Eastman Heavy Machinery
24
Chapter 5 – Pre-operation Inspection
Item
Inspect For
Ok
Operator’s Manual
In manual holder
Electrical System
Battery fluid level
Proper level
Battery terminals
Clean, connectors tight
Battery charger
Proper operation
Cables and wiring harness
No wear or physical damage
Hydraulic System
Fluid level
Between full and add marks
Hoses, tubes, and fittings
No leaks
Free-wheeling valve
Fully closed
Tires and Wheels
Good condition
Ground Strap
In place and securely fastened
Lower Control Station
Operating controls
Proper operation
Emergency stop
Shuts off lower controls
Lowering alarm and interrupt
Sounds when platform lowers
Pothole Protection Interlock
Proper operation
Emergency Lowering
Proper operation
Safety Prop
No damage or deformation
Flashing Light
Proper operation
Structures
Weldments
Welds intact, no damage or deformation
Slide pads
In place, no damage or deformation
Fasteners
In place and tight
Upper Control Station
Guardrail system
Welds intact, no damage or deformation
Platform extension
Proper operation
Operating controls
Proper operation
Emergency stop
Shuts off upper controls
Horn
Sounds when activated
Lowering alarm and interrupt
Sounds when platform lowers, proper
operation
Drive motion alarm
Sounds when aerial platform moves
Battery condition indicator
Proper operation
Placards and Decals
In place and readable