How to ensure your spreader is properly calibrated
- continued
STANDARD-OUTPUT Tray:
Make sure the drop holes in the bottom of the hopper are
FULLY OPEN
when the Rate Control handle is on #30. If the shut-off is not set correctly,
please adjust Control Rod at the Pivot to position the shut-off for
FULLY OPEN
hopper position
at #30 on the Rate Control Lever.
Calibration Adjustment
Review the Control Lever position to confirm that it is set so that the rear edge of the Lever is
resting at #30 (the stop) and the drop holes are open. If the shut-off is not properly positioned,
you will need to adjust the Control Rod at the Pivot Bracket shown below.
TIP:
If your shut-off
is not able to
OPEN
fully, loosen the bottom nut a few turns, then tighten the upper nut so that
it allows you to push the
shut-off fully open
. Next, tighten each nut so that they contact the
pivot bracket without moving it, and then carefully tighten each nut fully so they do not loosen
during use. Recheck adjustment as outlined above.
Control Lever Drag adjustment
If the Control Lever does not stay in position causing the setting rate to change without
your intervention, you can adjust the drag on the Lever by tightening or loosening the nut
shown to the right until the drag is appropriate.
If you have any questions regarding the operation or assembly of your spreader please call us at 800-294-0671 or 574-848-
7491 Monday - Friday 9:00am - 4:00pm Eastern, or visit www.earthway.com for more information
0
30
PIVOT
CALIBRATION
POINT
GAUGE &
LEVER
#0
#30
Lever
Drag
Adjustment