3.
Installing
Installation Requirements
1. Please install the inverter(s) in places that can
avoid inadvertent contact.
2. Please install the inverter on solid/smooth
surfaces.
3. The inverter(s) should not be installed near
inflammable or explosive objects.
Installing the PE Cable
A second PE terminal is equipped at the bottom of the inverter.
Ensure the PE terminal is reliably grounded and the grounding
resistance is less than 10 Ohm.
3.2
Object
Description
1
Housing
2
M6 terminal lug with protective conductor
3
M6×16 screw SUS304
Tighten it firmly into the housing (Cross screwdriver, torque: 3Nm).
NOTICE
Proper grounding connection of the second PE terminal and the AC terminal is mandatory. NOT
properly connecting both PE will void all product warranty.
2.
Packing List
Direct
Sunlight
Rain
Exposure
Snow
Lay up
AVOID
No
Item
Type
Specifications
1
PE cable
Single-core outdoor copper cable
•
Conductor cross-section: ≥ 16mm²
2
AC Output
cable
Outdoor copper cable
•
Conductor cross-section: L/PE: 16mm²
N: 6mm²
•
Cable outer diameter: 21-51 mm
3
DC Input
cable
Standard outdoor PV cable,
PV1-F Model recommended
•
Conductor cross-section: 4-6 mm²
•
Cable outer diameter: 5-8 mm
4
Meter/DRED
Two-core outdoor shielded
twisted pair cable
•
Conductor cross-section: 0.14-1.5 mm²
•
Cable outer diameter: approx. 4-6 mm
Cable Specifications
3.1 Mounting
1. LCD&LED or LED
2. DC switch (optional)
3. PV Terminal (s)
4. COM1: Wi-Fi / GPRS
Stick(optional)
5. COM2: RS485 Terminal
6. COM3: Meter / DRED Terminal
7. AC Terminal
8. Second PE Terminal
Dimension:W×H×D=580 x 435 x 242mm
1
2
3
W
H
D
1
2
3 4
5
7
8
6
3.1.1. Use the mounting bracket as a template mark and drill holes of 10mm diameter and 70mm depth
3.1.2 Fix the mounting bracket with the screws and expansion bolts packed in mounting accessories
3.1.3 Attach the inverter to the mounting bracket
3.1.4 Check both sides of heat sink and ensure the inverter is stably attached
3.1.5 Use M5 screw (with cross screwdriver, torque: 2.5Nm) to attach the heat sink fins to the mounting
bracket
3.1.6 It is recommended to attach an anti-theft lock to the inverter
φ10mm(4X)
Deep 70mm
350mm
489mm
489mm
1000mm
Quick installation guide
EINSOLAR
36
Y
, EINSOLAR5
0
Y
1.
Product Overview
Inverter
Mounting
Bracket
Mounting
Accessories
DC Plugs
(Sealed)
AC connector
box
Meter Plug
(optional)
Wifi Stick
(optional)
Documents
*6 pairs for EINSOLAR36Y