background image

Installation

•   Do not paint casing, over heating may occur
•  Lift only by handle, not by power cable or float switch
•  Do not hang pump in water, install on solid flat base in upright or 

horizontal position

•  Install proper outlet adapter for pipe or hose
•  Make sure that power cable plug and power outlet are away from 

water and water discharge pipe/hose.

Operation

1. 

Do not start operation with people standing near intake or 

outlet.

2.  Do not operate out of water.
3.  Pump must remain fully submersed.
4.  Only use pump for circulation, transfer or removal of water with limit-

ed solids 

1

/

4

" or smaller.

5.  Do not pump oil, salt water, sewage, food or chemical liquids.
6.  Do not allow dry operation
7.  Do not allow foreign objects to clog or enter intake
8.  In case of power outage, turn off power switch to avoid damage when 

power is restarted.

9.  If excessive vibration occurs turn off power immediately.

Service & Maintenance

1.  

Disconnect all power supplies before inspection or service to 

avoid possible electrical shock.

2.   The pump should be removed from the pond on a regular basis, 

cleaned and checked over for damage to prolong the life of the pump.

3.   Clean the impeller and intake screen when the flow is visibly reduced.
4.   Clean the pump and impeller with clean fresh water.
5.   Check inside the impeller housing for large debris or algae, which 

could reduce the flow.

6.   Check and tighten nuts and bolts if required, refer to dealer for advice 

on other repairs.

7.  Winterization/Storage: When the pump is out of use for extended time 

- wash and dry it then store indoors in a non-freezing location. It is 

best to store in a bucket with about an 8" water depth. It is essential 

to prevent any risk of the pump freezing.

8.  If the pump is left in water but not operating regularly, test run it at 

least once a week.

Summary of Contents for Spirit TLS1850

Page 1: ...tuary Just A Falls etc A great choice for ponds with light debris laden water Specifications Can be run in vertical or horizontal positions for compact applications Oil less design fish and plant safe Impeller designed for passing debris up to 1 4 diameter 11 4 female threaded outlet with a 11 4 x 11 2 elbow included Triple sealed 115v motors with 18 month warranty Automatic overload and thermal p...

Page 2: ...ualified technician Always follow the National Electrical Code NEC or the Canadian Electrical Code as well as all local state and provincial codes Code questions should be directed to your local electrical inspector Failure to follow electrical codes and OSHA safety standards may result in personal injury or equipment damage Failure to follow manufactur er s installation instructions may result in...

Page 3: ...id damage when power is restarted 9 If excessive vibration occurs turn off power immediately Service Maintenance 1 Disconnect all power supplies before inspection or service to avoid possible electrical shock 2 The pump should be removed from the pond on a regular basis cleaned and checked over for damage to prolong the life of the pump 3 Clean the impeller and intake screen when the flow is visib...

Page 4: ... specifications Water level is too low Running very Pump is air locked start and stop several times by little water plugging and unplugging cord check for clogged vent hole Vertical pumping distance is too high or the pipe size is too small Inlet or impeller clogged Low water conditions with pump sucking air GFCI breaker Mechanical seals may need to be replaced tripping Power cord may be damaged a...

Page 5: ...ity GPM TLS1850 TLS2750 TLS4250 EasyPro TLS Pump Performance 35 Discharge 11 4 fpt Elbow 11 2 fpt Voltage 115v 60 hz Power Cord 20 Part Maximum Gph Hp Watts Maximum Head TLS1850 1850 1 4 260 21 TLS2750 2750 1 3 370 29 TLS4250 4250 1 2 820 33 Specifications ...

Page 6: ...able for any damag es caused by defective components or materials of this pump or for loss incurred because of the interruption of service or any conse quential incidental damages and expenses arising from the produc tion sale use or misuse of this product The manufacturer or supplier shall not be held liable for any loss of fish plants or any other livestock as a result of any failure or defect o...