background image

© Copyright 2018 Easthill Group, Inc.     6/18     Instruction item #31469Q     Rev 4

If you have any questions about the use of this product, please contact 

The Eastwood Technical Assistance Service Department: 800.343.9353  >>  email: [email protected]

PDF version of this manual is available at eastwood.com

The Eastwood Company     263 Shoemaker Road, Pottstown, PA 19464, USA 

800.343.9353     eastwood.com

PROBLEM

CAUSE

CORRECTION

Inverter Turns 

Off While  

in Use

Overload

Turn off all devices and determine which device 

is causing the overload situation. Reduce load to 

less than rated power.

Internal 

Overheating

Allow Inverter to cool for a minimum of 30 

minutes. Ensure the cooling fan is not blocked  

and the Inverter has ventilation.

No Output 

Voltage

Low / High 

Input Voltage

Ensure input voltage is within the specified range.

Loose / 

Improper 

Connections

Ensure all connections are correct and tight.

Incorrect 

Output Voltage

Incorrect Input 

Voltage

Ensure input voltage is within the specified range.

Inverter 

Cannot  

Power Load

Excessive Load

Reduce load level.

Power Cable 

Undersized

Ensure power cables are appropriately sized.

Starting 

Wattage of 

Appliance is 

Too High

Reduce load from other devices or change 

appliance.

TROUBLESHOOTING

Summary of Contents for 31464

Page 1: ...AUTOMOTIVE POWER INVERTERS INSTRUCTIONS Item 31464 31465 31800 ...

Page 2: ...e Range 9 5 16v DC Output Voltage 120v Output Frequency 60Hz Output Wave Form Pure Sine Wave THD 3 Efficiency 90 USB Output 5v DC Max 1A 5v DC Max 2 1A Input Over Voltage Shutdown 16v DC 0 5v Input Under Voltage Shutdown 9 5v DC 0 5v Input Under Voltage Alarm 9 8v DC 0 3v Over Temperature Protection 65 C 5 C Overload Protection 1200w 200w 2250w 250w 3300w 300w Overload Backup Fuse Yes No Load Curr...

Page 3: ...s electrical system This inverter is an automotive accessory It is not designed and has not been evaluated to be used with a buildings electrical system Improper application may create a fire or shock hazard Install in a dry well ventilated area indoors This power inverter is not intended for marine or under hood applications Keep all combustible materials and gasses away from the power inverter T...

Page 4: ...e of a gasoline power boat or near propane tanks Do not use the Inverter in an enclosure containing automotive type lead acid batteries These batteries unlike sealed batteries vent explosive hydrogen gas which can be ignited by sparks from electrical connections While this power inverter does output a true sine wave some sensitive electronic equipment such as medical equipment may not operate corr...

Page 5: ... Lugs on the back of the Inverter Connect the Negative DC Power Cable to the 12V power source Connect the Positive DC Cable to the 12V power source A fuse must be installed on the Positive Cable as close to the DC power source as possible See the Specifications Table in this Instruction Manual for the fuse size The Power Inverter has a Ground Terminal on the Rear Panel marked The Ground Terminal m...

Page 6: ... 4 1400 2300 Miter Saw 10 1800 1800 Belt Sander 1200 2400 Air Compressor 1 4 HP 970 1600 Outdoor Light String 250 0 Cell Phone Charger 25 0 Inflator Pump 50 150 Microwave 1000w 1000 1000 Coffee Maker 1000 0 Mini Fridge 350 1100 Refrigerator 700 2200 Flat Screen TV 200 0 DETERMINING POWER CONSUMPTION Required wattage can be determined by multiplying voltage and current draw Certain appliances such ...

Page 7: ...rformed before each use Check tightness of all connections Check power cables and ensure that they are in good shape Ensure all 120 volt devices are turned off before turning on inverter After each use wipe inverter clean with a dry cloth to prevent dust build up To prevent damage do not attempt to power a device or a combination of devices that require more than the rated output of the inverter I...

Page 8: ...g the overload situation Reduce load to less than rated power Internal Overheating Allow Inverter to cool for a minimum of 30 minutes Ensure the cooling fan is not blocked and the Inverter has ventilation No Output Voltage Low High Input Voltage Ensure input voltage is within the specified range Loose Improper Connections Ensure all connections are correct and tight Incorrect Output Voltage Incorr...