background image

PCA SERIES PUMPS

Reliability You Can Count On!

www.easypro.com • 800-448-3873

© 2019 EasyPro, Inc

5730 • 10/19

 — Pg. 2

 IN THE USA

ASSEMBLED

WARNINGS

1.  This pump and motor unit should be installed by a qualified electrician or serviceman in accordance with all applicable state and local codes and 

ordinances, and in accordance with the National Electrical Code. Improper installation may create a mechanical or electrical hazard which could 

cause damage to property and which could result in serious injury or death. Always follow the schematic on the motor for all electrical connections! 

2.  In order to avoid serious injury or death, always disconnect power to the motor before servicing the pump.
3.  Never run the pump dry. You must fill the priming pot (volute) with water before starting the motor. 
4.  Never start the pump when the motor shaft is turning. To prevent unwanted motor rotation, install a swing type check valve.
5.  If you are not competent to install the pump, get help from a qualified source.
6.  Maintain a minimum flow rate of two gallons per minute.
7.  Visually inspect the pump and motor once a month. If there is any leakage from the shaft seal, replace it at once. The seal faces wear (just like car 

tires) and must be replaced periodically. For critical applications, replace the shaft seal yearly.

8. For 3 phase motors, insure correct motor r otation. See item 7 in electrical for details.

INSTALLATION
General

Proper installation of your PCA Series pump will help insure years of trouble free service.
1.  Position the pump as near to the water and as low as is practical. This will help reduce priming time, avoid cavitation and maximize your pumps 

performance. Do not allow pump to become submerged.

2.  Minimize friction losses by using large diameter pipe, reducing the length of runs and minimizing the number of elbows and fittings as much as 

possible.

3.  Protect the motor from excessive heat. It is best to provide shade from direct sun, and insure that it has proper ventilation. Excessive heat will 

shorten the motors life and void the warranty.

4.  Protect the motor against dirt, water and all foreign matter. If the motor has been flooded, do not operate it until it has been checked by an 

authorized motor technician and has been found to be safe to operate. If the motor is damaged by dirt, moisture or corrosion it voids the warranty.

5.  Mount the motor to a stable base where it will not get submerged.
6.  The pump ports are 3" on both the inlet and discharge ports. PVC fittings are available to accommodate 2", 2

1

/

2

" and 3" pipe. Quick connect 

unions are included with each pump. All plumbing lines should be self supported and properly aligned. This will prevent undue stress to the 

housing. Use a suitable PVC primer and cement to connect your pipe to the fittings.

7.  Installations in which the discharge pipe is elevated above the pump must use a swing type check valve to prevent back flow and possible reverse 

rotation. 

Electrical

1.  If you are not competent to wire an electric motor, hire someone who is!
2.  Make sure the power is disconnected at the breaker before wiring the motor. 
3.  Make sure that the motor is wired internally so that it matches the supply voltage. If they do not match, it will damage your motor and void the 

warranty (i.e. if you are connecting it to a 115v breaker, make sure the motor connections match the 115v (low) wiring diagram found on the motor). 

Always follow the schematic on the motor for all electrical connections.

NOTE: Baldor

 motors have sepeate wiring schematics for low 115v and high 230v applications. Both schematics are shown for dual voltage motors. 

AO Smith 

Motors use a switch to change between low 115v and high 230v on dual voltage motors. This switch is located under the rear cover on the 

back of the motor. The wiring schematic is the same for these motors since the switch determines the voltage selected.
4.  Use a supply wire of adequate gauge to prevent electrical line losses. The use of heavier gauge wire will allow the motor to run cooler and more 

efficiently by eliminating excessive line voltage loss. 

5.  Make sure all connections are clean and tight. Properly ground the motor. (There is normally a green ground terminal located inside the motor 

connection box.) Make sure the ground wire is properly connected to an electrical service ground. 

6.  Connect the pump permanently to an adequately sized circuit. It is best to have a dedicated circuit that will not suffer a voltage drop from other loads.
7.  When using three phase power the motor leads must be energized in the correct sequence to provide proper motor rotation. When viewed from 

the shaft end the motor must rotate counterclockwise. Incorrect rotation will destroy the pump and motor and void the warranty. If you are not sure 

of the sequence of your incoming supply lines, remove the volute (front housing) and diffuser from the pump, then connect the power and check 

rotation. If it is incorrect exchange any two of the connected leads and retest. When the rotation is correct reinstall the diffuser and volute.

*Never test rotation by bumping a connected electrical switch. This will destroy the pump and void the warranty!

Summary of Contents for PCA75

Page 1: ... 5 3 5 HP 208 230V PORT SIZE 3 SPIGOT WITH UNIONS HORSEPOWER 75 1 5 3 5 HP SEAL STATIONARY TYPE STAINLESS STEEL WITH BUNA TRIM FOR 5 8 SHAFT CORD 75 HP INCLUDES 6 115V CORD NO CORD ON OTHERS WARNING Please read completely before you install or operate your new pump Do NOT allow this pump to become submerged Never run dry and never reverse rotation Thank you for purchasing the PCA Series Pump from ...

Page 2: ...ts PVC fittings are available to accommodate 2 21 2 and 3 pipe Quick connect unions are included with each pump All plumbing lines should be self supported and properly aligned This will prevent undue stress to the housing Use a suitable PVC primer and cement to connect your pipe to the fittings 7 Installations in which the discharge pipe is elevated above the pump must use a swing type check valv...

Page 3: ... box For high voltage 1 Connect your incoming hot lead normally the black wire to wire 1 2 Connect your other hot lead normally the white wire to wire 4 3 Connect wire 2 and 3 together 4 Tape off the wire marked J 5 Use appropriately sized wire nuts to insure all connections are secure and insulated 6 Connect your ground lead normally green to the green screw in the connection box Note Your motor ...

Page 4: ...k impeller hub with a small straight screw driver 10 Clean the bracket seal bore housing and the motor shaft as necessary PUMP ASSEMBLY 1 To install a new shaft seal clean or replace the o ring in the bore If there is no o ring clean the bore and apply a bead of 100 silicon sealant inside the bore and around the top edge 2 Press the seal into the bore without touching or putting pressure on the de...

Page 5: ...e open Ensure plumbing is clear including suction strainers check valves etc Clean out leaves or other debris from basket strainer if applicable Insufficient Prime Prime system with water and purge all air from suction piping Cavitation Verify airtight plumbing on the suction plumbing especially fittings Clean out leaves or other debris from basket strainer if applicable Increase pipe size where p...

Page 6: ...ty For applications that involve fluids other than water the purchaser shall retain and present to EasyPro Pond Products evidence of purchaser s compatibility tests under actual operating conditions Any problems caused by a chemical incompatibility of the fluid with the pump materials are expressly not covered by this warranty No warranty whatsoever of chemical compatibility or application suitabi...

Reviews: