background image

Instructional Leaflet

 

P26841

Effective July 2014

10250T/E34 Pushbuttons

And Indicating Lights

Eaton

1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

© 1999 Eaton
All Rights Reserved

Publication No. P26841 / 004
August 2014

Eaton is a registered trademark.

All other trademarks are property 

of their respective owners.

n

e

p

O

 t

c

a

t

n

o

C

 

=

 

O

d

e

s

o

l

C

 t

c

a

t

n

o

C

 

=

 

X

t

n

e

m

e

g

n

a

r

r

A

 t

i

u

c

ri

C

 

d

n

a

 

n

o

it

i

s

o

P

 r

o

t

a

r

e

p

O

k

c

o

l

B

 t

c

a

t

n

o

C

r

e

b

m

u

N

 

g

o

l

a

t

a

C

r

o

t

a

r

e

p

O

 f

o

 

e

p

y

T

Out — Pull

Intermediate

In — Push

Contact Block Mounting Location

1

2

1

2

1

2

2-Position Operator without Lens

X

X

O

O

O

N

I

Maintained Push-Pull

10250T5/E34GDB

O

O

X

X

C

N

I

X

X

O

O

O

N

2

O

O

X

X

C

N

2

3-Position Operator without Lens

Momentary Push-Pull

10250T4/E34GEB

1NO

O

O

O

O

X

O

1NC

X

X

O

X

O

O

Maintained Push-

10250T9/E34GFB

2NO

O

O

O

O

X

O

O

O

X

O

X

X

C

N

2

ll

u

P

 

y

r

a

t

n

e

m

o

M

1NO

O

O

O

O

X

X

Momentary Push-Pull

10250T10/E34GHB

1NC

X

X

O

O

O

O

2NO

O

O

O

O

X

X

2NC

X

X

O

O

O

O

or

No Intermediate

Position

or

or

or

or

or

or

or

Push-Pull Operators — Contact Block Selection 
And Assembly

The illustration to the right assists in the selection of 

contact blocks. Symbols 1 and 2 show locations of 

contact circuits after assembly of contact blocks and 

adapter to the operator. The chart below shows the 

effects of the push and pull operations on either NO 

or NC contacts.

Grounding Of 10250T And E34 Components General

With any electrical component there is the possibility of a 

loose wire, moisture, etc. causing a short circuit between 

the component and ground. If the device is adequately 

grounded, the condition causes the protective fuse or circuit 

breaker to open and remove the potential. If not, an electri-
cal hazard may remain unnoticed.

Grounding Nibs — 10250T

The 10250T operator is designed to make direct metallic 

contact to the rear of the panel (with no intervening spacer 

washers to interfere with component-to-panel ground con-

tinuity). As a further aid in establishing an electrical ground, 

the operator has four metal points (“grounding nibs”) 

designed to penetrate most paints or other protective coat-

ings.

Penetration of these nibs is dependent upon the torque 

applied to the mounting nut. Recommended torque is 5 ft-

lbs (6.8 Nm). More or less may be necessary to penetrate 

the specific type and thickness of your panel coating. Test 

for continuity to ground after installation. If a short circuit 

to ground does occur, the fault should be corrected and the 

device replaced.

Earth Ground Terminals — E34

These devices are supplied with an integral earth/ground 

terminal. A 6-32 terminal screw will accommodate ring type 

terminations for bonding to international specifications.

Locating Nib

1

2

Earth

Terminal

Nibs

Reviews: