PREPARATION FOR USE

•  Open the battery cover by removing the small Phillips screw at the right side rear of the unit.
•  Insert two CR2032 batteries with the “positive (+)” sides facing outward
•  Insert the square drive adapters as required (1/2” or 3/8”)

TURNING THE TOOL ON / OFF

1.

  Press           button to turn unit on, and the display shows “0000” on the screen.

BATTERY SAVING FEATURES

The Torque Adapter will turn off automatically with inactivity after 4 minutes.

PROGRAMMING SETTINGS

1.

  Press and hold           button for 2 seconds for selecting units between lb/ft, lb/in, kg.m, N.m 

2.

   Press           button to enter the setting. The display shows 

“SET”

 on the screen. After 2 sec-

onds, “0000” or the last programmed value will be shown on display, and the left fi rst digit will 
start fl ashing, press           button to zero the reading, or press the           button to increase the 
value. When the desired value is selected, press           

to select the next numeric place to 

the right.

 Example: for a torque setting of 

75 lb/ft

, the display should read 075.0. 

NOTE:

 Even though the torque value can be set to 9999, do not exceed the rated maximum range. 

3.

   Once the target torque is set, press the           button to memorize and exit setting mode.

NOTE:

1.

  “Erro” (for ERROR will show on the display when the pre-set torque value exceeds 100% of the 

maximum torque value. After 1 second, the display returns to torque Measurement Mode.

2.

  After pressing the “+” button to access the torque setting mode, without any activity after 6 

seconds, the display will return to Measurement Mode.

TRACK / PEAK MODE SETTING

1.

 

“TRACK”

 is the default mode when the Torque Adapter is turned on.

2.

  Press and release           button to shift into 

“ PEAK”

 mode. 

“PEAK”

 appears on the left side of 

the display.

3.

 In 

“TRACK”

 mode: the display shows the reading in real time during the torquing process.

4.

 In 

“PEAK”

 mode:  The maximum value reached during use will be saved and the value is 

shown steadily on the display for approx. one second. After that, the value changes to fl ashing 
and you can continue directly to the next application 

or

 press the           button to zero the 

value, then continue to the next application.

TURNING THE DISPLAY ILLUMINATION ON / OFF

1.

  The display illumination can be turned on prior to or after programming the torque.

2.

  In order to do this, press and hold the           button for 2 seconds.

OPERATING THE TORQUE ADAPTER

1.

  Always slowly and steadily 

PULL

 to gradually build torque. Avoid quick jerky movements.

2.

  When you approach the programmed torque value 

the buzzer will sound and the RED light 

will fl ash.

3.

  When close to (within 2% of) the programmed value, 

the buzzer will emit a quicker sound 

and fl ash sequence.

4.

  When the programmed torque has been achieved, the buzzer will emit a 

continuous tone and 

the RED light will steadily illuminate.

 

NOTE: 

When the force is applied counter-clockwise, the display will show a minus (-) sign in the

left side of screen. 

NOTE:

1.  NEVER USE THE TORQUE ADAPTER WHEN THE BATTERIES ARE LOW. THE ACCURACY OF 

READINGS WILL BE AFFECTED.

2.

  The display will not show a reading until the applied force has exceeded 10% of full scale.

3.

 

“- - - -”

 will be shown on the screen, when applied torque has exceeded 5% of the maximum 

of torque value. (See specifi cations).

Summary of Contents for 13624

Page 1: ...ADAPTER INSTRUCTIONS Part 13624 IMPORTANT Please read these instructions thoroughly and carefully before operation The instructions will provide you with important information regarding operation warnings and safety precautions ...

Page 2: ...to power off feature saves batteries SPECIFICATIONS Drive 1 2 square drive 12 5 mm Measuring Range 15 148 lb ft 2 20 kg m 177 1770 lb in 20 200 N m Accuracy 2 of reading 10 to 100 of full scale Display Resolution 1 Operating voltage 6V 2 2032 batteries supplied Operating temperature 32 F 104 F 0 40 C Units of measurement lb ft lb in kg m N m FUNCTION KEYS A Power ON OFF button B Enter the setting ...

Page 3: ...out any activity after 6 seconds the display will return to Measurement Mode TRACK PEAK MODE SETTING 1 TRACK is the default mode when the Torque Adapter is turned on 2 Press and release button to shift into PEAK mode PEAK appears on the left side of the display 3 In TRACK mode the display shows the reading in real time during the torquing process 4 In PEAK mode The maximum value reached during use...

Page 4: ...eep away from strong magnetic fields Never hold or operate the unit with wet or greasy hands Never apply torque when the tool is turned off or permanent damage can occur Periodic re calibration may be necessary to maintain accuracy Check that the Torque Adapter capacity matches or exceeds each application before proceeding Verify the calibration of the Torque Adapter if you know or suspect its cap...

Page 5: ...stions about the use of this product please contact The Eastwood Technical Assistance Service Department 800 544 5118 email techelp eastwood com The Eastwood Company 263 Shoemaker Road Pottstown PA 19464 USA US and Canada 800 345 1178 outside US 610 718 8335 Fax 610 323 6268 eastwood com ...

Reviews: