  OR  USA GE  OF  TRADE,  ARE  MADE  REGARDING  

THE  INFORMA TION,  RECOMMEND ATIONS,  AND  DESCRIPTIONS

 

CONT AINED  HEREIN.

 

In no event will Eaton  be responsible  to the purchaser  or user  in 

contract,  in tort (including negligence),  strict  liability or other wise  

for any special,  indirect,  incidental or consequential  damage  or loss  

whatsoe ver,  including but not limited to damage  or loss  of use  of 

equipment,  plant or power  system,  cost  of capital, loss  of power,  

additional expenses  in the use  of existing power  facilities,  or claims  

against  the purchaser  or user  by its customers  resulting  from the 

use  of the information,  recommendations  and description  contained 

herein.

Summary of Contents for 1483D43G17

Page 1: ...et IL29C203J Installation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches Contents Description Page 1 0 Introduction 2 2 0 Installation 2 3 0 Operation 6 4 0 Adjustment 9 Effective October 2011 ...

Page 2: ...he circuit break er to be opened closed or reset remotely It has the is removed The motor operator mechanism is driven by a reversible electric motor connected to a ball screw The ball screw drives the circuit breaker handle Limit switches are used to control the motor 2 0 INSTALLATION The motor operator is UL listed and suitable for field Figure 1 1 Motor Operator Installed on L Frame Series C Ci...

Page 3: ...ied for this purpose The nameplate should be placed on the top side of the motor operator The installation procedure consists of inspecting the motor operator for completeness and mounting the motor operator to the circuit breaker and connecting the control wires To install the electrical operator perform the following steps 2 1 Remove motor operator from packing Inspect it for completeness Figure...

Page 4: ...he handle extension must be located between the rollers of the operator bracket assembly and the motor end of the operator is positioned towards the line end of the breaker Figure 4 1 2 6 The motor operator is equipped with two PUSH TO TRIP actuators for use on either solid state left hand actuated or thermal magnetic right hand actuated trip units Mount the red PUSH TO TRIP BUTTON MOLDING TO THE ...

Page 5: ...22 in lb 20 22 in lb 17 19 in lb 9 10 ft lb Hex shaped studs for standard mounting Use round shaped studs for use with PAD3LD Plug In Adaptors NOTE If barriers become seperated from cover orient barriers with Chamber toward Load End of Breaker Figure 2 2a Figure 2 2b 20 22 in lb 20 22 in lb 17 19 in lb NOTE If barriers become seperated from cover orient barriers with Chamber toward Load End of Bre...

Page 6: ...E MOTOR OPERATOR SWITCHING OPERA TIONS COULD CAUSE DAMAGE TO EQUIPMENT ESPECIALLY EQUIPMENT REQUIRING A CON TROLLED SHUTDOWN CAUTION DO NOT EXCEED THE DUTY CYCLE OF OFF TO ON TO OFF AT ONE PER MINUTE EXCEEDING THE MAXIMUM OPERATING RATE CAN DAMAGE THE MOTOR OPERATOR DO NOT CONNECT THE MOTOR OPERATOR TO VOLTAGES ABOVE THE RATED VOLTAGE OF THE DEVICE VOLTAGES THAT EXCEED THE RATED VOLTAGE CAN CAUSE ...

Page 7: ...7 Instruction Leaflet IL29C203J Installation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches EATON CORPORATION www eaton com ...

Page 8: ...stallation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches EATON CORPORATION www eaton com Figure 3 2 Motor Operator in Electrical Position Figure 3 3 Motor Operator in Manual Position ...

Page 9: ...e carriage travel After adjusting tighten the screws 4 5 For lower limit switch adjustment loosen the two pan head screws securing the lower limit switch assem bly Move the switch down to increase the carriage travel Move the switch up to decrease the carriage travel After adjusting tighten the screws NOTICE CAUTION Figure 4 1 Motor Operator Limit Switch Locations LINE Upper Limit Switch Limit Swi...

Page 10: ...0 50 60 50 60 50 60 DC DC Motor in Rush Operator is an intermittent duty device The safe duty cycle OFF to ON to OFF should not exceed one per minute Electrical Operating times at rated voltage a To turn breaker ON 0 2 second 12 cycles max b To turn breaker OFF 0 2 second 12 cycles max Motor Operating temperature Class A temperature limits apply Applied Voltage should be no less than 85 or no more...

Page 11: ...ame Circuit Breakers and Molded Case Switches EATON C ORPORATION www eaton com 10 750 5 375 8 246 4 136 12 120 9 620 870 1 750 250 2 870 120 3 440 6 000 6 050 1 800 1 280 1 370 2 750 4 810 9 530 24 2 RESET R 7 496 3 953 WITHADAPTERPLATE 3 700 WITHOUTADAPTERPLATE 1 982 14 7 ON HANDLE HANDLE Figure 4 2 ...

Page 12: ...er 2011 Installation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches EATON CORPORATION www eaton com 14 7 ON 24 2 RESET 2 024 5 616 8 302 4 125 8 250 16 000 R 7 496 10 750 HANDLE HANDLE Figure 4 2b ...

Page 13: ... Instruction Leaflet IL29C203J Effective October 2011 Installation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches CORPORATION www eaton com Notes EATON ...

Page 14: ...14 Instruction Leaflet IL29C203J Installation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches EATON CORPORATION www eaton com Notes ...

Page 15: ... Instruction Leaflet IL29C203J Effective October 2011 Installation Instructions for Motor Operator for L Frame and MDL Frame Circuit Breakers and Molded Case Switches EATON CORPORATION www eaton com Notes ...

Page 16: ...ation is required you should consult an authorized Eaton sales represent a tive The sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between the parties This literature is not intended to and does not enlarge or add to any such contract The sole source governing the rights and remedies ...