GENERAL MAINTENANCE 

**BURNER  MAINTENANCE 

Repair of the burner is to be done by authorized and trained burner professionals only. 

GENERAL MAINTENANCE  AND CARE 

If the water heater is likely to be exposed to freezing weather then it should be 
winterized with anti-freeze. Circulation of an anti-freeze solution through the coil by means of 
the pumping module is the most fail-safe method and should be used. Alternate methods may 
not completely protect the components. Damage from freezing is not a warrantable item. 

Water Condition  Use  a  softener  on  your  water  system  if  local  water  is  known  to  be  high  in 
mineral content. The advantages of soft water are very beneficial: prevents scale buildup in heater 
coil,  cleans  better  with  considerably  less  detergent,  prevents  streaking  on  painted  surfaces  and 
glass when rinsing. 

**Descaling Heater Coil If heater coils develop excessive scale buildup it should be replaced 
as excessive scale in heater coil will reduce efficiency of the unit and affect recovery capacity. 

Descaling via use of acid may be hazardous and is thus not recommended. 

** Hot Water Pressure Washers Only 

Summary of Contents for MAGNUM 4000

Page 1: ...MAGNUM 4000 SERIES OWNER S MANUAL Call 1 800 315 5533 Email sales easyleen com ULTRA GOLD PLUS 3600 NEW 2014...

Page 2: ...ttempting to assemble install operate or service this pressure washer Failure to comply with the instructions could result in personal injury and or property damage CONTENTS Safety Information Introdu...

Page 3: ...NT THIS EQUIPMENT IS TO BE USED ONLY BY TRAINED OPERATORS AND MUST ALWAYS BE ATTENDED DURING OPERATION WARNING To reduce the risk of injury read operating instructions carefully before using Read the...

Page 4: ...WARNING Keep water spray away from electrical wiring All electrically powered equipment must be grounded at all times to prevent fatal electric shots Do not spray water on or near electrical component...

Page 5: ...ck Hold with both hands Hold firmly to the gun and wand during start up and operation of the machine Do not attempt to make adjustments while the trigger gun is in operation WARNING Risk of injury fro...

Page 6: ...EL Refer to the engine operation manual included with your pressure washing unit Gas Engine Oil level The engine is a 4 cycle and uses 10W30 detergent oil Refer to Glossary or engine manual Oil Fired...

Page 7: ...to PUMP adjust the burner thermostat to desired temperature turn switch to BURNER 5 Burner operation Be sure water is flowing through water heater coil before turning on burner switch Turn thermostat...

Page 8: ...se the pressure NEVER OPERATE SYSTEM AT A HIGHER P S I THAN THE MAXIMUM RATING This machine has been adjusted to operate at a specific maximum pressure as per the machine specifications Pressure may b...

Page 9: ...he chemical injector at the pump into the chemical being used 3 Turn the adjustment knob on the wand or lance to the open position OR when single lance is used black nozzle will need to be used on wan...

Page 10: ...e on to the female inlet on the pump 2 Place the open end of the hose into a wide mouthed container of full strength winter rated vehicle windshield washing fluid or Anti Freeze RATED FOR MINIMUM 40 C...

Page 11: ...omponents Damage from freezing is not a warrantable item Water Condition Use a softener on your water system if local water is known to be high in mineral content The advantages of soft water are very...

Page 12: ...0 W Non Detergent for GP Pumps and Hydraulic 68 for EK Pumps 2 Change all other components on the pump as needed GASOLINE ENGINE DAILY 1 Check oil for proper level and adjust accordingly 2 Examine the...

Page 13: ...n the pump see diagram OIL GASOLINE ENGINE Machines which are powered by gasoline engines need appropriate lubricant Use 10W30 detergent oil BURNER The burner heats the water in hot water pressure was...

Page 14: ...ur l Eau Chemical Injector Injecteur de Produits Chimique Hot Water Outlet Sortie d Eau Chaude Unloader R gulateur Pression 13 Pneumatic Tires Pneus 13 High Pressure Connector Hose Tuyau Connecteur Ha...

Page 15: ...der R gulateur Pression Hot Water Outlet Sortie d Eau Chaude Water Inlet Entr e pour l Eau EK Pump Pompe EK High Pressure Connector Hose Tuyau Connecteur Haute Pression Pressure Relief Valve Valve de...

Page 16: ...Poign e D pliante General Pump Also Available GP Pompe General Pump Aussi Disponible GP Type of Oil needed for Pumps EK Pump Hydraulic 68 650ml GP Pump SAE 30 Non Detergent Type d Huile pour les Pomp...

Page 17: ...properly or damaged Make sure you have the right nozzle size Check the pressure of the pump with a pressure guage and adjust to desired pressure If you cannot reduce the pressure replace the unloader...

Page 18: ...ough the swtich consult a professional for this if you do not know how to do this properly as you can get severly injured by the electrical current connected to your machine If current properly flows...

Reviews: