5

SpECIFICATIONS AND ELECTRICAL REQUIREMENTS

AppLICATION CONDITIONS

The Earthquake 5-Ton Electric Log Splitter has been designed 

as a home use model only. It is designed for operating at ambi-

ent temperatures between 40° F. and 105° F.  The log splitter 

can be stored or transported under ambient temperatures 

between -10° F. and 130° F.

SpECIFICATIONS

Model Number

w1200

Motor

120V~50Hz 

1500w Ip54

Circuit protection  

Requirements

20 Amps 

(Amperes)

Log Capacity

Diameter *

2 - 10 inches

Length

20 inches

Splitting Force

5 ton

Hydraulic pressure

2,300 psi

Hydraulic Oil Capacity

3.75 quarts

Overall Size

Length

37 inches

width

11 inches

Height

20 inches

weight

105 lb

*The diameter of the log is not indicative - a small log can be difficult 

to split when it contains knobs or a particularly tough fiber. On the 

other hand, it may not be difficult to split logs with regular fibers 

even if its diameter exceeds the maximum diameter described in the 

specifications chart.

ELECTRICAL REQUIREMENTS

Connect the main leads to a standard 110V ±10% electrical 

supply which has protection devices under-voltage, over-volt-

age, over-current, as well as a ground fault circuit interrupter 

(GFCI) or a ground fault interrupter (GFI) with a maximum 

residual current of 0.03A.

Summary of Contents for W1200

Page 1: ...ITS CUSTOMERS ORDERS IT SHALL NOT BE DISCLOSED TO OTHERS OR COPIED WITHOUT ARDISAMS SPECIFIC WRITTEN CONSENT AND SHALL BE IMMEDIATELY RETURNED UPON REQUEST MATERIAL TOLERANCE UNLESS OTHERWISE NOTED 0...

Page 2: ...operate and maintain your log splitter Congratulations on your investment in quality CONTENTS Registration 2 Safety Safety Rules 3 4 Specifications Electrical Requirements 5 Set Up and Pre Operation 6...

Page 3: ...loose clothing or jewelry that may get caught in moving parts Always wear safety goggles for eye protection Everyday glasses have only impact resistant lenses and are not effective safety glasses Warn...

Page 4: ...tdoor power equipment manufacturing Reading this manual and the safety instructions it contains will provide you with the necessary knowledge to operate this equipment safely and effectively We have p...

Page 5: ...ameter 2 10 inches Length 20 inches Splitting Force 5 ton Hydraulic Pressure 2 300 psi Hydraulic Oil Capacity 3 75 quarts Overall Size Length 37 inches Width 11 inches Height 20 inches Weight 105 lb T...

Page 6: ...tch control lever circuit breaker 10 Log pusher 6 Rubber feet 11 Log cradle 7 Rolling wheel Warning For your own safety do not connect the log splittertothepowersourceuntilthemachine is completely ass...

Page 7: ...ded SEE FIGURE 3 3 Attach safety guard lever to the top of the rolling wheel bracket with M6 1 x 12 bolts provided SEE FIGURE 3 4 Assemble the handle bars by attaching the completed handle bar assembl...

Page 8: ...two logs at the same time FREEING A JAMMED LOG 1 Release both controls 2 Once the log pusher completely stops at its starting position insert a wood wedge under the jammed log SEE FIGURE 7 3 Start the...

Page 9: ...e of dipstick on the oil drain bolt and put it back into the oil tank 7 Make sure the level of the refilled oil is between the two grooves around the dipstick 8 Clean the oil drain bolt before re thre...

Page 10: ...ERVICE TROUBLESHOOTING AND REPAIR Troubleshooting Important In case of a service problem do not send unit back to retailer Contact Ardisam Inc at 1 800 345 6007 any time monday through friday from 8 a...

Page 11: ...ric Log SplitterW1200 Check for parts online at www getearthquake com or call 800 345 6007 M F 8 5 11 W1200 MINI ELECTRIC LOG SPLITTER BREAKDOWN 17 18 9 10 11 12 27 25 26 29 13 8 7 14 15 16 6 5 4 3 1...

Page 12: ...063 Log cradle a w1200 1 13 w120062 Log cradle b w1200 1 14 w1200248 Control lever assy w1200 1 15 W1200122 WASHER M5 X 1 1 SPRLK HIGH COLLAR 2 16 W1200123 BOLT M5 8 X 16 SCH GR8 8 BLK OX F T 1 17 W12...

Page 13: ...h have not been subjected to negligent use misuse alteration accident unauthor ized parts failure to use proper fuel and oil or if repairs have been performed at non authorized service centers These w...

Page 14: ...____________ _______________________________________________________________________________________________________ ___________________________________________________________________________________...

Page 15: ...____________ _______________________________________________________________________________________________________ ___________________________________________________________________________________...

Page 16: ...k for parts online at www earthquake com or call 800 345 6007 M F 8 5 Earthquake Division of Ardisam Inc 1160 8th Avenue PO Box 666 Cumberland WI 54829 800 345 6007 Fax 715 822 2223 Email info ardisam...

Reviews: