Parameter setting interface operation instructions: 1. Press [Shift] + [
◀
] (Menu) in the main
interface of the scan test to enter the scan setting interface; 2. Select the operation item by
rotating the knob; 3. Press the [Enter] key for non-numeric parameters. Switch the setting
options; 4. For numeric parameters, press [Enter] to enter the editing mode, use the arrow
keys to select the corresponding number of digits, then rotate the knob to adjust the value,
[Enter] or [Shift] + [
▶
] (Esc) Exit editing; 5. Press [Shift] + [
▶
] (Esc) to return to the
previous interface.
Test interface operation instructions: Press the corresponding [On1], [On2] to start or
close the mode.
Fig 2.7.1 Scan Test Set Interface
Fig 2.7.2 Scan Test Interface
2.8 Battery Test Operation
The battery test function is commonly used to detect the discharge performance of the battery.
The electronic load can be operated in a constant current or a constant resistance mode,
which can conveniently determine the discharge capacity of the battery.
Parameter setting interface operation instructions: 1. Press [Shift] + [
◀
] (Menu) in the
battery test main interface to enter the battery setting interface; 2. Select the operation item
by rotating the knob; 3. Press the [Enter] key for non-numeric parameters. Switch the setting
options; 4. For numeric parameters, press [Enter] to enter the editing mode, use the arrow