31
30
EASTOAK.COM
FIRE PIT TABLE
OWNER’S MANUAL
ASSEMBLY INSTRUCTION
(Installation Location)
ASSEMBLY INSTRUCTION
(Installation Location)
• All leak test should be performed outdoors.
• Extinguish all open flames before testing.
• DO NOT smoke when perform leak test.
• DO NOT use the product until all connections have been tested and do not leak.
• Leak test should be perform once a year or after LPG cylinder or any gas
systemparts replaced, whichever come first.
1. Mix half part liquid detergent and half part water to make leak check solution.
2. Apply leak check solution on every gas system joints and connections.
3. Turn ON the LPG cylinder valve to check any possible leak.
WARNING
If bubbles appear at any connection, there is a leak.
1. Turn LPG cylinder valve OFF.
2. If there is a leak, disconnect the connection and reconnect, then perform another
leak test. lf bubbles continue to appear after several attempts, you should replace
the hose or cylinder valve.
If NO bubbles appear, the connection is secure.
• DO NOT use the appliance if there is a leak.
• Contact a qualified service technician if attempts to stop the leak(s) are unsuccessful.
• Until leak problem is corrected, LPG supply must be shut o ffat the cylinder valve or
the LPG cvlinder must be disconnected and removed from the appliance.
• Inspect gas hose before use. Hose assembly must be replaced if there is evidence
of excessive abrasion, wear, or damage.
Before operating the appliance:
• Ensure the gas line is properly connected and there is no holes or damage to
the hose.
• Ensure there are no leaks (see page 30 for how to check for leaks).
• Ensure the LPG cylinder valve and all control knobs are switched to the
“OFF” position.