background image

Supine

16. With one hand supporting the unit, Adjust to the 

desired supine position by depressing the lever on 

the rear handle and tilting. This can be done with 

the user in the unit.

Rear 

Handle

Prone

17. With one hand supporting the unit, Adjust to the 

desired prone position by depressing the lever on 

the rear handle and tilting. This can be done with 

the user in the unit.

Page 17

Page 2

•  Please read and understand all safety precautions and user instructions prior to use. Call Altimate Medical at 800-342-8968 or 

 

507-697-6393 with any questions or for additional information.

•   If a user does not meet the specifications below and has not been properly fitted by a qualified therapist or physician, 

 

Altimate Medical, Inc., does not recommend using the Zing. 

  

Zing Specifications

Zing Portable Size 1- is designed to accommodate most individuals up to 36" (91 cm) and up to 36 lbs. (16 kg).

Overall dimensions of Zing Portable Size 1 (approximate):

Dimensions: 32"x38.5"x33.5" (815 x 980 x 850 mm)

Weight: 19 lbs (8.6 kg)

 Dimensions and weight may vary according to the set-up configuration and accessories used.

For more detailed specifications visit our website www.zingstanders.com

•   The Zing should not be used without first consulting a qualified physician. Failure to consult a qualified physician prior 

 

to using the Zing could lead to severe medical problems. We recommend a good standing program be established and 

 

supervised by a qualified, registered physical/occupational therapist.

•   The Zing should always be used with a qualified adult attendant present. Consult with your therapist or physician for proper foot 

 

placement and angle. Never leave a child unattended in the Zing.

•   Do not make foot plate adjustments to the Zing while a child is standing. Changes in position must be performed or supervised by a 

 

qualified caregiver or medical professional .

 

•   It is necessary to inspect your Zing at least weekly to ensure it is in safe operating condition. Pay particular attention for loose 

 

hardware. Replacement of worn parts, major adjustments, or any other important corrections should be handled by an authorized dealer 

 

or service center. Only Altimate Medical, Inc. approved replacement parts should be used to ensure safety and performance.

•  If your Zing is being used in the home environment, please inspect your unit prior to each use to ensure there is no damage or 

 

unexpected wear to the Zing that may have been caused unintentionally by pets, pests or children.      

•   Ensure the necessary support and alignment options are in position prior to placing the user into the standing position.  

•  If the unit was exposed to temperatures of less than 50˚F (23.5˚C), allow unit to warm to room temperature before use. In addition, if the 

 

unit has been exposed to higher than normal room temperatures, allow sufficient time for the unit to adequately acclimate to room 

 

temperature. Ensure that no surfaces are uncomfortable to touch before placing a child in the unit.

•  Operating Conditions: Temperature: 41˚F -104˚F (5˚C-+40˚C), Relative humidity: 15% - 90% at 86˚F (30˚C), Atmospheric Pressure: 700 

 

to 1060hPa.

•  Storage/Transport Conditions: Temperature: -13˚F -158˚F (-25˚C-+70˚C), Relative humidity: 15% - 90% at 86˚F (30˚C), Atmospheric 

 

Pressure: 700 to 1060hPa.

•  The Altimate Medical Standing Products can be used at a maximum altitude of 10,000 feet (3,050 meters).
•  The expected service life of a Zing is considered 5 years under normal use conditions. Note: This may vary based on frequency of use. 
•   Standing equipment is designed for indoor use on level surfaces only.  

•     The Zing Portable Stander may be easily moved or transported by folding the tripod legs and grasping the integral carrying handle. Never 

 

attempt to move or carry the unit with a child in the stander. After transport inspect the unit to ensure hardware is properly tightened and 

 

all options are secured. 

•  Extreme movements laterally or front to back may cause the unit to tip.    
•   It is recommended the equipment be stored at normal room temperature and humidity levels. 
•   Altimate Medical products are specifically designed to be used with Altimate Medical accessories and options. Unless otherwise noted, 

 

accessories and options from other manufacturers have not been tested by Altimate Medical and are not recommended for use with 

 

Altimate Medical products.

•  Product Modifications made without express written consent (including, but not limited to, modification through the use of unauthorized 

 

parts or attachments) are not recommended and will void the product warranty.  

 

Caution: Altimate Medical Standing Products are constructed of materials that do not support combustion under normal conditions. For 

 

the safety of the patient and attending personnel, do not allow clutter or debris to be stored or accumulate on or around the equipment.

 Caution: This equipment is designed to accommodate a range of users; therefore the unit has various adjustment slots and holes. 

 

Avoid placing fingers or other body parts in any of these areas.  

 Caution: While in use this equipment has various moving parts, familiarize yourself with the unit and avoid placing hands or fingers 

 

near any of these areas.  

 Caution: Advise bystanders to keep clear of the unit while in use.

 Caution: As with any upholstered equipment, smoking in or around the product or exposing it to a direct source of ignition such as a 

 

space heater or fire is not recommended.

Safety Precautions  

Folding

18. Depress snap button. Carefully push up on the 

locking mechanism to bring the legs in.

Caution: Make sure not to pinch fingers.

Summary of Contents for Altimate Medical Zing

Page 1: ... guidance of a physician with recommendations for standing program protocol and any medical precautions Standing programs should be monitored by the attending therapist Altimate Medical maintains a policy of continual product im provement and reserves the right to change features specifications and prices without prior notification Check with Altimate Medical for latest information FORM ZINGPORT1 ...

Page 2: ...ER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR AND OR REPLACEMENT This warranty does not include any labor charges incurred in replacement parts installation Freight charges to factory are at the expense of consumer to seller Return freight charges will be prepaid by Altimate Medical For warranty service please contact the authorized supplier from whom you purchased your Altimate Medical product...

Page 3: ...nts that are listed in the product owner s manual can be made by the operator by following the instructions for use After an adjustment is made inspect the Zing to ensure all hardware and adjustable components are properly secured per the instructions for use Replacement of worn parts major adjustments or any other important corrections should be handled by an authorized supplier or service center...

Page 4: ... allow unit to warm to room temperature before use In addition if the unit has been exposed to higher than normal room temperatures allow sufficient time for the unit to adequately acclimate to room temperature Ensure that no surfaces are uncomfortable to touch before placing a child in the unit Operating Conditions Temperature 41 F 104 F 5 C 40 C Relative humidity 15 90 at 86 F 30 C Atmospheric P...

Page 5: ...n a multiple user environment the Zing should be cleaned after each use Urethane Coated Fabrics and Hygienic Washable Covers Dartex or generic equivalent The recommended cleaning and disinfection instructions should be followed whenever possible to avoid damage to the PU membrane which could lead to premature failure of the cover For superficial dirt use a disposable wipe and a warm solution of ne...

Page 6: ...he patient Patients who may be hyper sensitive or susceptible to Allergic Contact Dermatitis should be monitored closely until it is known if a reaction may occur There is no natural latex used in any materials in the Zing Portable stander Upholstery materials used include polyester nylon neoprene and polyurethane Upholstery and Upholstery Straps Page 3 Assembly 1 Remove the base from the box and ...

Page 7: ...en knob securely To adjust the head support depth loosen knob and set to desired position Tighten knob securely 11 To adjust the Toe in Toe out Abduction loosen knobs underneath foot plates slide foot plates into position Tighten knobs securely Height Adjustment Knob Depth Adjustment Knob 4 Locate the rubber washer on each of the abduction bolts 5 Remove only the rubber washer on both abduction bo...

Page 8: ...knee pad position loosen knob and move or rotate to desired position Tighten securely Height Adjustment Knob Depth Adjustment Knob Pad Adjustment Knob 7 There are 4 pads 3 pads have straps on them they are the pelvic support pad supine upper body support pad and prone upper body support pad The other pad without the strap is the head sup port Remove 2 bolts from the parts bag and place one of the ...

Page 9: ...oosen the knob under the table set to desired position Tighten knob securely Knob Page 13 10 Remove 2 small knobs and washers from the parts bag Place washer onto the tray bracket as shown 11 Place knob onto tray bracket only start the threads you will tighten the knob later on Repeat steps for other side of the tray bracket 12 Using 2 bolts from the parts bag place the supine upper body support p...

Page 10: ...peat steps for other foot plate Page 12 Adjustment Usage 13 Place the head support bracket into the tube as shown Depress the spring button 14 While supporting the head support bracket place one of the large knobs from the parts bag onto the unit as shown Tighten securely 15 Remove 2 bolts from the head support pad the head support pad does not have straps Place pad onto head support pad bracket a...

Page 11: ...11 16 Place the head support pad bracket into the tube on the head support bracket as shown and tighten knob securely 17 Using the lever with one hand and supporting the unit with your other hand position the unit as shown 18 Depress the spring button on the leg and insert knee pads onto tube as shown Make sure the knobs are positioned as shown below Page 8 ...

Page 12: ... leg and insert foot plate onto tube as shown Put into position and tighten securely Repeat steps for other foot plate 21 Loosen tray knobs 22 Place tray as shown 23 Tighten both tray knobs securely 24 Place prone tray as shown Loosen knob on the side of the tray and position the bracket vertical Tighten knob securely Page 10 Page 9 ...

Page 13: ... leg and insert foot plate onto tube as shown Put into position and tighten securely Repeat steps for other foot plate 21 Loosen tray knobs 22 Place tray as shown 23 Tighten both tray knobs securely 24 Place prone tray as shown Loosen knob on the side of the tray and position the bracket vertical Tighten knob securely Page 10 Page 9 ...

Page 14: ...11 16 Place the head support pad bracket into the tube on the head support bracket as shown and tighten knob securely 17 Using the lever with one hand and supporting the unit with your other hand position the unit as shown 18 Depress the spring button on the leg and insert knee pads onto tube as shown Make sure the knobs are positioned as shown below Page 8 ...

Page 15: ...peat steps for other foot plate Page 12 Adjustment Usage 13 Place the head support bracket into the tube as shown Depress the spring button 14 While supporting the head support bracket place one of the large knobs from the parts bag onto the unit as shown Tighten securely 15 Remove 2 bolts from the head support pad the head support pad does not have straps Place pad onto head support pad bracket a...

Page 16: ...oosen the knob under the table set to desired position Tighten knob securely Knob Page 13 10 Remove 2 small knobs and washers from the parts bag Place washer onto the tray bracket as shown 11 Place knob onto tray bracket only start the threads you will tighten the knob later on Repeat steps for other side of the tray bracket 12 Using 2 bolts from the parts bag place the supine upper body support p...

Page 17: ...knee pad position loosen knob and move or rotate to desired position Tighten securely Height Adjustment Knob Depth Adjustment Knob Pad Adjustment Knob 7 There are 4 pads 3 pads have straps on them they are the pelvic support pad supine upper body support pad and prone upper body support pad The other pad without the strap is the head sup port Remove 2 bolts from the parts bag and place one of the ...

Page 18: ...en knob securely To adjust the head support depth loosen knob and set to desired position Tighten knob securely 11 To adjust the Toe in Toe out Abduction loosen knobs underneath foot plates slide foot plates into position Tighten knobs securely Height Adjustment Knob Depth Adjustment Knob 4 Locate the rubber washer on each of the abduction bolts 5 Remove only the rubber washer on both abduction bo...

Page 19: ...he patient Patients who may be hyper sensitive or susceptible to Allergic Contact Dermatitis should be monitored closely until it is known if a reaction may occur There is no natural latex used in any materials in the Zing Portable stander Upholstery materials used include polyester nylon neoprene and polyurethane Upholstery and Upholstery Straps Page 3 Assembly 1 Remove the base from the box and ...

Page 20: ... allow unit to warm to room temperature before use In addition if the unit has been exposed to higher than normal room temperatures allow sufficient time for the unit to adequately acclimate to room temperature Ensure that no surfaces are uncomfortable to touch before placing a child in the unit Operating Conditions Temperature 41 F 104 F 5 C 40 C Relative humidity 15 90 at 86 F 30 C Atmospheric P...

Page 21: ...nts that are listed in the product owner s manual can be made by the operator by following the instructions for use After an adjustment is made inspect the Zing to ensure all hardware and adjustable components are properly secured per the instructions for use Replacement of worn parts major adjustments or any other important corrections should be handled by an authorized supplier or service center...

Page 22: ...n a multiple user environment the Zing should be cleaned after each use Urethane Coated Fabrics and Hygienic Washable Covers Dartex or generic equivalent The recommended cleaning and disinfection instructions should be followed whenever possible to avoid damage to the PU membrane which could lead to premature failure of the cover For superficial dirt use a disposable wipe and a warm solution of ne...

Page 23: ...ER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR AND OR REPLACEMENT This warranty does not include any labor charges incurred in replacement parts installation Freight charges to factory are at the expense of consumer to seller Return freight charges will be prepaid by Altimate Medical For warranty service please contact the authorized supplier from whom you purchased your Altimate Medical product...

Page 24: ... guidance of a physician with recommendations for standing program protocol and any medical precautions Standing programs should be monitored by the attending therapist Altimate Medical maintains a policy of continual product im provement and reserves the right to change features specifications and prices without prior notification Check with Altimate Medical for latest information FORM ZINGPORT1 ...