Configuration guide
Eaton 1250W / 1500W / 1800W Inverter Operation and Installation Guide
IM SP180164 / Rev D www.eaton.com
•
Enable/Disable the inverter output
•
Enable/Disable the audible alarm
•
Modifying the shutdown voltage value
•
Select battery type for charging
•
Set to factory defaults (see Figure 2: Setting flow chart)
Configuration guide
This chapter describes inverter operation, configuration and the meaining of error codes.
Setting battery types on main unit (models with battery charger only)
The inverter can operate from and recharge several different types of lead-acid batteries. It is important to make sure the bat-
tery type is configured on the unit for optimum charging process before installing batteries. See Table 1.
Customizing display, alarm and charging current settings
The display panel is capable of adjusting the following:
•
What is presently displayed on the screen
•
Modify the charging current
Table 1.
Charge voltage VDC (tol/-
0.2Vdc)
Battery type setting Bulk
Absoption
Float
Fixed 13.5
13.5
13.5
13.5
Flooded
14.4
14.4
13.5
Gel
14.2
14.2
13.8
AGM
14.3
14.3
13.4
WARNING
Fire hazard –
Programming the incorrect battery type may
result in battery damage and a fire risk.
To change display and read current inverter settings:
By default, the screen will display the input voltage in [Volts] and the “
Input Voltage (V)
” LED indicator will be illuminated.
1. Press the
SELECT
button once. Screen displays the DC input current in [Amperes] and the “
Input Current (A)
” LED
indicator will illuminate.
2. Press the
SELECT
button once more. Screen displays the AC output power in [kilowatts] and the “
Output power (KW)
”
LED indicator will illuminate.
3. Press the
SELECT
button once more. Screen displays the Low Voltage Shut Down Level: 11.8, 12.2, 10.5.
4. Press the
SELECT
button once more. Screen displays the alarm setting: AL1 = Alarm on; AL0 = Alarm off.
5. Press the
SELECT
button once more. Screen displays the battery charge current setting.
6. Press the
SELECT
button once more. Screen displays the battery type for charging: Fl = Fixed; FLo = Flooded; gEL =
Gel, Ag = AGM.
ote:
N
If model equipped with AC bypass switch, selections will vary while in bypass mode.
Figure 1. Inverter display panel
Power button located on the left side. SELECT button located on the right.
Fault