UNIT  INSTALLATION

Route the power supply cord so that it does not touch

any of the exterior components of the heater.

1.

When exiting through the wall with your type L Pellet
vent pipe, you may go straight out through a wall
thimble.  You must connect a pellet vent tee at this
point and extend the vent pipe at least 

5'

 (five feet)

vertically outside to provide good draft and allow the
gases to exit. The tee must have a clean out cap for
inspection and regular cleaning (

Figure 4)

. Horizontal

runs must be limited to 

2'

 (two feet). A wall band is

required for every 

4'

 (four feet) minimum on a vertical

run at an exterior wall.

2.

All pellet vent pipe connections including exit at the
rear of the heater should be sealed with high
temperature silicone (450

E

) or metallic duct tape. This

prevents smoke and soot leakage into the living area.
If this is not done, there is a possibility that the room
fan will pick up any leakage and blow it into the room.

AUTOLITE INSTALLATION INSTRUCTIONS

  The AutoLite System is factory installed with the only
installation requirements being the optional thermostat.

Wall Thermostat Installation:

  The wall thermostat is designed to automatically regulate
the room temperature from the control panel heat setting
to the “Off” setting based upon room temperature.
Remember to leave the control panel on the "Medium or
High" position when utilizing the wall thermostat feature.

  The following is a step by step procedure for installing the
optional wall thermostat. Note connection terminals on left
side of unit at rear (

Figure 7,8

). Use 18/2 thermostat wire

for the installation.

a.

Unplug heater from wall outlet and 12VDC power!

b.

Remove factory jump wire and hook up thermostat
wires to terminals (

Figure 7,8

).

c.

Locate thermostat approximately 10 to 12 feet from
heater or in area that requires steady temperature.

d.

Run thermostat wires from heater to thermostat
along wall or under carpet etc. and hook wires to
thermostat terminals.  On new construction you
can, of course, run wire in the walls before sheet
rock or paneling is done.

e.

Reconnect AC power.

f.

Make sure all wiring is completed before plugging
the EASYFIRE Heater back into the wall outlet.

IMPORTANT

 - Any electrical work performed on the

EASYFIRE Heater should  be done by qualified personnel.

Remote Control Thermostat Installation:

  The remote thermostat is designed to automatically
regulate the room temperature from the control panel heat
setting to the “Off” setting based upon room temperature
and placement of the remote thermostat. Remember to
leave the control panel on the "Medium or High" position
when utilizing the wall thermostat feature.

  The following is a step by step procedure for installing the
optional remote thermostat. Note connection terminals on
rear of unit (

Figure 1,2

).

a.

Unplug heater from wall outlet and 12VDC power!

b.

Mount millivolt style remote receiver box to rear of
stove using double-sided tape.

b.

Remove factory jump wire and hook up thermostat
wires to terminals (

Figure 7,8

).

d.

Reconnect AC power and follow instructions with
remote thermostat regarding set up.

IMPORTANT

 - Any electrical work performed on the

 EASYFIRE Heater should  be done by qualified personnel.

DOOR HANDLE ASSEMBLY

The door handle and latch must be assembled and adjusted
prior to the operation of the stove.

1. Position handle assembly through door and secure with

collar by sliding over shaft and tightening with allen
wrench provided (

Figure 9

).

2. Position latch on end of shaft with flat facing allen screw.

Depending on gasket, shaft will protrude approx. 1/4"
through back of latch collar. Snug allen screw.

4

Summary of Contents for EF5001U-C

Page 1: ...n approved for use with a 3 Type L Pellet Vent System or recommended 4 over 10 vertical NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or fr...

Page 2: ...ented horizontally joints shall be made gas tight by sealing with high temperature silicon or material specified by vent pipe manufacturer Failure to use listed pellet vent pipe or install it per manu...

Page 3: ...ed behind the heater before going up into the chimney This is necessary in order to remove fly ash accumulation 6 Exit termination distance to openings a 3 ft minimum above any forced air inlet locate...

Page 4: ...ve factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wires...

Page 5: ...activated and the stove operates based on the EasyFire digital control system requirements If the house AC power should quit the AutoLite system will not be available however with the optional battery...

Page 6: ...stove will begin to heat up When the stove reaches start up operating temperature it will then switch to the control panel setting and begin it s automatic operation cycle Feed Trim Adjustment Undern...

Page 7: ...ring to return against stop Figure 10 11 Once ash box is full box should be placed in a non combustible floor or on the ground well away from all combustible materials pending final disposal If the as...

Page 8: ...uires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly...

Page 9: ...place with Pyro Ceramic Glass only Refer to parts list for specifications TROUBLE SHOOTING The following scenarios are provided in order to help you locate a difficulty if the heater performs in a man...

Page 10: ...Problem Feed system jammed Solution This condition is caused by fuel contaminated with hard materials such as rocks or metal objects To correct this remove all pellets from hopper Unplug heater from a...

Page 11: ...KNOB 9 110058 HANDLE ASSEMBLY 10 120114 DOOR CATCH 11 300106 AUTOLITE SWITCH MOUNTING PLATE 12 110049 TRANSFORMER 13 120116 AUTOLITE WIRING HARNESS 14 120114 V2 MAIN CONTROL BOARD 15 120118 AUTOLITE...