background image

Reinstall head over valve plate(s) checking 

that orientation with ports is correct. Torque 

screws to 50 inch-pounds

Remove old and install new head o-rings in 

the o-ring grooves on top of valve plate

Press retainer plate with piston cup into cyl-

inder all the way to the piston. The cylinder 

can be rotated to align the screw holes. Ap-

ply thread locking compound (Loctite

®

 222) 

to retainer screws, torque screws to 10-13 

inch-pounds.

Check that orientation of the valve plate(s) 

with ports is correct and place over 

cylinders.

7.

10.

Stratus SRC Series Repair Kit Instructions

(800) 448-3873 • Grant, MI 49327 • www.easypropondproducts.com

9156 - 5/17

Unit must be unplugged 

before servicing

Inspect the leaf valves for damage or wear. 

NOTE: There is one intentionally “bent” 

leaf valve per set. If leaf valves need to be 

replaced, a complete leaf valve plate can be 

ordered. The screws holding the leaf valves 

are susceptible to breaking which makes in-

dividual leaf valve replacement very difficult.

Remove the cylinder o-ring(s) from the bot-

tom of valve plate(s) and install new o-rings.

9.

8.

12.

11.

Visit easypropondproducts.com/resources for more information

Check that all external accessories such as relief valves and gauges are not damaged before re-operating product.