~ 63 ~
Chapter 11 Appendixes
Explanation of term
Name
Description
ANTI-TIED
The inverter is not allowed to supply the power to the grid
GRID-TIED
The inverter is allowed to supply the power to the grid, as opposed to
ANTI-TIED
AC CHA.
The inverter is allowed to receive the power from the grid for charging the
battery.
TIMER.SWITCH
The inverter may be set to operate in different operation modes in different
time periods.
SOC
State of charge, also called remaining capacity, refers to the ratio of
current available carrying capacity to the carrying capacity in full charging
status, expressed in percentage, ranging from 1% to 100%.
BMS
Battery manager system
EOD
In the photo voltaic energy storage products of this series, the end of
discharge (EOD) refers to the voltage or SOC used for prohibit battery
discharging. When the battery voltage is less than this value, or SOC is
less than the lower limit, the inverter will give a “battery under-voltage”
alarm and prohibit battery discharging.
DOD
Depth of charge (DOD) refers to one method for the energy storage
inverter to reflect the depth of battery discharge. Another method is SOC.
Equalized
charging
Refers to the constant current charging stage, in which the charging
voltage will gradually increase until it reaches the equalized charging
voltage value.
Equalized
charging voltage
Refers to the target voltage value achieved by constant current charging,
which can be set within the specified range.
Floating charge
Refers to the constant voltage charging phase, in which the charging
current gradually decreases to maintain the battery voltage at the set
floating charging voltage value.
Floating charge
voltage
Constant voltage charge voltage, which can be set within a specified
range
Domestic load
Refers to the load that is connected between the "AC input" port of the
inverter and the CT/kilo-watt-hour meter accessory, the power of which is
not restricted by the inverter.
Backup load
Refers to the load connected to the "load output" port of the inverter. The
power of the load is limited by the carrying capacity of the inverter when it
operates in off-grid mode.
BACK-UP
Silk screen may be "load output" or "EPS"; here, they have the same
meaning, and refer to the "off-grid load" port.