10.    All electrical work must be performed by a qualified technician. Always follow the 

National Electrical Code (NEC) or the Canadian Electrical Code as well as all local, 

state and provincial codes. Code questions should be directed to your local electrical 

inspector. Failure to follow electrical codes and OSHA safety standards may result 

in personal injury or equipment damage. Failure to follow manufacturer’s installation 

instructions may result in electrical shock, fire hazard, personal injury or death, damaged 

equipment, provide unsatisfactory performance and may void manufacturer’s warranty.

11.   Do not carry or lift the pump by the power cord.
12.    Never use an extension cord or tamper with power cord. Power cord should not become 

bent, twisted, abraded or cut. A damaged cable may cause electric leakage, shock or 

fire. The power cord cannot be replaced, and unit should be replaced if cord becomes 

damaged.

13.   Do not remove the pre-filter housing during operation of the pump. 

Features

• Permanent magnet motor for high efficiency and long life.
• Oil-less design is safe for fish and plants
• Impeller designed for passing debris up to 3/8" diameter
• Adjustable direction outlet for use with 1", 1 1/4" or 1 1/2" kink free or 1 1/2" PVC tubing
• Ceramic impeller provides high wear resistance and long life
• Epoxy sealed motor is waterproof, safe and reliable
• Pump can be run continuously 24 hours per day.

Assembly and General Installation

1.  The pump can be placed at the bottom of the pond. One end of the hose will connect to the 

pump outlet and the other will feed a filter or waterfall device. 

2.  Maximum performance is achieved when used with largest outlets and tubing sizes available. 

Restricting water flow with small accessories will reduce the performance of the pump.

3. Select the step barb fitting or the PVC adaptor fitting based on type of tubing being used. 
4.  When using the step barb fitting, use a hacksaw to remove 

any smaller steps than the tubing being used.

5.  Secure the adjustable ball joint fitting to the pump outlet 

and attach the appropriate tubing adapter by hand 

tightening the locking nuts. 

6.  Secure tubing to adapters. Use clamps (not included) 

on barb fittings or rubber coupler (not included) for PVC 

adaptor fitting. 

7.  When moving the pump be sure to lift only by handle and 

not by power cable.

8.  Place the pump on a flat brick or stone on the pond bottom. This keeps the pump out of the 

sludge and prevents excess debris from entering the pump.

Step 4

Cut here for

1 1/4" tubing

Cut here for

1 1/2" tubing

Summary of Contents for Eco-Clear EPS1300

Page 1: ...ical supply before handling maintaining repairing or installing any pond equipment 2 Keep out of the reach of children 3 Always make sure you know the correct amps and voltage required before installing 4 Use dedicated power outlet only Sharing the outlet with other equipment may cause overheating and fire 5 A drip loop should be installed in the power cord to ensure water cannot travel down it an...

Page 2: ...direction outlet for use with 1 1 1 4 or 1 1 2 kink free or 1 1 2 PVC tubing Ceramic impeller provides high wear resistance and long life Epoxy sealed motor is waterproof safe and reliable Pump can be run continuously 24 hours per day Assembly and General Installation 1 The pump can be placed at the bottom of the pond One end of the hose will connect to the pump outlet and the other will feed a fi...

Page 3: ...using is closed and properly latched to prevent debris from entering the pump 4 Check the water level daily to ensure the pump remains fully submerged 5 If the pump is left in water but not operating regularly test run it at least once a week 6 Once per season the unit should be disassembled to clean any build up of debris or mineral deposits on the impeller assembly and housing Areas with hard wa...

Page 4: ...access the impeller assembly remove four screws from pump impeller housing 10 Carefully pull the impeller out of its chamber 11 Inspect and clean the impeller and chamber Clean the impeller and chamber using water and a damp cloth or sponge A vinegar mixture may help remove hard deposits If the impeller is damaged replace with a new impeller 12 Once the impeller is cleaned or replaced with new one...

Page 5: ...ing very little water Check pump housing or impeller for clogs Check tubing for kinks or obstructions Vertical pumping distance is too high or the pipe size is too small Pond filter needs to be cleaned Low water conditions with pump sucking air For the EPS4900VF adjust flow with the controller It may be necessary to increase the flow volume temporarily and once running smoothly the flow can be low...

Page 6: ...LEAR PUMP PERFORMANCE DATA Model 0 3 6 9 12 15 18 21 24 COMPATIBLE ECO CLEAR FILTER EPS1300 1400 1125 710 430 150 EC1300 EC1300U EPS2500 2480 1680 1140 815 449 185 EC2600 EC2600U EPS3700 3680 2900 2310 1815 1390 875 180 EC3900 EC3900U EPS4900 4850 4090 3215 2425 1800 1400 832 195 EPS4900VF 4850 4090 3215 2425 1800 1400 832 195 Gallons per hour gph flow at feet of head Pro Tip Maximum performance i...

Page 7: ...VF pump EPSBK Hose barb replacement Barb Hose Connector Nut Gasket EPSRB Adjustable Rotating Ball Connector with Nut and Gasket EPSPB Pump Bracket Set Includes Large and Small Bracket No screws EC150PVC 1 1 2 Adapter Fitting for PVC not shown Replacement Parts Image for reference only Upper Housing Locking Clip Nut Large Bracket Barb Hose Connector Gasket Adjustable Ball Gasket Pump Small Bracket ...

Page 8: ...st first be obtained by calling EasyPro at 800 448 3873 or via email at warranty easypro com It is the purchaser s responsibility to pay the return shipping charges Be sure to include the RA number original receipt in the form of an invoice or sales receipt your name your return address and your phone number inside of the package No warranty claims will be honored without the original receipt that...