Compressor Placement

It is critical that the air compressors be protected from the weather. You will 

need to provide a shelter for your compressor to protect it from rain, snow and 

other harsh elements.
•  Be sure your shelter is adequately ventilated. A cooling fan may be 

necessary in warmer climates. Several cabinet options with fans are 

available.

•  Be sure the compressor does not sit directly on the ground, as the vibration 

from the motor will cause dust and dirt particles to be pulled into the motor 

and may cause premature failure. NOTE — Avoid areas with excessive 

dust, this can damage compressor.

•  If operating compressor in freezing climates do not place compressor 

in “heated” buildings. Warm air holds more moisture. This warm air may 

condensate and freeze in the colder outdoor 

line. 

•  Ensure that compressors are placed where 

they will not become flooded with water.

•  If possible, shaded areas are preferred.
•  In areas with limited electrical supply, 

compressors can be placed long distances 

from the pond edge. A remote access valve 

assembly can be fed from the compressor with properly sized tubing.

Cabinet Placement

•  If installing a Sentinel Deluxe Aeration System, place the cabinet on a level, 

unobstructed base to ensure the compressor does not overheat.

•  A post mounted cabinet should be kept free from high weeds and other 

obstructions to ventilation system.

Diffuser Placement

The amount of surface area an aeration system will effectively cover is greatly 

dependent on two factors - DEPTH and SHAPE. The deeper an air diffuser is 

located, the more boiling action it will create and a larger area will be aerated. 

The diagram below shows how much surface area is effectively aerated per 

air diffuser at various depths. Ponds that are irregular or odd shaped will also 

reduce size of aeration area — call our technical department for  

additional help.

Example:
Our PA34 pond aerator 

would aerate only 

1

/

8

 

of an acre if operated 

in 4' deep water, while 

aerating up to 1 acre if 

operating in 12' - 16' deep 

water.

The shape of a pond affects 

the amount of diffusers 

needed. Irregular shaped 

ponds often require multiple 

diffusers to adequately aerate 

entire water column.

Up

 to

 1

1

/

2

 acr

es in 16' - 20' dee

p w

ate

r

U

to

 1 

acr

e in 1

2' - 16' de

ep w

ate

r

U

to

 

1

/

2

 ac

re in

 8' - 12' d

eep

 w

ate

r

Up

 to

 

1

/

4

 a

cr

e in

 5' - 8' d

ee

p w

ate

r

Air Diffuser

Summary of Contents for PA10

Page 1: ...Diaphragm Rotary Vane Aeration Systems Diffused Aeration Systems Installation Operation Maintenance Guidelines Save this booklet for future reference Manuals also available at www easypro com ...

Page 2: ...ompressors to run 24 hours per day for three to five years The only maintenance required is replacement of wearable items diaphram piston ring vanes etc when needed and keeping filter clean CAUTION All compressors in these kits are designed for oil free operation Never oil or lubricate the compressors In addition to adding oxygen to your pond an aeration system creates a circulation action It take...

Page 3: ...nstaller and others Aeration System Details Kit Maximum Maximum Diffuser Cabinet Part Pond Size Recommended Depth Assembly Compatibility PA10 1 4 Acre 12 DM2 SC18 SC22 SC25 PA12 1 4 Acre 30 DM2 SC18 SC22 SC25 PA50 2 Acres 18 Two QS2 SC22 SC25 PA75 4 Acres 18 Four QS2 SC22 PA100 6 Acres 18 Six QS2 SC22 Factors such as pond depth and pond shape will affect maximum pond size Replacement 6 rubber memb...

Page 4: ...or with properly sized tubing Cabinet Placement If installing a Sentinel Deluxe Aeration System place the cabinet on a level unobstructed base to ensure the compressor does not overheat A post mounted cabinet should be kept free from high weeds and other obstructions to ventilation system Diffuser Placement The amount of surface area an aeration system will effectively cover is greatly dependent o...

Page 5: ...PA10 and PA12 systems are a single line with no valve See images for reference of your system 4a For PA10 style kits 1 20 hp DC22 Compressor 4b For PA12 style kits 1 8 hp DC12 Compressor 4c For PA50 75 100 style kits 1 4 3 4 and 1 hp Rotary Vane Compressors 5 Unroll the entire roll of tubing It is recommended that the diffuser be installed at this point This will allow you to trim any unused tubin...

Page 6: ...ormance Be sure to keep the air filter clean Replacement filters are available Kit Replacement Compressor Part Compressor Filter Element Repair Kits PA10 DC22 DC22F RK22 PA12 DC12 ERPF1 ERPF12E DC12RK PA50 RV33 AC432 AC393 RV33V PA75 RV75 AC432 AC393 RV75V PA100 RV100 AC432 AC393 RV100V Troubleshooting Compressor Troubleshooting Low High Compressor Excess Pressure Pressure Overheating Noise Cause ...

Page 7: ...t or parts covered under this warranty Making a Claim A Return Authorization RA number must first be obtained by calling EasyPro at 800 448 3873 or via email at warranty easypro com It is the purchaser s responsibility to pay the return shipping charges Be sure to include the RA number original receipt in the form of an invoice or sales receipt your name your return address and your phone number i...

Page 8: ...eria is designed to Reduce oxygen demand and sludge buildup Eliminate excess nutrients and pond odors Improve water clarity Available in 10 lb and 25 lb pails with 8 oz water soluble packs or loose powder in 25 lb pails and 100 lb drums EasyPro Sludge Remover Pellets Bacteria specifically designed to reduce sludge on the pond bottom Great for spot treating around docks and beach areas Available in...

Reviews: