26 Adjustments
Read these simplified instructions before operating.
Important:
Verify that the Dual Voltage Switch is set to the correct AC
line input voltage, “115” or “230.”
•
Install the correct Plug-In Horsepower Resistor® according to input voltage and
motor horsepower.
•
Install proper size Armature Fuse.
•
Install Auxiliary Heatsink on controls used with motors rated above ¾ HP on
120V AC, and 1-½ HP on 240V AC.
•
Recheck connections: AC line to L1 and L2; armature to A+ and A-; and field
(Shunt motor only) to F+ and F-. Connect ground via ground screw. (Note: if
motor runs in improper direction, reverse armature leads.)
•
Nominal trimpot settings are as follows (expressed in % of full clockwise
rotation):
MIN (minimum speed)
15%
MAX (maximum speed)
60%
IR (IR compensation)
15%
CL (current limit/torque)
65%
ACCEL (acceleration start)
20%
DECEL (deceleration)
20%
For more detailed information refer to instructions in the previous pages or refer to the
KBMM™ Installation and Operation Manual, provided by the D.C. board manufacturer