background image

1

APPLICATION

The NEVERCOLD™ circulators are designed to deliver hot water instantly at the point 

of use (under sink).  Water savings can be as great as 12,000 – 15,000 gallons per 

year with 4-5 taps in a home. NEVERCOLD™ circulator is designed to be user friendly, 

reliable and to produce a professional installation.

WARNING:

 Risk of electric shock. The NEVERCOLD™ kits are supplied with a 

grounding conductor and grounding type attachment plug. To reduce the risk of 

electric shock, be certain that it is connected only to a properly grounding type 

receptacle.

WARNING:

 When installing NEVERCOLD™ observe all applicable electrical and 

plumbing codes.

WARNING:

 To avoid electrical shock, disconnect power prior to connecting or 

disconnecting NEVERCOLD™.

WARNING:

 Risk of electric shock. NEVERCOLD™ has not been investigated for use in 

swimming pool or marine areas.

WARNING:

 NEVERCOLD™ is acceptable for indoor use only. Employer uniquement a 

l’interieur.

CAUTION:

 NEVERCOLD™ has been evaluated for use with water only. The suitability 

of NEVERCOLD™ for use with liquids other than water is the responsibility of the end 

user.

For optimum reliability and performance please follow the installation instructions 

outlined in this manual.

NOTE: Please note that this is not an anti-scald unit. There may be some warm water 

in the cold water line under the sink where the circulator is installed. Once the cold 

water line is opened, the warm water will disappear in a short time. (Longer hot water 

lines may result in longer time for hot water to reach the sink.)

70601

Summary of Contents for NEVERCOLD 70601

Page 1: ...FROM USER MANUAL INSTALLS UNDE SINK...

Page 2: ...T FROM HEAT SOURCE SHOWER SINK Get hot water comfort at every faucet Save time no more waiting for hot water Save hot water up to 12 000 gallons a year Save energy save on utility and sewer fees GO GR...

Page 3: ...shock disconnect power prior to connecting or disconnecting NEVERCOLD WARNING Risk of electric shock NEVERCOLD has not been investigated for use in swimming pool or marine areas WARNING NEVERCOLD is...

Page 4: ...ich opens to at least 1 Undersink Installation Instructions Hot Water Supply Cold Water Supply Tee Hot Hot Union Tailpiece Gasket Union Tailpiece Gasket Red Marking Warning Red mark on fitting must be...

Page 5: ...ves Fig 1 and disconnect the flexible hoses attached to each valve by turning the nut at the end of the hoses counter clockwise Fig 2 3 Install one Tee at each valve Connect female port of the Tee to...

Page 6: ...IDE THAT IS OPPOSITE DIRECTION OF ARROW OF THE PUMP You will need two pipe wrenches that open to at least 1 1 2 inches Firmly tighten the two union nuts to avoid leaks Do not install the pump upside d...

Page 7: ...HE COLD VALVE IS CONNECTED TO THE DISCHARGE SIDE ATTACHED TO THE COLD VALVE IS CONNECTED TO THE DISCHARGE SIDE THAT IS THE SIDE THE ARROW IS POINTING TO OF THE PUMP Fig 6 THAT IS THE SIDE THE ARROW IS...

Page 8: ...oon and 13 to 24 on the clock indicates 1PM to midnight 2 To set the time that the pump will operate move all the tabs outward during the time period Fig 1 Example To set ON at 7 00AM and OFF at 10 00...

Page 9: ...idge sleeve with opposite hands and pulling apart Clean rinse the two parts and re assemble Follow the procedure under Replacing Cartridge Assembly It is also recommended to flush the system REPLACING...

Page 10: ...This warranty shall be invalidated by any abuse misuse misapplication or improper installation or maintenance of the product by any abuse misuse misapplication or improper installation or maintenance...

Page 11: ...GN INSTANT HOT WATER Built in timer only runs pump when it is set to run Can be installed in less than 30 minutes Conserves up to 12 000 gallons of water per year Save time No more waiting for hot wat...

Reviews: