14
Eastwood Technical Assistance: 800.343.9353 >> [email protected]
PROBLEM
CAUSE
CORRECTION
Pump does
not run when
switch is
turned on
No power to
the Eastwood
Elite TIG Torch
Water Cooler
Check the local 120 VAC power connection.
Check for tripped circuit breaker.
Reset if necessary.
Check for tripped GFCI on Plug of Power Cord.
Press TEST Button then Press RESET Button.
Torch be-
comes hot
during use
GFCI has
tripped, Pump
not running
Check for tripped GFCI on Plug of Power Cord.
Press TEST Button then Press RESET Button.
Check for tripped circuit breaker.
Reset if necessary.
Hose has be-
come pinched
or kinked, cool-
ant not flowing
Check for pinched or kinked hose & correct issue.
Coolant
temperature
has exceeded
125°F
Stop welding and allow coolant to cool or replace
coolant according to the ADDING COOLANT
MIXTURE section of these Instructions.
Ice may be added to the Reservoir to allow
welding to continue however the coolant mixture
ratio will be compromised and should be replaced
after completion.
Coolant leak at
Hose fittings
Hose not fully
installed on
Brass Fitting
Push Hose fully over all barbs of brass fitting.
Hose stretched
where it fits
over Brass
Fitting
Cut 1” [25mm] from end of hose to remove bell
then re-install Hose over Fitting.
Foul odor and
debris in Cool-
ant
Bacteria and
or fungus has
grown in the
coolant
Unplug and drain coolant. Refill according to the
ADDING COOLANT MIXTURE section of these
Instructions.
TROUBLESHOOTING