166119
8/31/2006
59
5 Appendix
5.1 Factory Default Configuration (Null Configuration)
Systems are shipped with a factory-default configuration to provide a starting point for the
operator to configure the system and establish limited, basic functionality of the hardware.
The factory default configuration may be restored in working configuration memory at any
time by executing the Null
Configuration Reset
command.
Table 14 summarizes the settings stored in systems upon shipping to the customer.
Composite Port
All Channels / Ports (1-16)
State
Disable
De-allocated
Rate
768Kbps
0 (No Clock)
Port Type
Off
RS-232 Async, 10bits
Loops
None
None
Timing Source
RxC (f/DCE)
N/A
TxD Clock
TxC
TxC
DCD Source
N/A
Follow Sync
TxCE Output
Disabled
N/A
Password
“default”
Table 14 – Nx8-DualMUX Factory Default (Null) Configuration Settings
Summary of Contents for Nx8- Dual Composite MUX High-Speed 16-Port TDM...
Page 2: ......
Page 6: ...166119 8 31 2006 2...
Page 32: ...166119 8 31 2006 28...
Page 38: ...166119 8 31 2006 34...
Page 61: ...166119 8 31 2006 57...
Page 62: ...166119 8 31 2006 58...