To  enable  the  extended  menu  functions  proceed  as  follows: 
press  and  hold  the  SET  button  for  5  seconds;  the  SUN  and 
RAIN LEDs will start flashing alternately. the user then has 30 
seconds in which to select the extended menu functions using 
the  SEL  and  SET  buttons.  After  30  seconds  the  control  unit 
returns to the main menu.

 

 

---------------------- EXTENDED MENU -----------------

 

Reference LED                LED Off                              LED On

 

A) CODE           remote PGM = OFF                      remote PGM = 
ON

 

2)  SENS.  CODE      Wired  sensor  Test  = OFF   Wired sensor Test = 
ON     

 

C) T. MOT.        Aut. movement lock = OFF    Aut. movement lock = 
ON

 

D) WIND SPEED       Safety upward = OFF        Safety upward = ON

 

E) SUN SENSOR     SUN inversion = OFF        SUN inversion = ON

 

F) RAIN SENSOR    RAIN inversion = OFF       RAIN inversion = ON

 

G) SUN                                   Flashing beacon ON/OFF                 

 

H) RAIN                                   Flashing beacon ON/OFF                

 

 
A) CODE  
(Remote programming of radio control): 
The  control  unit  allows  the  transmission  code  to  be  pro-
grammed  remotely,  without  using  the  SEL  button  on  the  unit 
itself. 
To  programme  a  transmission  code  remotely,  proceed  as  fol-
lows:  send  the  radio  control  code  continuously  for  more  than 
10  seconds;  the  control  unit  will  enter  the  programming  mode 
as described above for the CODE LED in the main menu.

 

The  control  unit  is  supplied  by  the  manufacturer  with  remote 
programming  of  a  transmission  code  not  enabled;  to  enable 
the function proceed as follows: check that the extended menu 
is  enabled  (SUN  and  RAIN  LEDs  flash  alternately),  use  the 
SEL button to navigate to CODE LED when flashing and press 
the  SET  button:  the  CODE  LED  lights  up  and  programming is 
complete.  Repeat  the  procedure  to  restore  the  previous  con-
figuration.

 

 
B) SENS. CODE (Wired sensor test):

 

The control unit can be used to check the operation of the con-
nected sensors, and to make sure the rotation direction is cor-
rect.  When  installing  the  device,  we  recommend  the  blind  is 
placed in an intermediate position so that you can see all con-
firmation  movements  during  the  test  procedures.  After  check-
ing the sensors are operating correctly, you must remember to 
disable the Wired sensor test.

 

Anemometer: manually rotate the Anemometer blades; at the 
same  time,  the  control  unit  will  cause  an  upward  movement 
lasting 5 seconds.

 

Sun sensor test: expose the Sun sensor to natural or artificial 
light; at the same time, the control unit will cause the SUN LED 
to  light  up  and  there  will  be  a  downward  movement  lasting  5 
seconds.  Block  the  Sun  sensor;  at  the  same  time,  the  control 
unit will cause the SUN LED to switch off and there will be an 
upward movement lasting 5 seconds.

 

Rain sensor test: wet the sensitive part of the Rain sensor; at 
the same time, the control unit will cause the RAIN LED to light 
up  and  there  will  be  an  upward  movement  lasting  5  seconds. 
When you have completed the test, make sure you have dried 
the  sensitive  part  of  the  Rain  sensor  before  using  the  control 
unit in its normal operating mode. 

 

Programming:  The  control  unit  is  supplied  by  the  manufac-
turer with the Wired sensor test disabled. If you wish to enable 
the  Wired  sensor  test,  proceed  as  follows:  check  that  the  ex-
tended  menu  is  enabled  (SUN  and  RAIN  LEDs  flash  alter-
nately),  use  the  “SEL”  button  to  navigate  to  SENSOR  CODE 
LED  when  flashing  and  press  the  “SET”  button:  the  SENSOR 
CODE LED lights up and programming is complete. Repeat the 
procedure to restore the initial configuration.

 

Important: for information on the Wireless sensor test, please 
refer to the Wireless sensor manual.

 

 

C) T. MOT.  (Automatic Movement Lock):

 

The  control  unit  enables  the  prevention  of  automatic  move-
ments  (Up  /  Down  sun  blind  movements  on  the  Sun  Sensor 
command  or  Automatic  Sensors  function),  so  that  if  a  Stop 
command  is  sent  from  a  radio  control  during  movement,  the 
control unit momentarily locks the Automatic movements until a 
new Up or Down command is sent. The control unit is supplied 
by  the  manufacturer  with  the  Automatic  Movement  Lock  dis-
abled; to enable the function proceed as follows: check that the 
extended  menu  is  enabled  (SUN  and  RAIN  LEDs  flash  alter-
nately). Using the “SEL” button, navigate to T.MOT LED when 
flashing and press the “SET” button: the T.MOT LED lights up 
and programming is complete. Repeat the procedure to restore 
the previous configuration.

 

 
D) WIND SPEED (Safety upward movement): 
The control unit is supplied by the manufacturer with the Safety 
upward  movement function disabled; if you wish to enable the 
function,  so  that  after  12  hours  of  Wind  sensor  inactivity  the 
control unit automatically sends a command for Safety upward 
movement, proceed as follows: check that the extended menu 
is  enabled  (SUN  and  RAIN  LEDs  flash  alternately),  use  the 
“SEL”  button  to  navigate  to  WIND  SPEED  LED  when  flashing 
and  press  the  “SET”  button:  the  WIND  SPEED  LED  lights  up 
and programming is complete. Repeat the procedure to restore 
the previous configuration.

 

E) SUN SENSOR  (Sun control movement inversion): 
The  control  unit  is  supplied  by  the  manufacturer  with  a  Sun 
Control = Down command association, that is to say when the 
Sun sensor detects sunlight, the control unit sends a command 
for downward movement. If you want the control unit to send a 
command  for  upward  movement  when  sunlight  is  detected  by 
the  Sun  Sensor,  proceed  as  follows:  check  that  the  extended 
menu  is  enabled  (SUN  and  RAIN  LEDs  flash  alternately),  use 
the “SEL” button to navigate to SUN SENSOR LED when flash-
ing and press the “SET” button: the SUN SENSOR LED lights 
up and programming is complete. Repeat the procedure to re-
store the previous configuration.

 

 
F) RAIN SENSOR  (Rain command movement inversion): 
The  control  unit  is  supplied  by  the  manufacturer  with  a  Rain 
Control  =  Up  command  association,  that  is  to  say  when  the 
Rain sensor detects rain, the control unit sends a command for 
upward movement. If you want the control unit to send a com-
mand  for  downward  movement  when  rain  is  detected  by  the 
Rain  sensor,  proceed  as  follows:  check  that  the  extended 
menu  is  enabled  (SUN  and  RAIN  LEDs  flash),  use  the  “SEL” 
button  to  navigate  to  RAIN  SENSOR  LED  when  flashing  and 
press the “SET” button: the RAIN SENSOR LED lights up and 
programming is complete. Repeat the procedure to restore the 
previous configuration.

 

 

R

ESET

 

To reset the default configuration of the control unit, press the 
SEL  and  SET  buttons  simultaneously;  all  indicator  LEDs  will 
switch on and then off again immediately. 

 