PM CHASSIS UNIT MANUAL 

 

 

:E\Manuals\Others\Qualitair\QPM\LG3298L/22QPMChassisUnit  

 

 

PERFORMANCE DATA 
 
Total Cooling Capacity   

3.1kW 

Sensible Cooling Capacity 

2.1kW 

 
Based on:  

 

Internal Conditions of 21°Cdb – 15°Cwb 
External Conditions of  27°Cdb – 19°Cwb 
 
PHYSICAL DATA 
 
Height 

   360 

Width 

   875 

Depth 

   475 

Weight                        

52kg 

 
ADDITIONAL DATA 
 
Refrigerant 

  R22 

Charge 

Weight 

  1.56kg 

Shipping Weight 
(2 units on pallet) 

 

124kg 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
MAIN COMPONENT PART N

os

 

Description Part 

N° 

 
10A Fuse 
3.15 Fuse 
Compressor Start Relay 
Delay Start Timer 
Pressure Switch (L/P) 
L/P Switch Timer 
Compressor 
Condensate Hose 
Selector Switch (Rotary) 
Condenser fan motor capacitor 
Fan  
Low Ambient/De-Frost Thermostat 
Evaporator fan Deck Assembly 
Condenser Fan Impellor 
3-pole C/O Relay 
2-Pole C/P Relay 
Rocker Switch 
Filter Pad (Fresh Air 
Control Thermostat 

 
LG3298L/13 
1080379 
1170171 
J211300023 
2100162 
1230050 
2050104 
2560028 
J9990397 
J9991420 
J9991486 
LG2995/02 
LG3298L/01 
LG3298L/02 
LG3298L/08 
LG3298L/09 
LG3298L/11 
LG3298L/12 
LG3298L/07 

 

Summary of Contents for Qualitair

Page 1: ...3298L 22QPMChassisUnit E Ea at to on n W Wi il ll li ia am ms s L Lt td d TECHNICAL MANUAL INSTALLATION PROCEDURES FOR QPM CHASSIS UNIT Eaton Williams Ltd Station Road Edenbridge Kent TN8 6EG Tel 44 0...

Page 2: ...d Electrical Hazards are kept to a minimum c The equipment has been fitted with doors and covers to prevent access during operation These must be kept in place and additional guards fitted if necessar...

Page 3: ...es to have been installed to the manufacturer s original requirements be in good working order and be to the minimum standard as seen and witnessed at site approval meeting held on 98 Colin Symmonds W...

Page 4: ...and the upper control to the desired setting For Fresh Air Operation The fresh air damper can be opened or closed using the selector switch as desired INTERNAL PROTECTION DETAILS Low Refrigerant Press...

Page 5: ...PM CHASSIS UNIT MANUAL E Manuals Others Qualitair QPM LG3298L 22QPMChassisUnit...

Page 6: ...the evaporator fan assembly onto a rigid surface to allow inspection of the air on face of the coil Cleaning can be carried out by gently vacuuming both faces Condensate Drain Check condensate drain f...

Page 7: ...24kg MAIN COMPONENT PART Nos Description Part N 10A Fuse 3 15 Fuse Compressor Start Relay Delay Start Timer Pressure Switch L P L P Switch Timer Compressor Condensate Hose Selector Switch Rotary Conde...

Page 8: ...PM CHASSIS UNIT MANUAL E Manuals Others Qualitair QPM LG3298L 22QPMChassisUnit...

Page 9: ...PM CHASSIS UNIT MANUAL E Manuals Others Qualitair QPM LG3298L 22QPMChassisUnit...

Page 10: ...PM CHASSIS UNIT MANUAL E Manuals Others Qualitair QPM LG3298L 22QPMChassisUnit PM CHASSIS UNIT MANUAL E Manuals Others Qualitair QPM LG3298L 22QPMChassisUnit...

Reviews: