To enable the extended menu functions proceed as follows:
press and hold the SET button for 5 seconds; the SUN and
RAIN LEDs will start flashing alternately. the user then has 30
seconds in which to select the extended menu functions using
the SEL and SET buttons. After 30 seconds the control unit
returns to the main menu.
---------------------- EXTENDED MENU -----------------
Reference LED LED Off LED On
A) CODE remote PGM = OFF remote PGM =
ON
2) SENS. CODE Wired sensor Test = OFF Wired sensor Test =
ON
C) T. MOT. Aut. movement lock = OFF Aut. movement lock =
ON
D) WIND SPEED Safety upward = OFF Safety upward = ON
E) SUN SENSOR SUN inversion = OFF SUN inversion = ON
F) RAIN SENSOR RAIN inversion = OFF RAIN inversion = ON
G) SUN Flashing beacon ON/OFF
H) RAIN Flashing beacon ON/OFF
A) CODE
(Remote programming of radio control):
The control unit allows the transmission code to be pro-
grammed remotely, without using the SEL button on the unit
itself.
To programme a transmission code remotely, proceed as fol-
lows: send the radio control code continuously for more than
10 seconds; the control unit will enter the programming mode
as described above for the CODE LED in the main menu.
The control unit is supplied by the manufacturer with remote
programming of a transmission code not enabled; to enable
the function proceed as follows: check that the extended menu
is enabled (SUN and RAIN LEDs flash alternately), use the
SEL button to navigate to CODE LED when flashing and press
the SET button: the CODE LED lights up and programming is
complete. Repeat the procedure to restore the previous con-
figuration.
B) SENS. CODE (Wired sensor test):
The control unit can be used to check the operation of the con-
nected sensors, and to make sure the rotation direction is cor-
rect. When installing the device, we recommend the blind is
placed in an intermediate position so that you can see all con-
firmation movements during the test procedures. After check-
ing the sensors are operating correctly, you must remember to
disable the Wired sensor test.
Anemometer: manually rotate the Anemometer blades; at the
same time, the control unit will cause an upward movement
lasting 5 seconds.
Sun sensor test: expose the Sun sensor to natural or artificial
light; at the same time, the control unit will cause the SUN LED
to light up and there will be a downward movement lasting 5
seconds. Block the Sun sensor; at the same time, the control
unit will cause the SUN LED to switch off and there will be an
upward movement lasting 5 seconds.
Rain sensor test: wet the sensitive part of the Rain sensor; at
the same time, the control unit will cause the RAIN LED to light
up and there will be an upward movement lasting 5 seconds.
When you have completed the test, make sure you have dried
the sensitive part of the Rain sensor before using the control
unit in its normal operating mode.
Programming: The control unit is supplied by the manufac-
turer with the Wired sensor test disabled. If you wish to enable
the Wired sensor test, proceed as follows: check that the ex-
tended menu is enabled (SUN and RAIN LEDs flash alter-
nately), use the “SEL” button to navigate to SENSOR CODE
LED when flashing and press the “SET” button: the SENSOR
CODE LED lights up and programming is complete. Repeat the
procedure to restore the initial configuration.
Important: for information on the Wireless sensor test, please
refer to the Wireless sensor manual.
C) T. MOT. (Automatic Movement Lock):
The control unit enables the prevention of automatic move-
ments (Up / Down sun blind movements on the Sun Sensor
command or Automatic Sensors function), so that if a Stop
command is sent from a radio control during movement, the
control unit momentarily locks the Automatic movements until a
new Up or Down command is sent. The control unit is supplied
by the manufacturer with the Automatic Movement Lock dis-
abled; to enable the function proceed as follows: check that the
extended menu is enabled (SUN and RAIN LEDs flash alter-
nately). Using the “SEL” button, navigate to T.MOT LED when
flashing and press the “SET” button: the T.MOT LED lights up
and programming is complete. Repeat the procedure to restore
the previous configuration.
D) WIND SPEED (Safety upward movement):
The control unit is supplied by the manufacturer with the Safety
upward movement function disabled; if you wish to enable the
function, so that after 12 hours of Wind sensor inactivity the
control unit automatically sends a command for Safety upward
movement, proceed as follows: check that the extended menu
is enabled (SUN and RAIN LEDs flash alternately), use the
“SEL” button to navigate to WIND SPEED LED when flashing
and press the “SET” button: the WIND SPEED LED lights up
and programming is complete. Repeat the procedure to restore
the previous configuration.
E) SUN SENSOR (Sun control movement inversion):
The control unit is supplied by the manufacturer with a Sun
Control = Down command association, that is to say when the
Sun sensor detects sunlight, the control unit sends a command
for downward movement. If you want the control unit to send a
command for upward movement when sunlight is detected by
the Sun Sensor, proceed as follows: check that the extended
menu is enabled (SUN and RAIN LEDs flash alternately), use
the “SEL” button to navigate to SUN SENSOR LED when flash-
ing and press the “SET” button: the SUN SENSOR LED lights
up and programming is complete. Repeat the procedure to re-
store the previous configuration.
F) RAIN SENSOR (Rain command movement inversion):
The control unit is supplied by the manufacturer with a Rain
Control = Up command association, that is to say when the
Rain sensor detects rain, the control unit sends a command for
upward movement. If you want the control unit to send a com-
mand for downward movement when rain is detected by the
Rain sensor, proceed as follows: check that the extended
menu is enabled (SUN and RAIN LEDs flash), use the “SEL”
button to navigate to RAIN SENSOR LED when flashing and
press the “SET” button: the RAIN SENSOR LED lights up and
programming is complete. Repeat the procedure to restore the
previous configuration.
R
ESET
To reset the default configuration of the control unit, press the
SEL and SET buttons simultaneously; all indicator LEDs will
switch on and then off again immediately.