2..10      CASCADING OR CONCATENATION

The DMM-X21 supports cascading by utilizing DB-15 Male-to-Male straight through
shielded cables. 

Subchannel Port 1

 should be used as the concatenation port.

2.8      MANUAL DTE/DCE REMOVAL

The DMM-X21 incorporates circuitry that will (when enabled) 

manually

 remove a

streaming terminal from service.  A streaming terminal is defined as a terminal that has
Control (C) continually 

high

.  With Anti-streaming disabled, the associated streaming

DTE will 

NOT

 illuminate a Yellow LED on the front of the DMM-X21.  If the automatic

anti-streaming circuitry is disabled and a streaming condition occurs, the other DTE
devices will be blocked from accessing the communications link.  To correct this
condition, simply push the associated 

push-button switch

 for the subchannel that is

streaming.  All other DTE's will now continue to be serviced by the DMM-X21.
However, you still need to fix the offending DTE or DCE device that has Control (C) or
Indicate (I) continually raised.

2.9      FALL BACK TIMING

The DMM-X21 incorporates circuitry that allows the user to provide 

Fall Back Timing

 to

the network.  The circuity allows the user to enable or disable this funtion via Dip
Switch.  To enable fall back Timing, go to the dip switch marked S11 and move position
8 to ON.  This will provide Port 1 as the main timing source.  If Port 1 clock fails, the unit
will automatically switch to Port 2 as the timing source.  If Port 2 fails, the unit will
automatically fall back to internal clock as the timing source.  If Port 1 clock returns to
service, the unit will automatically switch back to Port 1 timing.

East Coast Datacom, Inc.  DMM-X21 OPERATIONS MANUAL

Page 5

D
M
M

D
M
M

MODEM

CONNECT TO MASTER PORT

CONNECT TO PORT 1

DB-15 CABLE

CASCADING DIAGRAM

OR F.E.P.

Summary of Contents for DMM-X21

Page 1: ...Page 5 2 14 FIFO GENERAL OPERATION J14 Page 5 2 13 DCE DTE SWITCHES Page 5 2 12 CONTROL C LEAD PORTS 1 4 Page 5 2 11 INDICATE I LEAD PORTS 1 4 Page 4 2 10 CASCADING OR CONCATENATION Page 4 2 9 FALL B...

Page 2: ...h 1997 Manufactured By East Coast Datacom Inc FOR TECHNICAL SUPPORT CALL East Coast Datacom Inc 571 Haverty Court STE N Rockledge FL 32955 USA TEL 800 240 7948 or 407 637 9922 FAX 407 637 9980 Email e...

Page 3: ...s in materials and workmanship The warranty period shall be three 3 years from the date of shipment E C D s sole obligation under its warranty is limited to the repair or replacement of defective equi...

Page 4: ...In applications where the master port and the selected port provide their own clocks data is clocked into the buffer at the receive clock rate of the active port and clocked out using the master port...

Page 5: ...te in union with individual Green subchannel port activity LEDs and identify Transmit and Receive data transmissions Yellow LEDs provide the user with a visual indication of a streaming DTE ref 2 6 Po...

Page 6: ...ANTI STREAMING 2 6 1 AUTOMATIC REMOVAL The DMM X21 incorporates circuitry that will when enabled automatically remove a streaming DCE or DTE from service A streaming terminal is defined as a terminal...

Page 7: ...subchannel that is streaming All other DTE s will now continue to be serviced by the DMM X21 However you still need to fix the offending DTE or DCE device that has Control C or Indicate I continually...

Page 8: ...hronous clocks Mode B FIFOs self center after overrun or overflow for isochronous clocks 2 12 CONTROL C LEAD The DMM X21 has internal jumpers for Normal or Forced Control C This option will allow Cont...

Page 9: ...20mm 320ma 315ma Fuses For 220 VAC 10 operation the unit is equipped with slow blow 5 x 20mm 160ma Fuses Spare fuses may be purchased by calling East Coast Datacom or by calling the fuse manufacturer...

Page 10: ...ed it will be necessary to remove the top cover of the DMM X21 Remove the AC Power source or Disconnect the AC Power before servicing the unit Removal of the top cover is accomplished by using a small...

Page 11: ...SIGNAL TIMING B 13 X INDICATE B 12 X RECEIVE B 11 X CONTROL B 10 X TRANSMIT B 9 GROUND 8 X BYTE TIMING A 7 X SIGNAL TIMING A 6 X INDICATE A 5 X RECEIVE A 4 X CONTROL A 3 X TRANSMIT A 2 SHIELD 1 FROM...

Page 12: ...4 2 FACTORY DEFAULT CHART East Coast Datacom Inc DMM X21 OPERATIONS MANUAL Page 10 ON 1 2 3 4 5 6 7 8 9 1 0 DMM X21 FACTORY DEFAULT SWITCH GUIDE...

Page 13: ...ormation Service 5285 Port Royal Road Springfield VA 22161 Telephone 703 487 4650 ISO Outside the United States International Organization for Standardization Central Secretariat 1 rue de Varembe CH 1...

Page 14: ...Power Source 100 120 to 200 220VAC 10 50 60Hz 0 16 0 08A external 110 220 volt select switch IEC Power Inlet 2 5mm Fuses Environmental Operating Temperature 32 to 122 F 0 to 50 C Relative Humidity 5 t...

Reviews: