background image

4.2      FACTORY DEFAULT CHART

DMM-4DC OPERATIONS MANUAL

Page 9

MASTER PORT

DCE

DTE

PWR

TXD

RXD

ON

1 2 3 4 5 6 7 8

SW9

SW10

FULL BAUD RATE SELECT

SW11

76800

38400

19200

9600

4800

2400

1200

600

5

ON

OFF

ON

OFF

ON

OFF

ON

OFF

6

ON

ON

OFF

OFF

ON

ON

OFF

OFF

7

ON

ON

ON

ON

OFF

OFF

OFF

OFF

ASYNC / SYNC SELECTION 

SW11

ASYNC

SYNC

9

ON

OFF

NOT USED

SW11

RESERVED FOR

FUTURE USE

10

RTS/ CTS DELAY 

SW11

0 MS

5 MS

10 MS

20 MS

1

ON

ON

OFF

OFF

ANTI-STREAM

2

ON

OFF

ON

OFF

SW11

DISABLE

5 SEC.

10 SEC.

60 SEC.

3

ON

ON

OFF

OFF

4

ON

OFF

ON

OFF

INT. TIMING(1,2)

48V RTN(+)

PORT 1

DCE

DTE

SW1

SW2

PORT 2

DCE

DTE

SW3

SW4

PORT 3

DCE

DTE

SW5

SW6

PORT 4

DCE

DTE

SW7

SW8

9 10

8

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

3/4 BAUD RATE SELECT

SW11

57600

28800

14400

7200

3600

1800

900

450

5

ON

OFF

ON

OFF

ON

OFF

ON

OFF

6

ON

ON

OFF

OFF

ON

ON

OFF

OFF

7

ON

ON

ON

ON

OFF

OFF

OFF

OFF

8

ON

ON

ON

ON

ON

ON

ON

ON

ACTIVE

INDICATORS

STREAM

INDICATORS

SUB-CHANNEL

ENABLE / DISABLE

SWITCHES

EXT. TIMING(2,3)

JP1

 (PORT 1)

JP5

NORMAL CTS

FORCED  CTS

ENABLE CONTROL(1,2)

JP2

 (PORT 2)

NORMAL CTS

FORCED  CTS

JP3

 (PORT 3)

NORMAL CTS

FORCED  CTS

JP4

 (PORT 4)

NORMAL CTS

FORCED  CTS

S11

** BOLD TEXT DENOTES FACTORY DEFAULT

DMM-4DC FACTORY DEFAULT / SWITCH GUIDE

PORT 1 

TELCO

TIMING(2,4)

JP9

 (PORT 4)

JP6

 (PORT 1)

JP7

 (PORT 2)

JP8

 (PORT 3)

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

1

2

3

4

DISABLE CONTROL(2,3)

ENABLE CONTROL(1,2)

DISABLE CONTROL(2,3)

ENABLE CONTROL(1,2)

DISABLE CONTROL(2,3)

ENABLE CONTROL(1,2)

DISABLE CONTROL(2,3)

48V NEG(-)

315 ma FUSE

315 ma FUSE

F1

F2

48V NEG(-)

48V RTN(+)

J6

Summary of Contents for DMM-4DC

Page 1: ...5 2 13 DCE DTE SWITCHES Page 5 2 12 NORMAL OR FORCED CLEAR TO SEND CTS PORTS 1 4 Page 5 2 11 ENABLE CONTROL PORTS 1 4 Page 4 2 10 CASCADING OR CONCATENATION Page 4 2 9 UNEXPLAINED STREAMING TERMINALS...

Page 2: ...MIXING MODULE 48VDC POWER SUPPLY January 22 2002 Manufactured By East Coast Datacom Inc FOR TECHNICAL SUPPORT CALL East Coast Datacom Inc 245 Gus Hipp Blvd STE 3 Rockledge FL 32955 TEL 800 240 7948 or...

Page 3: ...nt is free from any defects in materials and workmanship The warranty period shall be three 3 years from the date of shipment E C D s sole obligation under its warranty is limited to the repair or rep...

Page 4: ...er is provided In applications where the master port and the selected port provide their own clocks data is clocked into the buffer at the receive clock rate of the active port and clocked out using t...

Page 5: ...g switches are provided for each DTE port for isolating or removing a streaming terminal Each DTE port has its own switch and operates independently To disable a subchannel simply push the switch A ch...

Page 6: ...TS TO CTS DELAY RTS to CTS delays of 0 5 10 and 20ms are user selectable 2 6 ANTI STREAMING 2 6 1 AUTOMATIC DTE REMOVAL The DMM 4DC incorporates circuitry that will when enabled automatically remove a...

Page 7: ...ll other DTE s will now continue to be serviced by the DMM 4DC However you still need to fix the offending DTE or DCE device that has RTS or DCD continually raised 2 9 UNEXPLAINED STREAMING TERMINALS...

Page 8: ...and DTE Slide BOTH switches to the same position to configure each of the RS 232 ports as a DTE or a DCE interface When set to DCE the RS 232 port MUST connect to a DTE device When set to a DTE the R...

Page 9: ...pect the fuses Spare fuses may be obtained by calling East Coast Datacom Replacement fuse Part 714003 or by calling Little Fuse at 312 824 3024 Part 218 315 Shurter Inc at 707 778 6311 Part 034 3112 P...

Page 10: ...more of the default settings to be changed it will be necessary to remove the top cover of the DMM 4DC Remove the DC Power source or Disconnect the DC Power before servicing the unit Removal of the t...

Page 11: ...iming DD 115 17 X Send Timing DB 114 15 Voltage 9v 10 Voltage 9v 9 X Receive Line Detector CF 109 Signal Ground AB 102 7 X DCE Ready CC 107 6 X Clear To Send CB 106 5 X Request To Send CA 105 4 X Rece...

Page 12: ...F OFF OFF OFF OFF OFF OFF 3 4 BAUD RATE SELECT SW11 57600 28800 14400 7200 3600 1800 900 450 5 ON OFF ON OFF ON OFF ON OFF 6 ON ON OFF OFF ON ON OFF OFF 7 ON ON ON ON OFF OFF OFF OFF 8 ON ON ON ON ON...

Page 13: ...1 MODEM 2 MODEM 3 MODEM 4 SET TO EXTERNAL TRANSMIT CLOCK TERMINAL TIMING MODEM SLAVE SET TO RECEIVE CLOCK SLAVE CLOCK DMM 4 CLOCKING AND SIGNAL ROUTING DIAGRAM CSU DSU TERMINAL TERMINAL DIGITAL MIXIN...

Page 14: ...4 4 USER NOTES DMM 4DC OPERATIONS MANUAL Page 11...

Page 15: ...ows normal RTS CTS handshaking or has option for Forced CTS on Ports 1 4 JP1 JP4 RTS To CTS Delay Selectable RTS to CTS delays of 0 5 10 and 20ms Front Panel Indicators Power Transmit Data Receive Dat...