Frequency Response
20Hz to 30kHz (Cardioid)
Polar Pattern
Cardioid or Hypercardioid
Sensitivity
FW430/C: 10mV/Pa (-40dBV/Pa)
FW430/HC: 20mV/Pa (-34dBV/Pa)
Power Requirements
24-48V Phantom, 10mA
Max Acoustic Input
145dB SPL (Cardioid); 139dB SPL (Hypercardioid)
Output
XLR-3 (pin 2+)
Min Output Load
600Ω between pins 2 & 3
Noise
20dB SPL equivalent (A weighted) [Cardioid]
16dB SPL equivalent (A weighted) [Hypercardioid]
Positioning Range
From 1.5 ft. to 7 ft. above floor level
Dimensions L x D
Stand 4.7 in. long (1.4m), Metal Base 12” (30.5cm), dia 1.1 in.
(2.7cm) high. Tripod Base footprint 23 in. (.58m) 6 in. (.15m)
high
Unit Weights
Stand 1.2 lbs. (0.54 kg), Metal Base 12.6 lbs. (5.7kg), Tripod
Base 1.6 lbs. (0.73kg)
•
20Hz to 30kHz Frequency Response
•
Near Perfect Polar Pattern Provides Uniform Frequency Response at 0°, 45°& 90°
•
Highly Versatile & Easy to Position from 10 inches to 4.7 feet high
•
Low Profile with No Visible Wires Above Floor Level
•
More Gain Before Feedback
•
Position Microphone Without Moving Stand
•
Low Handling Noise
•
Available in Cardioid & Hypercardioid
SPECIFICATIONS
FE ATURES
37 Wilton Rd. Milford, NH 03055
(603) 654-2433
[email protected] / earthworksaudio.com
If you encounter issues while using your Earthworks Audio microphone, please make sure that:
•
Your microphone is connected to an active power supply.
•
Phantom power is being supplied to the microphone.
•
Your microphone and XLR cable are well connected.
•
The microphone is positioned at an appropriate distance from the sound source.
•
External noise in your recording environment is kept to a minimum.
•
Your recording space is at room temperature and free of dust.
If your issue persists after checking, please contact us via our website.
TROUBLESHOOTING
WE'RE HERE
TO HELP
For anything else, we're a phone call or email away. Please feel free to contact us by email at
[email protected], or by phone at (603)-654-2433.