1
1 Basic Introduction
1.1 Function
It allows you to measure DC V, DC mV, resistance ,TC and RTD.
Outputs resistance, simulation of TC and RTD.
Thermocouple(TC) measurement provides cold-junction compensation.
Manual stepping, automatic stepping, 0
~
100% phase step and ramp output.
Super-strong
protection
:
The waterproof grade is IP67. Automatic protection
against the signal terminals connect to the 220V.
Support for PC communication
1.2 Summary of Source and Measure
Functions
Function
Measure
Source
DC V
0
~
30V
Not available
DC mV
0
~
120mV
0mV
~
100mV
Resistance
0
~
3200Ω
0
~
3200Ω
RTD
Pt100, Pt1000, Cu50, Cu100
Pt100, Pt1000, Cu50, Cu100
TC
E,J,K,T,B,R,S,N
E,J,K,T,B,R,S,N
Others
Stepping output, ramp, phase step output, user-defined range