![Easywave RCJ05 User Manual Download Page 2](http://html.mh-extra.com/html/easywave/rcj05/rcj05_user-manual_524185002.webp)
If the control unit receives a rain signal from the
weather sensor, the awning will be retracted.
Once the rain alarm is over, a lock-out period of
approximately 8 to 20 minutes must expire before
the awning can be extended again manually bzw.
ist die Sonnenfunk-tion wieder nutzbar.
Depending upon the size of the awning, different
motor running times are required for fully
retracting and extending the awning. This time
can be measured and saved in the control unit.
1. Hold button P pressed until the WIND/RAIN
and OPEN/STOP/CLOSE buttons start to
flash alternately. Button P lights up.
2. Hold the OPEN or CLOSE direction buttons
pressed for the entire time that the awning is
extended or retracted.
3. Release the button. The running time is
saved.
If wind or rain thresholds have been
exceeded, it is not possible to measure
the running time for the extension of the
awning.
A1
Installing/connecting the control
A
Putting the receiver into service
B
Operating the awning control
B
Operating the awning control
A3
Programming the transmitter
C2
Deleting remote controls
multi-pin connector
1. Turn the mains supply voltage off. Connect
the cables for the power supply and the
awning motor to the control unit as shown in
the connection diagram. The PE (protective
earth) connection of the mains cable must be
connected externally to the PE connection of
the drive. Use terminals S+ and S- if you wish
to connect a wired weather sensor.
2. Plug in the 5-pole pin connector supplied to
the connection socket on the rear of the
receiver.
3. SInsert the control unit into the junction box
and screw this firmly to the mounting frame.
Plug in the receiver with the 5-pole pin
connector straight into the connection socket
on the control unit and ensure that the
receiver engages securely in the mounting
frame.
Switch the supply voltage on. All buttons light up
briefly one after the other. The awning can now
be operated using the OPEN, STOP and
CLOSE buttons.
The WIND/RAIN and SUN buttons flash as the
weather sensors have not yet been programmed
in.
Now transfer the programming codes of the
weather sensor to the control unit.
1. Hold button P pressed until the WIND/RAIN
and OPEN/STOP/CLOSE buttons start to
flash alternately. Button P lights up.
2. Press the STOP button briefly. The button
flashes rapidly and button P lights up.
3. Then, within 60 seconds, press and release
the button(s) of your Easywave transmitter.
The transmission code is then transferred.
After approx. 4 seconds, the STOP button
goes out and the awning can be operated via
the remote control or the status of the
weather function can be requested.
Up to 32 transmission codes can be pro-
grammed.
1. Hold button P pressed until the OPEN/
STOP/CLOSE and WIND/RAIN buttons start
to flash alternately. Button P lights up.
2. Press button P again and hold. The OPEN/
STOP/CLOSE and WIND/RAIN buttons
flash rapidly. Button P lights up.
3. Press the STOP button briefly. The button
flashes rapidly and button P lights up.
4. Then, within 10 seconds, press and release
the button of your transmitter. The STOP
button goes out after 4 seconds. The sensor
transmission code has been deleted.
If you wish to delete all transmitters, proceed as
described in steps 1 to 3, and in step 4 press and
hold the STOP button again.
1. Hold button P pressed until the OPEN/
STOP/CLOSE and WIND/RAIN buttons start
to flash alternately. Button P lights up.
2. Press button P again and hold. The OPEN/
STOP/CLOSE and WIND/RAIN buttons
flash rapidly. Button P lights up.
3. Press the WIND/RAIN button briefly. The
button flashes rapidly and button P lights up.
4. Press the WIND/RAIN button and hold.
Button P is off and the WIND/RAIN button
goes out after 4 seconds. The sensor
transmission code has been deleted.
N
230 V
L
M
-
S
-
S
+
S
+
S
230 V ~ 50Hz
M
N
N
L
L 4A
IP40
>5 s
>5 s
>5 s
<2 s
<2 s
<2 s
4 s
4 s
A2 Programming the weather sensor
C1
Deleting weather sensor
C
Delete function
1. Hold button P pressed until the WIND/RAIN
and OPEN/STOP/CLOSE buttons start to
flash alternately. Button P lights up.
2. Press the WIND/RAIN button briefly. The
button flashes rapidly and button P lights up.
3. Then, within 60 seconds, press and release
the “prog” transmitter button of your sensor.
The transmission code is transferred. The
WIND/RAIN button will go out after four
seconds and the SUN button will light up.
The sensor has now been programmed in
and all the weather functions are available
for use.
>5 s
<2 s
4 s
B5
Manual operation of the awning
To control the awning, briefly press one of the
OPEN/STOP or CLOSE direction buttons on the
receiver. The awning moves in the desired
direction or can be stopped.
The awning control unit can be operated using
aRT37 status transmitter or using other
Easywave transmitters with three-button
controls. If the awning is operated with a remote
control, the relevant direction button on the
control unit flashes.
< 3 s
B1
Wind function
B2
Rain function
B6
Emergency operation
The wind function is active once a weather sensor
has been programmed. This function takes
priority over all other weather functions and
cannot be disabled.
If the wind speed exceeds the threshold value
programmed in the sensor, the awning will be
retracted. The WIND/RAIN button lights up red
until the wind cycle has been completed
If the wind speed falls below the threshold value,
a lock-out periode of approximately 8 to 20
minutes must expire before the awning can be
extended again manually or the controls can
respond to rain or sun signals.
.
The rain function can be used as soon as a
weather sensor with a rain detection feature has
been programmed in, provided that the
“gastronomy” function has not been switched on
at the weather sensor.
By pressing the WIND/RAIN button, the rain
function can be switched off and the button
flashes blue
If a rain signal is received from the weather
sensor, the awning is retracted and the
WIND/RAIN button lights up blue until the rain
cycle has been completed.
.
B3
Sunlight function
The sunlight function is active if a weather sensor
with a brightness sensor has been programmed
into the control uni. The sunlight function can be
switched on or off using the SUN button.
If the level of brightness exceeds the set
threshold value for a period of 12 to 15 minutes,
the awning will be extended. If a wind or rain
threshold has been exceeded, it will not be
possible to extend the awning until the lock-out
period has expired.
If the level of brightness drops below the set
threshold value for a period of 30 to 33 minutes,
the awning will be retracted.
These times for delaying the extension and
retraction operations are necessary in order to
prevent the awning from being constantly
extended and retracted in rapidly changing light
conditions.
8-20 min
12 to 15 min
30 to 33 min
A4 Saving motor running time value
>5 s
>5 s
>5 s
mounting frame
radio receiver
control
4 s
C3 Deleting the motor running time
1. Hold button P pressed until the OPEN/
STOP/CLOSE and WIND/RAIN buttons start
to flash alternately. Button P lights up.
2. Press button P again and hold. The OPEN/
STOP/CLOSE and WIND/RAIN buttons
flash rapidly. Button P lights up.
3. Press the OPEN or CLOSE button and hold.
The buttons flash rapidly and button P lights
up. Release the button. All buttons go out
and the running time has been deleted.
>5 s
>5 s
In order to carry out maintenance and repair work,
an emergency manual operating mode on the
control unit can be used for operating the awning.
The wind function is no longer active when
the manual mode is used. Do not extend
the awning in strong winds. You could
injure yourself and permanently damage
the awning.
2
3
The gastronomy function can only be used in
ombination with a weather sensor that has a rain
detection feature and an activated gastronomy
function.
If a rain signal is received from the weather
sensor, the awning is extended automatically if it
rains and the button lights up blue. If no rain
further rain signals are transmitted and the level
of brightness remains below the threshold level
for 30 to 33 minutes, the awning is automatically
retracted.
The gastronomy function can be disabled by
pressing the WIND/RAIN button or SUN button,
the WIND/RAIN button
lights up blue, the SUN
button goes off. Note that if the gastronomy
function is interrupted, then the sunlight function
is no longer available.
Only awnings that are specially designed
for use in rain may be operated using the
gastronomy function.
B4
Gastronomy function
Gastronomy function
ON
>5 s
8-20 min